Sensor Power30 mA (max) @ 12 to 30 Vdc Insulation Class600 Vac RMS (UL), 300 Vac RMS (CE 1 ) Frequency Range50/60 Hz Temperature Range-15 to 60 °C (5 to 140 °F) Humidity Range10 to 90% RH, non-condensing Accuracy±2% from 10 to 100% of full scale Response Time2 sec. Terminal Block Wire Size12 AWG (3.3 mm 2 ) - 22 AWG (0.33 mm 2 ) Terminal Block Torque7 to 8 in-lbs (0.8 to 0.9 N-m) WARRANTY Limited Warranty5 years AGENCY APPROVALS Agency Approvals UL 508 open device listing, CE: EN61010-1, (H221, H321 only)CAT III, Pollution Degree 2, basic insulation SENSED AMPS 100 to 300A (H221/H221SP) 300 to 800A (H321/H321SP) 1000 to 2400A (H421/H421SP) 0A* 4mA 20mA SENSOR OUTPUT *Adjusted with Span Potentiometer for Hx21 models; Factory-set per customer specification for Hx21SP models H321 1. The CE mark indicates RoHS2 compliance. Please refer to the CE Declaration of Conformity for additional details. TM Maximize Reliability Minimize Installed Cost EXAMPLE LINEAR OUTPUT Scale software as shown APPLICATIONS • Load trending of large motors and other loads up to 2400 A • Monitor critical motors (compressor, fuel, etc.) Hawkeye x21/x21SP analog current transducers provide reliable load trending information for large motor loads (up to 2400 A), with a proportional 4 to 20 mA signal. Three devices are available, each with a different amperage range. The Hx21 versions include a span potentiometer that allows each sensor to be calibrated for maximum resolution. The Hx21SP versions are factory-calibrated at a range specified by the customer. SPECIFICATIONS Split-core design Split-core design for easy installation and fast retrofits Loop powered Loop powered 4 to 20 mA output No need for external CTs No need for external CTs on large conductors Two-wire design Two-wire design reduces wiring cost Large openings Large openings for heavy conductors Field flexibility Hx21 models offer zero and span adjustments for field flexibility 800.354.8556 | +1 503.598.4564 | sales@veris.com | intl@veris.com | www.veris.com TM Current Monitoring | Current Transducers: 4 to 20 mA Analog Output, High Current Monitoring HX21 & HX21SP SERIES Large Load Trending with 4 to 20 mA Output HQ0001763.F 0117MODELAMPERAGE RANGE SENSOR OUTPUT HOUSINGULCE LEAD FREE 4 mA (Lower Limit) 20 mA (Upper Limit) H221 0 A 100 to 300 A 4 to 20 mA DC Split-core • 1 • H221SP100, 150, 200, 250, or 300 A 2• 1 • H321300 to 800 A • 1• H321SP300, 400, 500, 600, 700, or 800 A 2 • 1 • H4211000 to 2400 A• H421SP 1000, 1200, 1400, 1600, 1800, 2000, 2200, or 2400 A 2 • 1. Listed for use on 75 °C insulated conductors. 2. Factory calibrated - not field adjustable. Note: When ordering HxxxSP versions, specify upper current limit for factory calibration (device is not field adjustable). ORDERING INFORMATION DIMENSIONAL DRAWINGMONITORING FAN /PUMP MOTORS LOADS Wiring Diagram Voltage Output Current Monitoring | Hx21 & Hx21SP Series HQ0001763.F 0117Next >