SE8300Room Controller Low Voltage Fan Coil Controller and Zone Controller Application specific controller with customizable covers and screen colours. The SE8300 is a low voltage fan coil terminal equipment controller suitable for commercial and high end hospitality markets. It can also be used as a zone controller. Compatible with SmartStruxure™ solution SmartStruxure Lite solutionSE8300 Room Controller Features AT A GLANCE Custom design • Touch screen interface • 2 casing options • Multiple fascia options • 5 selectable screen colors • Supports the upload of a custom standby screen • Supports the display of custom messages when integrated to a BACnet system • English, French, Spanish, Chinese, Russian and other selectable languages • Interchange between °C/°F • Advanced scheduling functions Options and accessories • On-board optional occupancy sensor (op- tional) • RH sensor with dehumidification control (optional) • Can be used with ZigBee Pro wireless sen- sors •ZigBee Pro communication module •CO 2 sensor communication module • Can be used with SC1300/SC2300 relay for mixed voltage applications 2 The perfect balance between simplicity and sophistication. Select from a wide variety of casings, fascias, and configurable screen colours to match decor. Display your own logo and custom messages on screen to reinforce your brand and provide a more enjoyable occupant experience. Introduction Smart energy management has never been easier than with the SE8300 series Fan Coil Room Controllers. Designed for new construction and retrofit projects, the Room Controllers dramatically decrease project delivery costs by reducing installation, configuration and commissioning time. No complex software or tools are required to customize functionality in order to meet your applications requirements. The Room Controllers provide all the advanced features and monitoring functions required by modern building automation systems in a simple compact enclosure. Application specific and programmable The SE8300 Room Controllers are both application-specific AND programmable. This enables the modification of pre-configured control sequences, or the creation of entirely new control sequences for HVAC, lighting and other applications. The Room Controllers are specifically designed to provide exceptional temperature control of multi-speed Fan Coil units. When compared to traditional building automation controllers, the SE8300 series Fan Coil Room Controllers provide unmatched return on investment. Touch screen with customizable user experience The touch screen of the SE8300 offers a customizable user experience with selection of languages, temperature scales, buttons, and screen colours. It also supports the upload of an image or logo that becomes the default standby screen of the device. Custom messages can also be displayed on-screen using BACnet ® objects when the SE8300 is integrated to a BACnet system. Selectable languages Select from the following 20 languages: English, French, Spanish, Chinese, Russian, Arabic, Czech, Danish, Dutch, Finnish, German, Hungarian, Indonesian, Italian, Norwegian, Polish, Portuguese, Slovak, Swedish and Turkish. Optional passive infrared motion sensor All models can be equipped with a discrete optional Passive Infrared (PIR) motion sensor. With the embedded sensor, the SE8300 uses advanced occupancy routines to generate automatic energy savings during occupied and unoccupied periods without sacrificing occupant comfort.Product Highlights • Suitable for both commercial and hospitality markets and systems • Customizable colour digital touch screen interface with multi-language support • Fully programmable control sequences using scripting • On board configuration interface utility • Configurable fan sequence of operation • Configurable Scheduler. • Change of value (COV) function for BMS integration. • Humidity sensor with on-board dehumidification strategy (model dependent) • Optional occupancy sensor • Advanced occupancy and scheduling functions for commercial and lodging applications • Optional wireless door and window switches (with optional ZigBee Pro ® card) available Supported Networking Protocols • BACnet MS/TP (B) (selectable) • Modbus (B) (selectable) • ZigBee Pro wireless mesh network (P) (optional) Integration to Schneider Electric Systems • SE8300 can be integrated to SmartStruxure™ Lite, SmartStruxure, and other Schneider Electric systems. • Wireless integration to MPM devices (P) • Wireless integration to BACnet IP, oBIX and EWS via MPM devices (P) • Direct wired integration to BACnet MS/TP (B) • Direct wired integration to Modbus (B) Architects can custom match styling to decor • Select from 2 casings and multiple fascias • Five screen colors are also selectable through the interface SE8300 Room Controller Features 3 CUSTOM STANDBY SCREEN & MESSAGES INTEGRATION > Custom standby screen > Custom BACnet MS/TP messages > Multiple fascias Dark black wood Silver finishGlossy white Light tan wood Dark brown wood White Brushed steel finish > 5 configurable screen color schemes > 2 casings White Silver BACnet MS/TP StruxureWare Building Operation Automation Server SE8300 StruxureWare Building Expert ZigBee Pro MPM deviceProgramming the SE8300 with Lua The SE8300 controllers are programmable using the open programming language Lua. Although building management systems often use open protocols and standards, their Program BACnet objects and scripting features remain proprietary and incompatible with third party devices. The SE8300’s use of an open language enables operability with all systems. Programming with BMS Integration When integrated into a BACnet MS/TP building management system, the SE8300 offers 10 Program BACnet objects able to contain 480 characters each. No special software, license or tool is required. • BACnet MS/TP integration into BMS • 10 Program BACnet objects (Lua scripts) • Each object can contain maximum of 480 characters Programming without Integration When there is no BACnet MS/TP integration, a Lua script can be uploaded directly into the SE8300 unit using the Uploader SE8000 tool. Unlike the 10 PG objects used when the unit is integrated via BACnet MS/TP, there is only one script, which can contain up to 16KB. • No BACnet MS/TP integration • 1 Lua script of 16KB max. • Uploader SE8000: upload scripts using this PC software tool and a USB/Micro-USB cable Applications: HVAC and Beyond Programming can be used to go beyond the pre-configured control sequences of the SE8300 to create customized HVAC applications. It can also be used to comply with specific project requirements and manage other applications, such as lighting and other equipment. Using Lua scripts also enables you to take advantage of the extra inputs and outputs of the SE8300 to manage other devices, such as sensors and relays. Uploader SE8000 Lua scripts, standby screen images and firmware upgrades can be loaded into the SE8300 using the Uploader SE8000 tool and a USB/Micro-USB cable. > PG objects of the SE8300 viewed through a BMS > PG objects of the SE8300 viewed through its touch- screen display SE8300 Room Controller Features 4SE8300 Room Controller Features Mixed-Voltage Applications SC1300/SC2300 The SE8300 can be used for mixed-voltage applications by incorporating a SC1300 (110/130 V) or SC2300 (220/240 V) mixed-voltage relay. For SC1300/SC2300 relay pack features, consult the SC1300/SC2300 specification sheet. SE8300 as a Zone Controller The SE83000 can also be used as a Zone Controller to control ON/OFF, floating, or 0 to 10 Vdc heating or cooling terminal equipment such as pressure dependent VAVs, Valves, and other end devices. The following list shows common Zone Controller applications: • Cooling only VVT zone with reheat • Fin-tube radiators • Cabinet heaters • Radiant panel heaters • Electric re-heat zones • Terminal reheat The above options are similar to those provided by the SE7200 series Room Controllers. 5 TYPICAL ZONE CONTROLLER APPLICATION Return air SE8300 Low Voltage Fan Coil Terminal Equipment Controller Cooling only VAV Heating coil To Difuser Baseboard Reheat Standard wired BACnet MS/TP communication and optional ZigBee Pro communicatio module upgrade BACnet MS/TP Wired communication protocol TYPICAL LOW VOLTAGE FAN COIL APPLICATION Return air SE8300 Low Voltage Fan Coil Terminal Equipment Controller 3 Speed fan Cooling coil Heating coil Supply air Existing field wires Filter status switchFan status switch Standard wired BACnet MS/TP communication and optional ZigBee Pro communication module upgrade Optional Wireless Accessories ZigBee® Pro Optional wireless communication SED-WDSDoor & Window Switch SED-CMSCeiling Mounted Motion Sensor SED-WMSWall Mounted Motion Sensor6 SE8300 Room Controller Specifications SE8300 Dimensions 12cm/4.72in (H) x 8.6cm/3.38in (W) x 2.5cm/1in (D) Power Requirements Input: 24VAC ±15%, 50/60Hz Input: 24 - 28VAC 50/60Hz (with CO 2 sensor module) Device consumption: up to 12 VA Transformer maximum rating: 100 VA, 4.17 A Output Ratings Relay rating: 28 Vac 50/60Hz, 1.0 Amp., in-rush = 3.0 Amps; pins 1, 2, 3, 4, 5, 8, 9 Digital optomos output rating: 28 Vac 50/60Hz, 0.3 Amp., in-rush = 1.5 Amps; pins 9, 10, 11, 12 Analog: 0 - 10 Vdc in 2 kilo-ohm resistance minimum load (maximum 5 mA); pins 9, 10, 11, 12 Operating Conditions 0 °C to 50 °C (32 °F to 122 °F) 0% to 75% R.H. non-condensing Storage Conditions -30 °C to 50 °C (-22 °F to 122 °F) 0% to 75% R.H. non-condensing Temperature Sensor Local 10 K NTC type 2 thermistor Temperature Sensor Resolution ± 0.1 °C (± 0.2 °F) Temperature Control Accuracy ±0.5 ° C (± 0.9 °F) @ 21 °C (70 °F) typical calibrated Humidity Sensor and Calibration Single point calibrated bulk polymer type sensor Humidity Sensor Precision Reading range from 10-90 % R.H. non-condensing 10 to 20% precision: 10% 20% to 80% precision: 5% 80% to 90% precision: 10% Humidity Sensor Stability Less than 1.0 % yearly (typical drift) Dehumidification Setpoint Range 30% to 95% R.H. Occ, Stand-By and Unocc Cooling Setpoint Range 12.0 to 37.5 °C (54 to 100 °F) Occ, Stand-By and Unocc Heating Setpoint Range 4.5 °C to 32 °C (40 °F to 90 °F) Room and Outdoor Air Temperature Display Range -40 °C to 50 °C (-40 °F to 122 °F) Proportional Band for Room Temperature control Cooling and Heating: Default: 1.8°C (3.2°F) Analog Inputs Modulating 0-10 VDC across UI19 to Common Binary Inputs Dry contact across terminals UI16, UI17 and UI19 to Common Remote Temperature Sensor Require- ments 10 K NTC type 2 thermistor Wire Gauge Power supply: 18 gauge or larger, Communications: 24 gauge or larger Approximate Shipping Weight 0.34 kg (0.75 lb) Safety Standards All Models LVD Directive 2006/95/EC EN 60950-1:2006/A2:2013UL 873 CSA C22.2 No. 24-93 EMC Standards All Models EMC Directive 2004/108/EC IEC 61326-1:2005 FCC 15 Subpart B ICES-003 Radio Standards (Wireless Models) R&TTE Directive 1999/5/EC ETSI EN 300 328 V1.8.1 ETSI EN 301 489-1 V1.9.2 ETSI EN 301 328 V1.8.1 FCC 15 Subpart C RSS 210 THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUD- ING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Specifications Check with your local government for instruction on disposal of these products. THIS PRODUCT FOR COMMERCIAL USE ONLY Room Controller Input Power Usage of the CO 2 sensor module within the Room Controller draws additional power. It is recommended when using the CO 2 sensor module, the site transformer be capable to accommodate the additional power consumption. Room Controller power consumption of 12 VA and input voltage range of 24 - 28 VAC is required. 25mm (0.99”) Dimensions 86mm (3.37”) 120mm (4.72”) * Note: SE8300 models shipped before September 17th 2014 have the following Output Ratings: Optomos output: 30 AC/DC, 0.5 Amp. (above 25 °C, reduce by 5mA/°C) Analog: 0 - 10 Vdc in 2 kilo-ohm resistance minimum load (maximum 5 mA) BO2 - Fan L BO3 - Fan M BO4 - Fan H RC (24 Vac) C (Common) RH BO8 UO9 UO10UO11UO12 BACnet + BACnet - BACnet REFUI 16UI 17Common UI 19UI 20 - RSCommonUI22 - SS 78 SE8300 Room Controller Ordering Information Ordering information SE83U5B0050 RH sensor and control -00 = No RH sensor or control -50 = RH sensor with dehumidification control PIR motion sensor -0 = No PIR -5 = PIR on board Casing and fascia -00 = Silver/Silver -11 = White/White (Replacement fascias available separately) Network -B = BACnet® MS/TP (ZigBee Pro communication module available separately) Replacement fascias (ordered separately) FAS-00 Silver FAS-01 White FAS-03 Glossy translucent white FAS-05 Light tan wood FAS-06 Dark brown wood FAS-07 Dark black wood FAS-10 Brushed steel finish Compatibility -U = Universal outputs ZigBee ® Pro communication module (ordered separately) VCM8000V5045P CO2 sensor communication module (ordered separately) VCM8001V5045 Part numbers SE8300 part numbers RH sensor & control PIR motion sensor Silver casing & fascia White casing & fascia SE8300U0B00x SE8350U0B00xx SE8300U5B00xx SE8350U5B00xxx SE8300U0B11x SE8350U0B11xx SE8300U5B11xx SE8350U5B11xxx Part numbers Communication modules and Fascias Consult their respective data sheets for the latest available part numbers and features Schneider Electric | SDS-SE8300-A4.EN.04.2017.v10 www.schneider-electric.com/buildings April 2017 VCM8000V5045P Module Versions All VCM8000 ZigBee Pro modules shipped after December 15, 2016 are Version 9 (V9) modules. The V9 module is required for the SE8300 Room Controller to activate functionality of the CO 2 Sensor Module. The SE8300 Room Controller must also be running Firmware version 1.5.1 to activate CO 2 Sensor Module functionality.Next >