1 | 866-660-8864 | fax 503-296-2529 | www.senvainc.com Indoor Environmental and Air Quality Sensor Matrix Industry’s first IAQ sensor with PIR motion detection Eight environmental sensors: PIR, PMx, VOC, CO2, RH, T, ambient light, barometric pressure BACnet/Modbus or analog outputs with set-point relay APPLICATIONS ▪ Verify effectiveness of IAQ strategies in post covid environment ▪ Energy management/building control ▪ Facilitates compliance with ASHRAE 62.1 standard for air quality ▪ Contributes toward satisfying Feature A08 and T06 under the WELL Building Standard® DESCRIPTION The TotalSense TM Series provides more data for more advanced ventilation control while drastically reducing installation cost and time on a project. It includes a comprehensive selection of IAQ sensing with carbon dioxide (CO2), relative humidity (RH), and temperature plus options for occupancy detection (PIR), total volatile organic compounds (TVOC), particulate matter (PM) and ambient light. More than an IAQ sensor, it’s the first fully configurable Indoor Environmental Quality (IEQ) sensor matrix. Motion detection (PIR) can initiate ventilation upon occupancy, providing air exchanges the instant people are present (in addition to monitored elevated CO2 levels). This technology provides a much faster trigger for ventilation allowing for cleaner and safer indoor spaces while still saving energy. PIR and ambient light sensors can also be utilized for light harvesting for additional energy savings and code compliance. NEW ! FEATURES ▪ Reduce installation costs with multiple sensors in a standard size enclosure ▪ Specify the exact product with over 25,000 unique combinations ▪ Color display and Air Quality Ring for tenant assurance (programmable) ▪ Initiate ventilation immediately upon occupancy detection for healthier buildings and energy savings ▪ Sense unhealthy or offensive air with TVOC. Compensated for temperature and barometric pressure for total accuracy ▪ Detect a variety of PM sizes to indicate airborne respiratory droplets, allergens, and other dangers ▪ Industry-leading temperature and barometric pressure compensated CO2 sensing with non-dispersive infrared sensing element (NDIR), 15+ year life expectancy on CO 2 sensing element; ±30ppm, ±3% of reading ▪ Capacitive touch buttons make setup and use simple ▪ Slim and sleek surface-mount enclosure is tamper-proof and easy to install ▪ Field-replaceable PM, RH, Temp, and CO 2 sensors ease maintenance ▪ Set-point sliders and pushbuttons are also available to meet the requirements for any job ▪ 7-year limited warranty / 3 years on CO 2 sensor - 2 years on all others Slim surface-mount enclosure Made in USA Versatile display (optional) T talSense TM SeriesHigher Reliability, Faster Installation, Superior Accuracy | Sense the difference | 2 AIR QUALITY EIGHT TECHNOLOGIES FOR OPTIMUM INDOOR AIR QUALITY PIR (Passive Infrared) Motion detector typically used for lighting control that can also be used to immediately indicate occupancy and deliver fresh air CO 2 (Carbon Dioxide) Detect levels of CO 2 indicating occupancy to trigger ventilation (field replaceable) PM x (Particulate Matter) Detect the presence of airborne bacteria, dust, pollen, and other airborne particulates. Can be used to determine the effectiveness of filtration (field replaceable) Ambient Light Adjust lighting levels based on natural light for energy savings TVOC (Total Volatile Organic Compounds) Monitor for toxins from chemical by-products of manufacturing, paints, cleaning products, solvents, and more Temperature Maintain comfort levels (field replaceable) RH (Relative Humidity) Monitor humidity - regulating humidity levels ensures occupant comfort and may minimize risk of spreading pathogens (field replaceable) Barometric Pressure Used to compensate TVOC and CO2 readings OPTIONS Versatile Display ▪ Fully customizable ▪ Good/Fair/Poor settings and color icons available Non-Display for more discreet sensing ▪ Display + cover option also available for ease of setup PIR Motion Sensing ▪ Trigger ventilation or lighting based on occupant movement TVOC and PM Sensors ▪ Detect unhealthy airborne particulates or VOC’s for a comprehensive understanding of indoor air quality. Analog outputs or BACnet MSTP / Modbus RTU ▪ Compreshensive data ▪ Intregrated set-point relay (programmable) Air Quality Ring ▪ Provides occupants assurance without confusing metrics ▪ Green/yellow/red3 | 866-660-8864 | fax 