SPECIFICATIONS Sensor PowerN.O models: Induced from monitored current; H800NC: 5 to 30 Vdc, permanently connected Insulation Class600 Vac RMS (UL), 300 Vac RMS (CE*) Frequency Range50/60 Hz, On/Off status for Variable Frequency Drive (VFD) outputs at 12 to 115 Hz (a) Temperature Range: H800NC, H300, H900 H600 H800, H800HV -15 to 60 °C (5 to 140 °F) -15 to 40 °C (5 to 104 °F) (to 200 A); -15 to 60 °C (5 to 140 °F) (to 150 A) -40 to 50 °C (-40 to 122 °F) (to 200 A); -40 to 75 °C (-40 to 167 °F) (to 100 A, and 0.25 A status output) Humidity Range10 to 90% RH non-condensing Off State Leakage (H800NC Only) 34 μA @ 5 Vdc, 200 μA @ 30 Vdc On State Voltage Drop (H800NC Only) 1.9 Vdc (max.) @ 0.1 A Maximize Reliability Minimize Installed Cost HX00 SERIES On/Off Status Current Switches APPLICATIONS Hawkeye x00 on/off current switches provide a cost-effective solution for monitoring status on unit vents, exhaust fans, recirculation pumps, and other fixed loads where belt loss is not a concern. Veris has applied new technology to the H300, H600, and H800 models to achieve impressive improvement in turn-on levels. The Hawkeye H300 and H600 have the lowest turn-on current in the industry at a mere 0.15 A! H800 H300 H900 H600 Terminal Block Wire Size H600, H800, H900 H300 24 to 14 AWG (0.2 to 2.1 mm 2 ); 22 to 16 AWG (0.3 to 1.3 mm 2 ) Terminal Block Torque H600, H800, H900 H300 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m); 7 in-lbs (0.8 N-m) WARRANTY Limited Warranty5 years AGENCY APPROVALS Agency approvalsUL 508 open device listing; CE: EN61010-1, CAT III, Pollution Degree 2, basic insulation *The CE mark indicates RoHS2 compliance. Please refer to the CE Declaration of Conformity for additional details. Note: Do not use the LED status indicators as evidence of applied voltage. (a) VFD systems generate fields that can disrupt electrical devices. Ensure that these fields are minimized and are not affecting the sensor. • Electrical load status • Direct-drive units, exhaust fans, process motors, and other fixed loads • Lighting run times and status • VFD output On/Off status • Direct-Drive units, unit vents, fan coil units, exhaust fans, and other fixed loads E150462 Reliable More reliable for status than relays across auxiliary contacts Installation flexibility Removable mounting bracket provides installation flexibility Ideal for direct- drive units Ideal for direct-drive units, unit vents, fan coil units, exhaust fans, and other fixed loads Flexibility Bracket on H900 can be installed in three different configurations Low setpoint Minimum trip point as low as 0.5 A (H608)…avoids the need for multiple wraps of the conductor through the sensor even on loads as small as 1/5 HP Quick installation Split-core H300, H600 and H900 for fast retrofit installation 800.354.8556 | +1 503.598.4564 | sales@veris.com | intl@veris.com | www.veris.com TM Current Monitoring | Current Switches: Fixed Trip Point HQ0001753.F 0117MODEL AMPERAGE RANGE @ 50/60 HZ ONLY STATUS OUTPUT (MAX.) TRIP POINT HOUSINGULCE LEAD FREE H300 0.15 to 60 AN.O. 1.0 A @ 30 Vac/dc0.15 A or lessSplit-core• 2 • H600 0.15 to 200 AN.O. 1.0 A @ 30 Vac/dc0.15 A or lessSplit-core• 1 • H800 0.25 to 200 AN.O. 1.0 A @ 30 Vac/dc0.25 A or lessSolid-core• 1 • H800NC 0.5 to 200 AN.C. 0.1 A @ 30 Vdc0.5 A or lessSolid-core • 1 • H800HV 0.75 to 200 AN.O. 0.5 A @ 250 Vac/dc0.75 A or lessSolid-core • 3 H900 1.5 to 200 AN.O. 1.0 A @ 30 Vac/dc1.5 A or lessSplit-core•• POWER SOURCE BUILDING AUTOMATION CONTROLLER UNIT VENT HEATER Digital Input Digital Input 2.5" * (64 mm) 2.1" (54 mm) 3.5" (89 mm) 2.9" (74 mm) 0.4” x 0.2” (10 mm x 5 mm) Slot (2x) 1.2" (31 mm) Removable Mounting Bracket 0.7" (18 mm) 0.5" (13 mm) 2.1" (54 mm) 1.0" (26 mm) 0.6" (16 mm) Self-gripping Iris 0.7" (18 mm) 0.4” x 0.2” Slot (x2) 2.8" * (71 mm) 1.7 (43 mm) 2.3" (58 mm) 1.1" * (27 mm) 0.9" (23 mm) Removable/Adjustable Mounting Bracket Removable Mounting Bracket 0.3” (8 mm) 6 AWG max. 1.6” (40 mm) 1.5” (38 mm) 0.6” (15 mm) 1.8” (46 mm) Ø 0.18” (x2) (5 mm) Self-gripping Iris Removable Mounting Bracket Self-gripping Iris 1.0” (25 mm) 0.8” (21 mm) 1.1” (26 mm) 3.1”** (79 mm) 2.8” (70 mm) Ø 0.3” (8 mm) 1.4”* (36 mm) 2.5” (64 mm) 3.0” (76 mm) Bracket can be mounted on three sides for added installation flexibility. ORDERING INFORMATION H300 Dimensional Drawing H800, H800HV, H800NC Dimensional Drawing H600 Dimensional Drawing H900 Dimensional Drawing UNIT VENT HEATER CONTROL Wiring Diagram * Terminal block may extend up to 1/8” over the height dimensions shown.* Terminal block may extend up to 1/8” over the height dimensions shown. ** Slide switch may extend up to 1/4” over the height dimensions shown. 1. Listed for use on 75°C insulated conductors. 2. Product provides functional insulation only. 3. Listed for use on 90°C insulated conductors. 800.354.8556 | +1 503.598.4564 | sales@veris.com | intl@veris.com | www.veris.com TM Current Monitoring | Hx00 Series HQ0001753.F 0117Next >