1 No: IS-00717 – Rev. B The Wattstopper PARTITION-SENSOR uses an infrared transmitter/receiver pair to detect partition opening and closing and, in conjunction with other Architectural Dimming products, coordinates lighting and shade preset functions in areas such as partitioned meeting rooms or ballrooms. When used with the unique partitioning programming features of Design Center and the divide and combine widget on the Equinox touchscreens, the PARTITION-SENSOR allows for automation of partitioned spaces and visual indication of room lighting and shade status. Wattstopper ® Partition Sensor Installation Instructions No: IS-00717– Rev. B PARTITION-SENSOR Country of Origin: Made in China FEATURES AND OPERATION OVERVIEW OVERVIEW • Excess gain (sensitivity) controlled by a screwdriver adjustment to prevent tampering • Fixed optics • Immune to most indirect ambient light and direct strobes • Waterproof and enclosed in high impact plastic housing • High speed (1100 μs Thru-Beam) • Potted 6’ cable • Power supply requirements: 10 to 30 VDC Note: PARTITION-SENSOR ships with a BZ-50 Power Pack SPECIFICATIONS DescriptionSpecification Supply Voltage10- 30 VDC; 5 volt models: 4.5 to 5.5 VDC, polarity protected Current RequirementsSinks up to 100mA Response TimeLight State response = 600 usµ (1,100 µs Thru-Beam) Dark State response = 600 µs (1,100 µ Thru-Beam) LED Light SourceInfrared = 880nm, Pulse-modulated LED Excessive Gain AdjustmentSensitivity controlled by a screwdriver adjustment to prevent tampering Range65’ (20m) HysteresisApproximately 20% of signal Light ImmunityHigh immunity to most ambient light Diagnostic IndicatorsRed LED = Output Status, Green LED = Power “ON” Ambient Temperature-40°F to 158°F (-40° to 70°C) Rugged ConstructionChemical resistant, high impact polycarbonate house Waterproof ratings: NEMA 4X, IP662 No: IS-00717 – Rev. B C BZ-50 Power Pack 120/277VAC, 50/60Hz, 225mA output 20A ballast or incandescent load Motor load: 1HP@120/240VAC Class 2 power supply UL 2043 Plenum Rated www.wattstopper.com • 800.879.8585 Power PackRed Red +24VDC Common Any 3-Wire 24VDC Sensor Control Output White Neut. Blue Black Re d Hot Black Switch 88T9 Appliance Control Lighting Load +24VDC CEILING WIRING LEGACY JUNCTION BOX No Connect Input +24VDC +24VDC 120/277V COMMON +24VDC Green Red Red White - No Connect Blue Red BLACK WIRE RED WIRE GREEN WIRE WHITE WIRE BLUE WIRE 1 In 1 2 In 2 3 In 3 4 In 4 5 +2 4 6 +2 4 8 +2 4 9 GN D 10 P Cel l 7 +2 4 3 4 LED 1 LED 2 Blue LEDs Config . Connect to DLM local network NOT Ethernet LED 3 LED 4 24V Overload 2 1 Control Relay Terminal A +24VDC 5, 6, 7, 8 Control Relay Terminal B INPUT 1, 2, 3, 4 PARTITION SENSOR WITH THE DLM SYSTEM LMIN-104 NOTE: Requires a SPDT (single pole double throw) +24VDC Relay supplied by others (OMRON LY2-DC24 Relay, PTF08A-E Socket) • When partition is closed, the coil on the relay will be de-energized • When partition is open, the coil on the relay will be energized • 24 VDC Coil of relay connects to Red = +24VDC Green Out of Sensor = Common NOTE 2: LMIN must be set so “Operating Mode” is Partition. In this mode, all four inputs are dedicated to Partition detection and LMIN cannot be used with any other inputs NOTE 3: Wall 1 = Input 1 • Wall 2 = Input 2 • Wall 3 = Input 3 • Wall 4 = Input 4 A B 2 SENSOR ADJUSTMENT PROCEDURES LIGHT SOURCERECEIVER Step 1: Point the light beam emitted by the light source away from the receiver Step 2: Turn the light source