503-296-2529 | www.senvainc.com SPECIFICATIONS Power Supply Non-Display16-30VDC/24VAC (1) , 3.5W nominal, 4W max. Display or LED Ring24-30VDC/24VAC (1) , 4.3W nominal, 5W max. Interface OLED (optional)1.5” Organic LED Display, 128x128, color Air Quality RingColor changing (red/yellow/green) LED Air Quality Ring Analog Outputs (Analog version only) QuantityUp to 3 outputs SourceCO2, RH%, Temp, Temp slider, TVOC (selectable) Scale0-5V, 0-10V, 4-20mA (switch selectable, programmable per output) Protocol Output (Comms version only) ProtocolBACnet MS/TP or Modbus RTU Connection3-wire RS-485, with isolated ground Data Rate9600, 19200, 38400, 57600, 76800, 115200 (switch selectable) Address Range0-127 Relay (Standard except for PM models) TypeSolid-state output, 1A @ 30VAC/DC, N.O. PolarityNO/NC (selectable) Source CO2 setpoint, RH setpoint, Temp setpoint, TVOC setpoint, PIR motion detection, Air Quality, off (selectable) CO2 (Optional) TypeNon-dispersive Infrared (NDIR) Accuracy ±(30ppm + 3% of reading) (400-2,000ppm), -10-50ºC, 0-85%RH ±(50ppm+ 5% of reading) (2,000-5,000ppm), -10-50ºC, 0-85%RH >5,000ppm consult factory Resolution1 ppm Range0-2,000 PPM (Default) (Programmable up to 10,000ppm) Response time 90 seconds to 90% reading Sample rate1s Temp and Pressure CompensationYes, barometric pressure readable over comms Relative Humidity (Optional) TypeDigital CMOS Accuracy(2)2% models, +/-2% over 0 to 80%RH range Resolution0.05%RH Response time (3) 30s Sample rate3s Operating range0 to 100%RH (non-condensing) Operating conditions (4) -4 to 140oF (-20 to 60° C) @ RH>90%; -4 to 176oF @ RH=50% Temperature Transmitter (Optional) With RH optionWithout RH option TypeSilicon Band-gapNTC Thermistor Nominal Accuracy±0.3° C (operating range)±0.5° C (operating range) Maximum Accuracy (2)±0.5° C (at 25° C), ±1.0° C±1.0° C (at 25° C), ±2.0° C Resolution0.1° C0.05° C Response time30s30s Sample rate3s100 milliseconds TVOC (Optional) TypeMOS GasTotal VOC Range0-10,000 μg/m3 (Display may be programmed to show PPB) Response Time<10s Temp and Pressure CompensationYes Output0-2,000 μg/m3 (default) programmable up to 10,000 μg/m3 1. One side of transformer, secondary is connected to signal common. Dedicated transformer is recommended. 2. Models with PM sensor included achieve ±5% accuracy over 0 to 80%RH range and an additional temperature shift of up to +0.5ºC 3. Time for reaching 63% of reading at 25° C and 1 m/s airflow 4. Long term exposures to conditions outside normal range at high humidity may temporarily offset the RH reading (+3%RH after 60 hours.)Higher Reliability, Faster Installation, Superior Accuracy | Sense the difference | 4 AIR QUALITY ORDERING AQ2 - Package W = Surface Output Type A = Analog B = BACnet/ Modbus Temperature Output A = None B = Transmitter C = 100Pt RTD D = 1000Pt RTD E = 10K Type 2 F = 10K Type 3 G = 10k w/11k H = 3k I = 2k2 J = 1k8 K = 20k CO2 A = None C = CO2 D = Dual Channel CO2 Relative Humidity A = None 2 = 2% RH VOC A = None V = VOC Particulate Matter* A = None P = PM 1.0, 2.5, 4.0, 10.0 Display X = None D = OLED Display S = OLED display with solid cover R = Air Quality Ring *PM Available on AQ2W-B Surface mount + BACnet/Modbus versions only **Additional SP sliders and offset resistors available upon request **Slider and pushbutton options not available with PM sensor. Call for additional slider and override options. Accessories** C = 1k Ω SP Slider F = 10k Ω SP Slider E = 910 Ω offset resistor S= Slider override PB O = Thermistor Override PB U = User PB PIR Sensor P = PIR Sensing SPECIFICATIONS PMx (Optional) CLASS 1 LASER PRODUCT TypeOptical Size RangePM1.0, PM2.5, PM4.0, PM10.0 Scale0-1,000 μg/m3 Lower detection limit0.3 μm Precision±10 μg/m3 (0-100μg/m3); ±10% (100-1,000 μg/m3) Long-Term Drift±1.25 μg/m3 / year PIR (Optional) TypePassive Infrared Axis X field of view140o, 15 ft (4.5m) Axis Y field of view76o, 15 ft (4.5m) Ambient Light TypePhototransistor Scale0-100 fc (lm/ft2), readable over comms Operating Environment Temperature32 to 122oF (0 to 50oC) Humidity0-95% non-condensing Enclosure MaterialABS Plastic Dimensions5.67”h x 3.00”w x 1.07”d (With concealing ring: 6.35”h x 3.69”w x 1.25”d) ComplianceAgencyCE, RoHS Concealing Ring (Provided) ▪Conceal oversized drywall cutouts or European junction boxes Standard Surface Mount DIMENSIONS BACnet® is a registered trademark of ASHRAE 1.25 [31.6] .229 [5.8] 6.35 [161.3] 3.69 [93.7] 1.07 [27.1] 3.0 [76.2] 5.66 [143.8]Next >