MODELDESCRIPTION SD Spot Detector • Operates on either 12 to 36 Vac or 18 to 36 Vdc power • Includes a 14 ft. (4.2 m) leader cable SD-R01 Spot Detector with Relay Output • Works with any system that accepts dry contacts • Operates on 24 Vac/dc ±10% • Automatically resets when conductive fluid is no longer present (AC power only; if DC power is used, device must be reset by disconnecting power momentarily) • Includes a 14 ft (4.2 m) leader cable SD-Z Spot Detector • Designed for use with all RLE detection panels, with SC sensing cable to integrate both zone and spot detection into one panel • Powered by the LD310, LD1000, LD5200, LDRA6, or LD2000 • When used with a distance read panel (LD2000 or LD5200), the location of the leak will be identified (simulates 50 feet) • Includes one male and one female end connector, each on a 1 ft (30 cm) lead wire MX1 Spot Detector • Battery operated Input Power: SD-R01 Only24 Vac/dc ±10%; 0.1 A max. (AC: 50/60 Hz) Storage Environment-20 to 70 °C (-4 to158 °F) OUTPUTS Solid-state: SD Only 12 to 36 Vac@0.01 A min., 0.1 A max., 50/60 Hz; 18 to 36 Vdc@0.01 A min., 0.1 A max. Relay: SD-R01 Only Dry Contact, Form C; 1 A@24 Vdc, 0.5 A @120 Vac resistive LEADER CABLE (NSC) Length: SD SD-R01 SD-Z 14 ft. (4.2 m) 14 ft. (4.2 m) 10 ft. (0.3 m) (2 cables included) Connector: SD-Z Only 1 male, 1 female; 4 pin, 0.96” (24.38 mm) diameter; connects to SC or NSC Cable OPERATING ENVIRONMENT Temperature0 to 50 °C (32 to 122 °F) Humidity5% to 95% RH non-condensing Altitude10,000 ft. (3,048 m) max. WARRANTY Limited Warranty2 years Input PowerTypical 10-year life lithium battery OutputN.C. solid-state, (opens on alarm) Output Rating30 Vac/dc@0.1 A max., not polarity sensitive Sensing ElectrodesGold plated OPERATING ENVIRONMENT Temperature-20 to 80 °C (-4 to 176 °F) Humidity0 to 100% RH Water ResistanceNot for continuous submersion WARRANTY Limited Warranty5 years AGENCY APPROVALS SD, SD-R01, SD-Z and MX1 Spot Detectors detect conductive fluids at a single point for the most economical way to detect fluids in small, confined areas. These devices are commonly used in small rooms and in air-conditioning drip pans. Use only with SC conductive fluid leak detection cables. Veris offers four models of spot detectors which can integrate with various building management systems. SD SD-Z MX1 SPECIFICATIONS SD, SD-R01, SD-Z SPECIFICATIONS MX1 I N TE RT E K CUS L I STE D CM LISTED 3037024 Simple installation Simple installation – screw, or ram- set to floor (SD, SD-R01, SD-Z) Polymer coated SD, SD-R01, SD-Z models have polymer-coated sensing probes... no exposed metal that will rust Simple operation Simple operation…no maintenance Durability All models are fully potted for water resistance…maximum durability Solid-state design No moving parts to fail 800.354.8556 | +1 503.598.4564 | sales@veris.com | intl@veris.com | www.veris.com SD, SD-R01, SD-Z & MX1 Spot Leak Detectors Leak Detection | Spot Leak Detectors HQ0001797.H 0720or SC NSC End Terminator (EOL) Leader cable kit (LC-Kit) Spot detector (SD-Z) LD1000 LD310 24 Vdc (not polarity sensitive) (Normally Closed) Reset Push Button White/Red (+) Black (-) Once triggered, device remains on until power is removed (if using Vdc power). 24 Vac/dc (Normally Closed, Vdc applications only) Reset Push Button Red (+) Brown (Not Used) Blue (N.C.) Green (Comm) White (N.O.) Black (-) Once triggered, device remains on until power is removed (if using Vdc power). 1.0” (25 mm) 0.3” (8 mm) = 0.2” (5 mm) 2.1” (52 mm) 2.9” (73 mm) 0.3" (7 mm) 0.3" (7 mm) 0.6" (14 mm) 0.75" (19 mm) 1.75" (44 mm) 1.2" (30 mm) 0.5" (13 mm) MODELMANUF. PART #DESCRIPTIONCEETL U006-0006SDSpot Detector, 14’ leader cable•• U006-0007SD-R01Spot Detector, 14’ leader cable, relay out•• U006-0008SD-Z*Spot Detector, 2x10” leader cable•• MX1BMX1BSpot Detector, battery * The SD-Z uses DIN style connectors. Connect it via the LC-KIT, or integrate it into an LC-KIT-SC/NSC cable configuration. SD Wiring Diagram SD-R01 Wiring Diagram SD-Z Wiring Diagram MX1 SERIES Wiring Diagram SD SERIES Dimensional Drawing MX1 SERIES Dimensional Drawing ORDERING INFORMATION 800.354.8556 | +1 503.598.4564 | sales@veris.com | intl@veris.com | www.veris.com Leak Detection | SD, SD-R01, SD-Z & MX1 HQ0001797.H 0720 DIGITAL CONTROL Digital Input White GreenNext >