sensitivity adjustment fully clockwise (CW) to its maximum setting Step 3: Monitor the output LED indicator on the receiver while moving the light beam emitted from the light source in a scanning motion, first from left to right and then up and down. Use this technique to locate the mounting position that will ensure the best possible beam alignment with the receiver. Step 4: When acceptable beam alignment has been achieved, turn the sensitivity adjustment fully counter clockwise (CCW) Step 5: Turn the sensitivity adjustment clockwise (CW) 1/4 turn past the point the output LED indicator toggles to the opposite state PARTITION SENSOR WIRING DIAGRAM3 No: IS-00717 – Rev. B PARTITION SENSOR WIRING DIAGRAM BZ-50 Power Pack 120/277VAC, 50/60Hz, 225mA output 20A ballast or incandescent load Motor load: 1HP@120/240VAC Class 2 power supply UL 2043 Plenum Rated www.wattstopper.com • 800.879.8585 Power PackRed Red +24VDC Common Any 3-Wire 24VDC Sensor Control Output White Neut. Blue Blac k Re d Hot Black Switch 88T9 Appliance Control Lighting Load +24VDC CEILING WIRING LEGACY JUNCTION BOX 120/277V DOOR COMMON +24VDC Contact output RECEIVER TO: - Contact Input Station - LVOS - Keypad Station Green Red Red White - No Connect White - No Connect Blue Black BLACK WIRE RED WIRE GREEN WIRE WHITE WIRE BLUE WIRE LIGHT SOURCE Mount to flanges on each side of the sliding door or partition Align sensors on all three axis PWR OUT S E N S PWR NOTE: In Design Center, make sure it is set to normally closed (NC) polarity for the sensor OUTPUT Green IN INPUT 1, 2, 3, 4 Green, Blue Wire OUTPUT Black Ground Ground Black Wire PARTITION SENSOR WITH THE ARCHITECTURAL DIMMING SYSTEM CIS (Contact Input Station) LVOS KEYPAD When partition is closed, contact is open When partition is open, contact is closed4 800.555.9891 www.legrand.us/wattstopper No. IS-00717 – Rev. B © Copyright 2017 Legrand All Rights Reserved. © Copyright 2017 Tous droits réservés Legrand. © Copyright 2017 Legrand Todos los derechos reservados. Wattstopper warranties its products to be free of defects in materials and workmanship for a period of five (5) years. There are no obligations or liabilities on the part of Wattstopper for consequential damages arising out of, or in connection with, the use or performance of this product or other indirect damages with respect to loss of property, revenue or profit, or cost of removal, installation or reinstallation. Wattstopper garantit que ses produits sont exempts de défauts de matériaux et de fabrication pour une période de cinq (5) ans. Wattstopper ne peut être tenu responsable de tout dommage consécutif causé par ou lié à l’utilisation ou à la performance de ce produit ou tout autre dommage indirect lié à la perte de propriété, de revenus, ou de profits, ou aux coûts d’enlèvement, d’installation ou de réinstallation. Wattstopper garantiza que sus productos están libres de defectos en materiales y mano de obra por un período de cinco (5) años. No existen obligaciones ni responsabilidades por parte de Wattstopper por daños consecuentes que se deriven o estén relacionados con el uso o el rendimiento de este producto u otros daños indirectos con respecto a la pérdida de propiedad, renta o ganancias, o al costo de extracción, instalación o reinstalación. WARRANTY INFORMATIONINFORMATIONS RELATIVES À LA GARANTIEINFORMACIÓN DE LA GARANTÍA MULTI-VIEW LINE DRAWING FRONT VIEWSIDE VIEWBACK VIEW 1-3/8” 2-1/2” 2-3/8” 1” PWR S E N SNext >