16 | 866-660-8864 | fax 503-296-2529 | www.senvainc.comLoadAmpsFactory calibrated0ASensor Output4mA0 VDC20mA5/10 VDC30/60/120A7 year limited warrantyIn the U.S.ADesigned and AssembledAnalogCurrent Sensors0-5VDC, 0-10VDC, 4-20mA outputs Multiple selectable range split-cores Optional command relayFixed ranges on solid-coresDESCRIPTION Senva analog transducers measure AC current and provide a proportional output for load trending and control. Choose from easy to install split-core or compact solid core. Selectable ranges and optional command relay make for a versatile transducer.APPLICATIONS ▪Load trending ▪Motor control ▪Process control ▪Fan/Pump status ▪Motor load jamming ▪Lighting load levelsSplit-core switch selectable ranges (30, 60, 120A or 5, 10, 20A full scale ranges) ▪Makes scaling easy ▪Reduces inventory ▪No call backs due to mis-sizing0-5VDC, 0-10VDC, 4-20mA loop powered versions ▪Versions compatible with any systemSuperior split core design for easy installation ▪Mount sensor without removing conductor for installation savings ▪Clamp on conductor with iris or use detachable base to screw or DIN mount ▪Larger 0.75” aperture accomodates oversize conductorsSnap-on command relay for unitary start/ stop/status ▪Reduces the number of installed components… saves time and space ▪Removable relay facilitates serviceReliable and cost-effective ▪Industry leading 7 year limited warrantyFEATURESSPECIFICATIONSTemperature Rating-15-60 ° CInsulation Class600V RMS. For use on insulated conductors only! Use minimum 75 ° C insulated conductorFrequency Range50/60HzSET-POINT OPERATION- MODELS C-2343, C-2344, C-2345CURRENT Analog SeriesHigher Reliability, Faster Installation, Superior Accuracy | Sense the difference | 17 CONTROLLERINSULATED PRIMARYAC CONDUCTOR600VAC MAXAIAIGNDNOTE: Device IS polarity sensitive.vScaling:0-15A0-5VDCOutput-+V+VdcCONTROLLERINSULATED PRIMARYAC CONDUCTOR600VAC MAXV+AINOTE: Device IS polarity sensitive.vScaling:0-15A4-20mA12-30VDCLoop-+#! Rplace image? Warning: Refer to installation instructions that accompany product and heed all safety instructions. TYPICAL WIRING LOOP 4-20 MATYPICAL WIRING 0-5/10VDC OUTPUTSPLIT COREC-234XOPTIONAL RELAYSOLID COREC-120XL: 2.5” H: 0.57” W: 2.23” A: 0.75”x. 0.75” ▪Mount sensor without removing conductor for installation savings ▪Clamp on conductor with iris, or use detach-able base toscrew or DIN mount ▪Larger 0.75” apeture accomodates oversize conductorsL: 0.84” H: .72” W: 2.06” ▪Add to 234X series to get start/stop/status in a single device ▪Reduces the number of installed components... saves time and space ▪Removable relay facili-tates serviceL: 1.78” H: .88” W: 1.31” A: 0.30” diameter ▪Compact design ▪Apeture accomodates spade terminalsCURRENT Analog SeriesORDERING INFORMATIONSPLIT CORERange AOutputSensor PowerC-234330A, 60A, 120A Selectable0 - 5 VDCInducedC-2344 30A, 60A, 120A Selectable0 - 10 VDCInducedC-234530A, 60A, 120A Selectable4 - 20mALoop- powered, 30 VDCC-2343-L5A, 10A, 20A Selectable0 - 5 VDCInducedC-2345-L5A, 10A, 20A Selectable4 - 20mALoop- powered, 30 VDCC-2343-200200A0 - 5 VDCInducedC-2344-200200A0-10 VDCInducedSOLID CORE - MINIC-120315 A0 - 5 VDCInducedC-120515 A4 - 20mALoop- powered, 30 VDCC-1203-L5 A0 - 5 VDCInducedLHWAperture (A)Aperture (A)COMMAND RELAYContact ratingCoilCR3-24N.O. 10A @ 125VAC24VAC/DC 15mA nom.CR4-24N.C. 10A @ 125VAC24VAC/DC 15mA nom.CR3-12N.O. 10A @ 125VAC9-12VDC 30mA nom.CR4-12N.C. 10A @ 125VAC9-12VDC 30mA nom.Next >