Z203096-0C PAGE 1 ©2012 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com 04121Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris ‘V’ logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.TMRELAYSINSTALLATION GUIDE20A SPDT Enclosed RelayInstaller’s SpecificationsOperating Temperature -34°C to 55°C (-29° to 131°F)Operating Humidity 10-90% non condensingExpected Relay Life Electrical (at rated current): 100,000 cycles Mechanical (unpowered): 10,000,000 cyclesRelay Status LED ON=energizedWire Specifications: Lead Length 14” (356mm) min. Gauge UL1015; Coil: 18AWG; Contacts: 16AWGInsulation Class 600VAC RMSAgency Approvals UL508 enclosed device listing, pollution degree 2V220V220DIMENSIONSNOTICE• This product is not intended for life or safety applications.• Do not install this product in hazardous or classified locations.• The installer is responsible for conformance to all applicable codes.• Mount this product inside a suitable fire and electrical enclosure.INSTALLATIONDisconnect and lock out all power sources before beginning the installation.1. Using the threaded nipple, connect the relay to the desired enclosure through a knock out hole.2. Secure with the conduit nut provided.3. Connect coil wires:• Choose the coil common lead (white with yellow stripe) and connect it to the common (-) source termination point.• Choose either the low voltage (10-30VAC/DC, white with blue stripe) or high voltage (208-277VAC, white with brown stripe) lead, depending on the application requirements, and connect it to the (+) source termination point.*4. Connect relay contacts:• Choose the relay common wire (yellow) and connect to the switched load.• Choose the relay N.O. (orange) and/or* N.C. (blue) lead and connect to the switched load.5. Secure the enclosure and reconnect power.* Isolate or insulate all non-terminated wires according to local electrical code requirements, i.e. wire nut.1.6"(41 mm)1.7"(43 mm)1/2" NPT Nipple1.8"(46 mm)2.9"(74 mm)2.8"(71 mm)HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH• Follow safe electrical work practices. See NFPA 70E in the USA, or applicable local codes.• This equipment must only be installed and serviced by qualified electrical personnel.• Read, understand and follow the instructions before installing this product.• Turn off all power supplying equipment before working on or inside the equipment.• Use a properly rated voltage sensing device to confirm power is off. DO NOT DEPEND ON THIS PRODUCT FOR VOLTAGE INDICATIONFailure to follow these instructions will result in death or serious injury.DANGER Z203096-0C PAGE 2 ©2012 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com 04121Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris ‘V’ logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.TMV220INSTALLATION GUIDEWIRING EXAMPLENipple mount directly to a panelTo LoadTo ControlsCOILCONTACTSWIRING COLOR CODESCONTACT AND COIL SPECIFICATIONSNipple mount to a 4x electrical boxVoltage Coil Current AC DC24V.......................................... 75mA 32mA208V........................................ 36mA -277V........................................ 49mA -TYPICAL COIL PERFORMANCECONTACT RATINGSResistive.............. 20A@277VAC, 28VDCMotor.................... 120VAC, 1HP 277VAC, 2HPPilot Duty............. A300Ballast.................. 277VAC, 20A N.O. 277VAC, 10A N.C.Tungsten............... 120VAC, 10A N.O. 120VAC, 2A N.C.To ControlsPOWERSOURCEFractionalHP MotorN.C.Common24VAC/DCLOWwht/blueCOMMwht/yellowCommonN.O.CONTACT OUTPUTCONTROL SYSTEM INPUTWhiteYELLOWWhiteORANGEblue blue yellow yellow 208-277VACHIwht/brownWhitebrown brown Next >