6 | 866-660-8864 | fax 503-296-2529 | www.senvainc.comPatent PendingNext time, I’m using Senva. OSHA requires protection when working in energized enclosures; just use Senva never calibrate live again!Thanks to PRESET™ you’ll never calibrate in live enclosures again! Reduce the risk of arc flash with Senva.Save over 1/2 hour per sensor install.No guesswork. Multi-turn adjustments are a thing of the past.If you’re calibrating current sensors in energized enclosures, you’re wasting time and money. Worse, you should be suiting up for arc flash protection (yes, it’s OSHA code). If you’re not, you’re exposed to injury and liability. Senva makes it safe, simple, and profitable.The safest, most cost-effective proof of flow for fans and pumps is with Senva Sensors. Set the sensor to motor full load amps—never return to calibrate!PreSet™ sensors let you set the dial to the motor amperage. You can install the sensor and never return back to calibrate. Installers tell us they save over ½ hour per sensor. Plus, they’re safe. You do the math.Never calibrate live again!Split Core Mini now available!8 | 866-660-8864 | fax 503-296-2529 | www.senvainc.comProudlyMade in the U.S.A.Scaled calibration for proof of flow set-pointSplit and solid core models to 150AN.O. 30VAC/DC or 120VAC output Optional command relay DESCRIPTION PreSet™ allows for matching sensor set-point to the motor nameplate, eliminating the need to calibrate in energized enclosures and reducing installation time. Sensor will detect motor undercurrent conditions such as belt loss, coupling shear, and mechanical failure on fans and pumps. APPLICATIONS ▪Detecting belt loss, coupling shear, and mechanical failure on fans and pumps ▪Monitoring status of industrial processes ▪Monitoring status of critical motorsFEATURESOffFan/pump OnElectrical FailureLoss of Belt/Coupling ShearOffCalibrated Trip PointSET-POINT OPERATIONDetects Belt Loss/Coupling Shear!Now you can easily detect when drive belts slip, break, or pump coupling shear. In fact, a typical HVAC motor that loses its load has a reduction of current draw of up to 50%. That’s why our sensors are the industry standard for status.Save time and money while eliminating calibration inside energized enclosures ▪Preset™ scaled calibration enables set-point adjustment for proof of flow by simply matching dial to motor full load amps (FLA) nameplate ▪Safer: Eliminates calibration in energized enclosures, reduces arc flash hazard ▪No need to return to calibrate—saves time and money ▪Super low turn-onMaintenance-free—no call backs ▪Superior to traditional adjustable CTs and pressure switches ▪Industry leading 7 year warrantySimply set to motor FLA for proof of flow set-pointReduce the risk of arc flash because sensor is calibrated to motor FLA nameplateSave over 1/2 hour per sensor install—based on field productivity tests.No hazardous guesswork. Multi-turn adjustments are a thing of the past.CURRENT PreSet™ SeriesPatent PendingPatent PendingPreSet™ Adjustable Current SwitchHigher Reliability, Faster Installation, Superior Accuracy | Sense the difference | 9 V+DICONTROLLER(SINKING)(SOURCING)(AC)INSULATED PRIMARYAC CONDUCTOR600VAC MAXV+DI24VACDIV+DIALTERNATECONTROLLER ARRANGEMENTSDIDIVACGNDNOTE: Device is NOT polarity sensitive.vStatus Output1.0A @ 30VAC/DCNormally OpenOutput closed above 70% of FLA11008570605040302010HILOSet knobto motorFLAIn the U.S.ADesigned and Assembled7 year limited warrantyCURRENT PreSet™ SeriesORDERING INFORMATIONSPLIT COREMin (on)Max AN.O. Output*Trip LEDPower LEDC-2320-L0.45A50A1.0A@30VAC/DC••C-2320 0.50A100A1.0A@30VAC/DC••C-2320-H 0.50A150A1.0A@30VAC/DC••C-2320HV 0.50A100A0.2A@120VAC••C-2320HV-L0.45A50A0.2A@120VAC••SPLIT CORE - MINIC-22201.00A 50A1.0A@30VAC/DC•SOLID CORE C-13200.75A50A1.0A@30VAC/DC•SOLID CORE - MINIC-1220-L0.75A5A1.0A@30VAC/DC•C-12200.75A50A1.0A@30VAC/DC•C-1220HV-L0.75A5A0.2A@120VAC•C-1220HV 0.75A 50A 0.2A@120VAC•Other coil voltages available—consult factoryCOMMAND RELAYContact ratingCoilCR3-24N.O. 10A @ 125VAC24VAC/DC 15mA nom.CR4-24N.C. 10A @ 125VAC24VAC/DC 15mA nom.CR3-12N.O. 10A @ 125VAC9-12VDC 30mA nom.CR4-12N.C. 10A @ 125VAC9-12VDC 30mA nom.SPECIFICATIONSStandard Output Rating1.0A@30VAC/DCLine Voltage Output Rating0.2A@120VAC (-HV ONLY)Output TypeNO, solid-state FETTemperature Rating-15-60 ° CInsulation Class600V RMS. For use on insulated conductors only! Use minimum 75 ° C insulated conductorSensor PowerInducedFrequency Range50/60HzTYPICAL WIRINGWarning: Refer to installation instructions that accompany product and heed all safety instructions. Do not rely on current status LED to indicate presence of power.Ordering tip: For best resolution, choose the sensor lowest maximum amperage which accomodates your motor (e.g. 0-50A us -L, 50-100A use standard, 100 to 150A use -HHSPLIT COREC-2320 OPTIONAL RELAYfor additional labor savingsSOLID COREC-1320 SPLIT CORE - MINIC-2220 SOLID CORE - MINIC-1220 L: 2.5” H: 0.57” W: 2.23” A: 0.75"x 0.75" ▪Mount sensor without removing conductor for installation savings ▪Clamp on conductor with iris, or use detach-able base to screw or DIN mount ▪Larger 0.75” aperture accomodates oversize conductors ▪Add to 2320 series to get start/stop/status in a single device ▪Reduces the number of installed components... saves time and space ▪Removable relay facilitates service ▪Mount sensor without removing conductor for installation savings ▪Fits in small enclosures ▪Clamp on conductor with iris, or screw mount detachable base ▪Super small—fits anywhere ▪Low costL: 1.91" H: .88" W: 1.31" A: 0.30” diameterL: 2.40" H: 1.04" W: 1.6" A: 0.52” diameterL: .84" H: .72” W: 2.06" ▪Compact design ▪Aperture accomodates spade terminalsLWAperture (A)Aperture (A)L: 2.00” H: .75” W: 1.75” A: .0.40”x 0.32”NEW LOWER TURN-ON!Next >