© 2016 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. Document Number: F-15479-13 www.schneider-electric.com schneider-electric.com | 1 Installation Instructions MP-3/4xx Series, MP-2/4xxx Series Reversible and Proportional Electric Actuators Application The MP series actuators are used fortwo-position, floating,and proportional control ofdampers, valves, and program switches in heating, ventilating, air conditioning, and similar applications. Hazardous locationmodelsoffer a sturdy cast aluminum casewith bolted cover. Theyhavetwo3/4" pipetappedopenings forjointswith rigid metal conduit. All wiring is brought outto separate terminals for ease of installation. These factoryenclosure and actuator assemblies are UnderwritersLaboratoriesListed. Features • Proportional actuators with built-in feedback potentiometers • Spring return and non-spring return models available • 24 Vac, 120 Vac, and 240 Vac models are available • Actuator has a rugged die cast aluminum housing with two 1/2” conduit openings. • Hazardous location actuator housing has two 3/4" pipe taped openings for rigid metal conduit connection • Oil-immersed motor and gear train * Refer to Table-5 to identify specific models that are in compliance with CE requirements. Typical MP6 (Hazardous Locations) Typical Spring Return Typical Non-Spring Return * Refer to Table-5 to identify specific models that are in compliance with CE requirements. Typical MP6 (Hazardous Locations) Typical -6xx Suffix (CP-8301-xxx or CP-8391-91x Installed)2 | schneider-electric.comInstallation Instructions December, 2017 tc © 2016 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. Document Number: F-15479-13 SPECIFICATIONS Actuator Inputs Input Control Signals:Refer to the actuator selection tables beginning on page 3 for input control signal capability versus specific actuator models. Floating,Requires one Single Pole Double Throw (SPDT) switch with floating (center off) position rated at 0.9 amps @ 24 Vac or two Single Pole Single Throw (SPST) switches rated at 0.9 amps @ 24 Vac. Two-Position, SPDTRequires snap acting switch rated at 0.9 amps @ 24 Vac. SPSTCan be used with certain spring return actuators. Switch must be rated to handle actuator power requirements. Barber-Colman Microtherm,Proportional Electrical systemwith the following typical controllers: PP-22x series, TP-1xx series, TP-2xx series, TP-3xx series, TP-4xx series, TP-1xxx series, and TP-1xxxx series. StandardControl of a single actuator. SequencingControl of two actuators in sequence. Five-PositionUsed typically for adjustable minimum position (five positions) of an economizer actuator. Slidewire and Paralleling,Requires AE-504 paralleling relay. Refer to AE-504 Solid State Paralleling Relay General Instructions F-16524. AE-504 accepts 100 Ω to 1000 Ω slidewires. Voltage Vdc,Requires CP-8301-xxx series of solid state actuator drives. Refer to CP-8301 Solid State Actuator Drive General Instructions F-14940. Refer to the actuator selection tables beginning on page 3. Current mAdc,Requires CP-8391-xxx series of solid state actuator drives. Refer to the actuator selection tables beginning on page 3. Power Requirements:Refer