TotalSenseSeries OutdoorAirQualitySensor Buildacompleteairqualitysystemforindoor,duct,andoutdoor Six environmentalsensors:PMx,VOC,CO2,RH,T,barometricpressure BACnet/Modbusoranalogoutputswithset-pointrelay DESCRIPTION TheTotalSenseSeriesOutdoorAQsensorprovidesmoredataformore advancedventilationcontrolwhiledrasticallyreducinginstallationcostandtime onaproject.ItincludesacomprehensiveselectionofAQsensingwithcarbon dioxide(CO2),relativehumidity(RH),andtemperatureplusoptionsfortotal volatileorganiccompounds(TVOC),barometricpressureandparticulatematter (PM).Thissensorisenclosedinanoutdoorratedenclosuretoprotectelectronics fromrain,overheadwateringsystemsandharmfulUVrays. APPLICATIONS Measureoutdoorairqualityforindoor/outdoor comparisontomeet ASHRAE62.1standardfor airquality • VerifyeffectivenessofIAQstrategiesinpost covidenvironment • Energymanagement/buildingcontrol• ContributestowardsatisfyingFeatureA08and T06undertheWELLBuildingStandard® • FullyconfigurabledisplayChooseupto6airqualityindicatorsBuildafullvalidationsystem BACnet/Modbusprotocolsorupto3analog outputs MadeinUSA;7yearwarrantyonelectronics HigherReliability,FasterInstallation,SuperiorAccuracy|SensetheDifference 866-660-8864|fax503-296-2529|www.senvainc.com 1FEATURES Reduceinstallationcostswithmultiplesensorsin arugged, easy-mount outdoorenclosure • SpecifytheexactproductforyourapplicationwithmadeinUSA• Senseunhealthy particulatesorTVOC'sbeforedeliveringit indoors • Industry-leadingtemperatureandbarometricpressure compensatedCO2sensingwithnon-dispersiveinfraredsensing element(NDIR),15+yearlifeexpectancyonCO2sensing element;±30ppm,±3%ofreading • Tamper-proof• Field-replaceableRH,Temp,andCO2sensorseasemaintenance• 7-yearlimitedwarranty/3yearsonCO2sensor-2yearsonall others • ORDERING HigherReliability,FasterInstallation,SuperiorAccuracy|SensetheDifference 866-660-8864|fax503-296-2529|www.senvainc.com 2DIMENSIONS SPECIFICATIONS PowerSupplyWithoutDisplay WithDisplay 16-30VDC/24VAC(1),3.5Wnominal,4Wmax. 24-30VDC/24VAC(1),4.3Wnominal,5Wmax AnalogOutputs(Analogversiononly)QuantityUpto3outputs SourceCO2,RH%,Temp,PM,TVOC(selectable) Scale0-5V,0-10V,4-20mA(switchselectable,programmableperoutput) ProtocolOutput(Communicationsversiononly)ProtocolBACnetMS/TPorModbusRTU Connection3-wireRS-485,withisolatedground DataRate9600,19200,38400,57600,76800,115200(switchselectable) AddressRange0-127 RelaySet-point(standardexceptforPMmodels)TypeSolid-stateoutput,1A@30VAC/DC,N.O. SourceCO2setpoint,RHsetpoint,Tempsetpoint,TVOCsetpoint,airquality,off(selectable) PolarityNO/NC(selectable) CO2(optional)TypeNon-dispersiveInfrared(NDIR) Accuracy±(30ppm+3%ofreading)(400-2000ppm),-10-50ºC,0-85%RH ±(50ppm+5%ofreading)(2000-5000ppm),-10-50ºC,0-85%RH >5000ppmconsultfactory Resolution1ppm Range0-2000PPM(Default)(Programmableupto10,000PPM) Responsetime90secondsto90%reading Samplerate1s TempandPressureCompensated.Barometricpressurealsoreadableovercommunications RelativeHumidity(optional)TypeDigitalCMOS Accuracy(2)±2%over0to80%RHrange Resolution0.05%RH HigherReliability,FasterInstallation,SuperiorAccuracy|SensetheDifference 866-660-8864|fax503-296-2529|www.senvainc.com 3Responsetime(3)30s Samplerate3s Operatingrange0to100%RH(non-condensing) Operatingconditions(4)-4to140oF(-20to60°C)@RH>90%;-4to176oF@RH=50% TemperatureTransmitter(optional) TypeSiliconBand-gap NominalAccuracy±0.3°C(operatingrange) MaximumAccuracy(2)±0.5°C(at25°C),±1.0°C Resolution0.01°C Responsetime30s Samplerate3s TVOC(optional)TypeMOS GasTotalVOC Range0-10,000μg/m3 ResponseTime<10s Temp,PressureCompensated Output0-2000μg/m3(default)Programmableupto10,000μg/m3 PMx(optional) CLASS1LASERPRODUCT TypeOptical SizeRangePM1.0,PM2.5,PM4.0,PM10.0 Scale0-1000μg/m3 Lowerdetectionlimit0.3μm Precision±10μg/m3(0-100μg/m3);±10%(100-1000μg/m3) OperatingEnvironmentTemperature-4to122oF(-20to50oC) Humidity0-95%non-condensing EnclosureMaterialABSPlastic Dimensions4.0”hx4.4”wx2.1”d (AQO:+2.8”solarshield) ComplianceAgencyCE,RoHS (1)Onesideoftransformer,secondaryisconnectedtosignalcommon.Dedicatedtransformerisrecommended. (2)ModelswithPMsensorincludedachieve ±5%accuracyover0to80%RHrangeandanadditionaltemperatureshiftofup+0.5°C (3)Timeforreaching63%ofreadingat25°Cand1m/sairflow (4)LongtermexposurestoconditionsoutsidenormalrangeathighhumiditymaytemporarilyoffsettheRHreading(+3%RHafter60hours.) *ProductimprovementisacontinualprocessasSenvaandproductfeaturesandspecificationmaychangewithoutpriornotice.Refertoinstructionsthataccompany theproductforinstallationandwiring. HigherReliability,FasterInstallation,SuperiorAccuracy|SensetheDifference 866-660-8864|fax503-296-2529|www.senvainc.com 4Next >