Compatible withSmartStruxure™ solutionSmartStruxure Lite solutionRoom ControllerSE7600F Rooftop Unit with Modulating Heat ControllerThe SE7600F Rooftop terminal equipment room controller with modulating heat can make your building more comfortable while still meeting the ventilation codes for minimum building fresh air requirements. The easy-to-install SE7600F includes modulating heat functionality, which allows the addition of an extra supply air temperature control loop to better control and condition the supply air levels for a more comfortable occupant environment.2Schneider Electric | SDS-SE7600-EN.A4.08.2015.v2 www.schneider-electric.com/buildings August 2015The SE7600F is easy to install and includes modulating heat functionality, which allows for the addition of an extra supply air temperature control loop to better control and condition the supply air levels, providing a more comfortable occupant environment.IntroductionMaintaining fresh air requirements for buildings located in colder climates has always been a challenge. In low outdoor air temperature conditions, supply air is often too cold to be used directly without conditioning when no heating demand is present. This creates an uncomfortable environment for occupants that is difficult to control. RTU terminal equipment controllers for modulating heatThe SE7600F roof top terminal equipment room controller with modulating heat makes your building more comfortable while still meeting ventilation codes for minimum building fresh air requirements. The SE7600F is easy to install and includes modulating heat functionality. This allows for the addition of an extra supply air temperature control loop to better control and condition the supply air levels, providing a more comfortable occupant environment.This easy-to-install wall-mounted SE7600F room controller features an easy-to-read digital display and built-in commissioning and configuration utility, temperature sensor, optional humidity sensor, and optional Passive Infrared (PIR) occupancy sensor cover. Open protocol design provides compatibility to BACnet® MS/TP and wireless ZigBee® Pro network systems. Our network ready “stand-alone” versions can be field retrofit with optional communication modules that enable the SE7600F to be integrated into virtually any building automation system as building requirements change. No previous building automation training is required for the easy installation and commissioning process. Installation can be completed in fifteen minutes.SE7600F RTU with Modulating Heat FeaturesAT A GLANCE Custom design• Function with any open protocols• Network ready units can be retrofit in the field with optional communication modules• One simple wall-mounted device to install, wire, and commission• Application-specific controllers• No special software required• Fully embedded local configuration utilityOptions and accessories• PIR occupancy sensor• Advanced occupancy and monitoring functions• 7-day scheduling3Schneider Electric | SDS-SE7600-EN.A4.08.2015.v2 www.schneider-electric.com/buildings August 2015SE7600F RTU with Modulating Heat ApplicationsSimplified HMIUnique 5 button menu driven user interface simplifies programming and commissioning time during typical installation of unit.Outside air sensorBACnet MS/TPWired communication protocolSE7600ControllerControl BoardSupply air sensorTYPICAL APPLICATIONOutside airZigBee® ProOptional wireless communication Cooling coil Fan Heating coilReturn airSupply air4Schneider Electric | SDS-SE7600-EN.A4.08.2015.v2 www.schneider-electric.com/buildings August 2015SE7600F RTU with Modulating Heat SpecificationsDimensions12.5cm/4.9in (H) x 8.6cm/3.38in (W) x 2.9cm/1in (D)Power Requirements19-30Vac, 50/60 Hz; 2 VA (RC & C) Class 2RC to RH jumper 2.0 Amps 48 VA maximumOperating Conditions0 °C - 50 °C ( 32 °F - 122 °F )0% - 95% R.H. non-condensingStorage Conditions-30 °C - 50 °C ( -22 °F - 122 °F )0% - 95% R.H. non-condensingTemperature SensorLocal 10 K NTC thermistorTemperature Sensor Resolution± 0.1 °C ( ± 0.2 °F )Temperature Control Accuracy±0.5 ° C ( ± 0.9 °F ) @ 21 °C ( 70 °F ) typical calibratedOcc and Unocc Cooling Setpoint Range12.0 - 37.5 °C ( 54 - 100 °F )Occ and Unocc Heating Setpoint Range4.5 °C - 32 °C ( 40 °F - 90 °F )Room and Outdoor Air Temperature Display Range-40 °C - 50 °C ( -40 °F - 122 °F )Proportional Band for Room Temperature controlFactory set, heating and cooling at: 1.1°C ( 2.0°F )Digital InputsRelay dry contact only across C terminal to DI1 or DI2Contact Output RatingEach relay output: ( Y1, Y2, G, W1, W2 & AU )30 Vac, 1 Amp. maximum30 Vac, 3 Amp. in-rushModulating Heat, Analog Output Rating0 to 10 Vdc into 2KΩ resistance min.Wire Gauge18 gauge maximum, 22 gauge recommendedApproximate Shipping Weight0.75 lb (0.34 kg)Agency Approvals All ModelsUL: UL 873 (US) and CSA C22.2 No. 24 (Canada), File E27734 with CCN XAPX (US) and XAPX7 (Canada)Industry Canada: ICES-003 (Canada) FCC: Compliant to CFR 47, Part 15, Subpart B, Class A (US)CE: EMC Directive 89/336/EEC (Europe Union)C-Tick: AS/NZS CISPR 22 Compliant (Australia / New Zealand) Supplier Code Number N10696Agency Approvals Wireless ModelsFCC: Compliant to: Part 15, Subpart CTHIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDE-SIRED OPERATION. SpecificationsCheck with your local government for instruction on disposal of these products. Ordering informationSE7645Communication options:-B = BACnet® MS/TP-P = ZigBee Pro wireless-W = ZigBee® wireless- = Network readyProgrammability:-00 = No local scheduling / Non programmable-52= Local scheduling / programmablePIR options:-50 = PIR ready but PIR cover not included-55 = Factory assembled with PIR coverF* Some part number configurations may not be available. Next >