to the actuator selection tables beginning on page 3 to determine power requirements. Connections: MP-3xx, 4xx, 2xxx, 4xxx,Coded screw terminals. Models with “-600” Suffix,Coded screw terminals except for input signal which are color coded pigtails. Actuator Outputs Torque:Refer to the actuator selection tables beginning on page 3 to determine the actuator torque rating. Nominal Damper Area:Actuator selection should be made in accordance with the damper manufacturer’s specifications. Stroke (Degrees of Rotation),Refer to the actuator selection tables beginning on page 3 for information on degrees of rotation. Auxiliary Switch,Refer to the actuator selection tables beginning on page 3 for the models that include an auxiliary switch. Refer to Table-7 for ratings. Spring Return:Refer to the actuator selection tables beginning on page 3 for models that are spring return. Environment Ambient Temperature Limits: Shipping and Storage,-40 to 160 °F (-40 to 71 °C). Operating,-40 to 136 °F (-40 to 58 °C). Humidity:5 to 95% RH, non-condensing. Locations:NEMA 1. NEMA 4 for non-spring return actuators with AM-363. Optional hazardous locations models. Agency Listings: US Standard UL 873,Underwriters Laboratories (File #E9429 XAPX, Temperature Indicating and Regulating Equipment). Canadian Standard C22.2 No. 24: Underwriters Laboratories (File #E429 Category XAPX7, Temperature Indicating and Regulating Equipment). European Community,EMC Directive ( 2004/108/EC ). Low Voltage Directive ( 2006/95/EC ). Refer to Table-5 to identify specific models that are in compliance with CE requirements. Hazardous Location Models,UL file #E29291. Designed for use in hazardous IMAGE OR IMAGES IMAGE OR IMAGESschneider-electric.com | 3 Installation Instructions © 2016 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. December, 2017 tc Document Number: F-15479-13 F-15479-12 © Copyright 2012 Schneider Electric All Rights Reserved. locations N.E.C., Class 1, Groups C a nd D, and Class 2, Groups E, F, and G. Temperature code T6 for hazard o us housing. Actuators in the actuator selection tables below with “-600” suffix have the CP-8301-120 factory in stalled. All CP-8301s have a fixed span of 3 Vdc to drive the actuator fu ll stroke and a start point adjustable from 2 to 12 Vdc (factory set 6 Vdc). The CP-8391-91x series have a fixed r ang e of 4 to 20 mAdc to drive the actuator full stroke. Refer to CP-8391-910 Series 4 to 20 mA Electronic Actuator Drive General Instructions F-22453 . The CP-8391-716 has an adjustable span of 4 to 16 mAdc (factory set for 16) and adjustable start point of 2 to 16 mAdc (factory set for 4). The input signal on CP-8391-716 is optically isolated. Refer to CP-8391-716 Electronic Actuator Drive General Instructions F-21220 . Table-1MP-2xxx Series Model Chart . Table-2MP-3xx Series Model Chart. Actuator Part Number Internal Wiri ng (See Figure) Input Control Signal External Wiri ng (and required Interfac e Module th at must be purchased separately) (See Figure) Power Requirements Output Shaft Aux. Swi tch Built-in T rans- former b 2-Position SPST Spring Return 2-Position or Floating SP DT Barber-Colman Microtherm a (Proportional Electric) 135 to 1,0 00 Ω Slidewire Voltage Vdc Current mAdc Volts Hz. Amps Torque Lb.-i n. (N-m) Timing Sec onds (No Load) Degrees of Ro tation SpringReturn Standard Sequencing of T wo Actuators 5-Position (Adj. Min Position) MP-2113-500 Figure-27 – Figure-5 Figure-7 – – Figure-14 (AE-504) Figure-17 (CP-8301-024) Figure-19 (CP-8391-913) 24 60 2.2 50 (5.6) 25 180 (nonAdj.) No SPDT – MP-2150-500 Figure-29 – Figure-6 – – – Figure-15 (AE-504) Figure-18 (CP-8301-120) Figure-21 c or Figure-23 d 120 60 0.5 50 (5.6) 25 180 (non-Adj.) No SPDT Yes Actuator Par t Number Internal Wiri ng (See Figure) Input Control Signal External Wi ring (and required Interface Module that must be purchased separately) (See Figure) Power Requi rements Output Shaft Aux. Sw itch Built-in T rans- former b 2-Position SPST SpringReturn 2-Position or Fl oating SPDT Barber-Colman Microtherm a (Proportional Electric) 135 to 1, 000 Ω Slidewire Voltage Vdc Current mAdc Volts Hz. Amps Torque Lb. -in. (N-m) Timing Seconds (No Load) Degrees of Rot ation Spring Return Standard Sequencing of T wo Actuators 5-Position (Adj. Min Position) MP-361 Figure-24 Figure-3 Figure-5 Figure-7 – – Figure-14 (AE-504) Figure-17 (CP-8301-024) Figure-19 (CP-8391-913) 24 60 2.5 50 (5.6) 90 180 (Adj. e ) CW SPDT – MP-367 Figure-32 – – – Figure-11 – – – – 24 60 2.5 50 (5.6) 90 180 (Adj. e ) CW SPST – MP-371 Figure-24 Figure-3 Figure-5 Figure-7 – – Figure-14 (AE-504) Figure-17 (CP-8301-024) Figure-19 (CP-8391-913) 24 60 2.5 50 (5.6) 90 180 (nonAdj.) CCW SPDT – MP-377 Figure-32 – – – Figure-11 – – – – 24 60 2.5 50 (5.6) 90 180 (nonAdj.) CCW SPST – MP-379 Figure-30 – – – – Figure-12 – – – 24 60 2.5 50 (5.6) 90 180 (nonAdj.) CCW None – MP-381 Figure-24 – Figure-5 – – – Figure-14 (AE-504) Figure-17 (CP-8301-024) Figure-19 (CP-8391-913) 24 60 2.2 220 (24.9) 130 180 (Adj. e ) No SPDT – MP-382 Figure-24 – Figure-5 – – – Figure-14 (AE-504) Figure-17 (CP-8301-024) Figure-19 (CP-8391-913) 24 60 2.2 220 (24.9) 130 to 1300 (Adj.) 180 (Adj. e ) No SPDT – MP-387 Figure-32 – – – Figure-11 – – – – 24 60 2.2 220 (24.9) 130 180 (Adj. e ) No SPST – MP-389 Figure-30 – – – – Figure-12 – – – 24 60 2.2 220 (24.9) 130 180 (Adj. e ) No None – aTypical Barber-Colman Microtherm Controllers: PP-22x Series; TP -1xx S eries; TP-4xx Series; TP-101x Series; TP-103x Series; and TP-1xxxx Series. bUnits with a “-2-x” suffix, e.g. MP-xxxx-xxx-2-x, include a built-in transformer (used for Barber-Colman Microtherm or with AE -5 04) with secondary leads wired externally to terminals 7 and 8 of the actuator. Red (24 Vac) to terminal 8 and Blue (12 Vac) to terminal 7. When these actuators are used with contro lle rs other than Barber-Colman Microtherm or AE-504, disconnect th e Red and Blue leads and tape off. Note: Models prior to “-2-x” suffix had transformer wired directly to potentiometer. To disconnect the tr ansformer, remove the back plate of the actuator, disconnect and tape the transformer leads. cRequires CP-8391-910.dRequires CP-8391-716.eRotation adjustable 45 to 320 ° . Caution: On actuators with proportional inpu t signals changing the rotation will affect the control, since the internal feedb ack potentiometer’s travel is fixed. fMP-371 models with the “-621” suffix are obsolete.4 | schneider-electric.comInstallation Instructions December, 2017 tc © 2016 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. Document Number: F-15479-13 Table-3MP-4xx Series Model Chart. Actuator Part Number Internal Wiri ng (See Figure) Input Control Signal External Wiring (and requ ired Interfac e Module that must be purchased separately) (See Figure) Power Requi rements Output Shaft Aux. Swi tch Built-in T rans- former b 2-Position SPST Spring Return 2-Position or Fl oating SPDT Barber-Colman Microtherm a (Proportional Electric) 135 to 1, 000 Ω Slidewire Voltage Vdc Current mAd c Volts Hz. Amps Torque Lb. -in. (N-m) Timing Se conds (No Load) Degrees of Rot ation SpringReturn Standard Sequenc- in g of Two Actuators 5-Position (Adj . Min Position) MP-421 Figure-25 – Figure-6 – – – – Figure-16 (CP-8301-120) Figure-20 c or Figure-22 d 120 60 0.65 60 (6.8) 25 180 (Adj. e ) No SPDT – MP-422 Figure-25 – Figure-6 – – – – Figure-16 (CP-8301-120) Figure-20 c or Figure-22 d 120 60 0.65 60 (6.8) 25 to 250 (A dj.) 180 (Adj. e ) No SPDT – MP-423 Figure-25 – Figure-6 – – – – Figure-16 (CP-8301-120) Figure-20 c or Figure-22 d 120 60 0.65 60 (6.8) 13 90 (Adj. e ) No SPDT – MP-424 Figure-25 – Figure-6 – – – – Figure-16 (CP-8301-120) Figure-20 c or Figure-22 d 120 60 0.65 60 (6.8) 13 to 130 (A dj.) 90 (Adj. e ) No SPDT – MP-451 Figure-25 – Figure-6 – – – – Figure-16 (CP-8301-120) Figure-20 c or Figure-22 d 120 60 0.65 220 (24.9) 80 180 (Adj. e ) No SPDT – MP-452 Figure-25 – Figure-6 – – – – Figure-16 (CP-8301-120) Figure-20 c or Figure-22 d 120 60 0.65 220 (24.9) 80 to 800 (A dj.) 180 (Adj. e ) No SPDT – MP-453 Figure-25 – Figure-6 – – – – Figure-16 (CP-8301-120) Figure-20 c or Figure-22 d 120 60 0.65 220 (24.9) 40 90 (Adj. e ) No SPDT – MP-454 Figure-25 – Figure-6 – – – – Figure-16 (CP-8301-120) Figure-20 c or Figure-22 d 120 60 0.65 220 (24.9) 40 to 400 (A dj.) 90 (Adj. e ) No SPDT – MP-461-600 Figure-25 – 1.5 – – – – Figure-16 f – 120 60 0. 6 50 (5.6) 90 180 (Adj. e ) CW SPDT – MP-465 Figure-26 Figure-4 Figure-6 Figure-9 – – Figure-15 (AE-504) Figure-18 (CP-8301-120) Figure-21 c or Figure-23 d 120 60 0. 6 50 (5.6) 90 180 (Adj. e ) CW SPDT Yes MP-470 Figure-31 – – – – Figure-13 – – – 120 60 0. 6 50 (5.6) 90 180 (non-Adj.) CCW None Yes MP-471-600 Figure-25 – – – – – – Figure-16 f – 120 60 0. 6 50 (5.6) 90 180 (non-Adj.) CCW SPDT – MP-475 Figure-26 Figure-4 Figure-6 Figure-9 – – Figure-15 (AE-504) Figure-18 (CP-8301-120) Figure-21 c or Figure-23 d 120 60 0. 6 50 (5.6) 90 180 (non-Adj.) CCW SPDT Yes MP-480 Figure-31 – – – – Figure-13 – – – 120 60 0. 6 220 (24.9) 130 180 (Adj. e ) No None Yes MP-481-600 Figure-25 – – – – – – Figure-16 f – 120 60 0. 6 220 (24.9) 130 180 (Adj. e ) No SPDT – MP-483 Figure-26 – Figure-6 – – – Figure-15 (AE-504) Figure-18 (CP-8301-120) Figure-21 c or Figure-23 d 120 60 0. 6 220 (24.9) 65 90 (Adj. e ) No SPDT Yes MP-485 Figure-26 – Figure-6 – – – Figure-15 (AE-504) Figure-18 (CP-8301-120) Figure-21 c or Figure-23 d 120 60 0. 6 220 (24.9) 130 180 (Adj. e ) No SPDT Yes MP-486 Figure-26 – Figure-6 – – – Figure-15 (AE-504) Figure-18 (CP-8301-120) Figure-21 c or Figure-23 d 120 60 0. 6 220 (24.9) 130 to 1300 (A dj.) 180 (Adj. e ) No SPDT Yes MP-495 g Figure-26 – Figure-6 – – – Figure-15 (AE-504) Figure-18 (CP-8301-120) Figure-21 c or Figure-23 d 120 60 0.95 450 (50.9) 130 180 (Adj. e ) No SPDT Yes Footnotes for this table are listed on the following page.schneider-electric.com | 5 Installation Instructions © 2016 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. December, 2017 tc Document Number: F-15479-13 Table-4MP-4xxx Series Model Chart.Table-5 Actuator Part Numbers that are Compliant with CE Actuator Part Number Internal Wiring (See Figure) Input Control Signal External Wiring (and required Inte rface Module that must be purchased separately) (See Figure) Power Requirements Output Shaft Aux. Switch Built-in Trans- former b 2-Position SPST SpringReturn 2-Position or Floating SPDT Barber-Colman Microtherm a (Proportional Electric) 135 to 1,000 Ω Slidewire Voltage Vdc Current mAdc Volts Hz. Amps Torque Lb.-in. (N-m) Timing Seconds (No Load) Degrees of Rotation SpringReturn Standard Sequencing of Two Actuators 5-Position (Adj. MinPosition) MP5-4651 Figure-26 Figure-4 Figure-6 – – – Figure-15 (AE-504) Figure-18 (CP-8301-240) Figure-21 c or Figure-23 d 240 50 0.25 50 (5.6) 108 180 (Adj. f ) CW SPDT Yes MP-4701 Figure-31 – – – – Figure-13 – – – 240 60 0.25 50 (5.6) 90 180 (non-Adj.) CCW None Yes MP5-4751 Figure-26 Figure-4 Figure-6 – – – Figure-15 (AE-504) Figure-18 (CP-8301-240) Figure-21 c or Figure-23 d 240 50 0.25 50 (5.6) 108 180 (non-Adj.) CCW SPDT Yes MP-4851 Figure-26 – Figure-6 – – – Figure-15 (AE-504) Figure-18 (CP-8301-240) Figure-21 c or Figure-23 d 240 60 0.25 220 (24.9) 130 180 (Adj. f ) No SPDT Yes MP5-4851 Figure-26 – Figure-6 – – – Figure-15 (AE-504) Figure-18 (CP-8301-240) Figure-21 c or Figure-23 d 240 50 0.25 220 (24.9) 156 180 (Adj. f ) No SPDT Yes aTypical Barber-Colman Microtherm Controllers: PP-22x Series; TP-1 xx Series; TP-4xx Series; TP-1 01x Series; TP-103x Series; and TP-1xxxx Series. bUnits with a “-2-x” suffix, e.g. MP-xxx x-xxx-2-x, include a built-in transformer (used for Barbe r-Colman Microtherm or with AE -504) with secondary leads wired externally to te rminals 7 and 8 of the actuator. Red (24 Vac) to terminal 8 and Blue (12 Vac) to terminal 7. When these actuat ors are used with controllers other than Barber-Colman Microtherm or AE-504, disconnect the Red and Blue leads and tape off. Note: Models prior to “-2-x” suffix had transformer wired directly to potentiometer. To disconnect the tr ansformer, remove the back plate of the actuator, disconnect a nd tape the transformer leads. cRequires CP-8391-910.dRequires CP-8391-716.eRotation adjustable 45 to 320 ° . Caution: On actuators with proportional input signals changing the rotation will affect the control, since the internal feedb ack potentiometer’s travel is fixed. fIntegral solid state drive accepts 2-15 Vdc voltage.gMP-495 is not rated for UL or CSA MP-361-0-0-2MP-363-0-0-2MP-367-0-0-2MP-371-0-0-2MP-377-0-0-2MP-379-0-0-2MP-381-0-0-2MP-382-0-0-2MP-383-0-0-2MP-387-0-0-2MP-389-0-0-2 MP-481-600-0-2MP-481-691-0-2MP-481-692-0-26 | schneider-electric.comInstallation Instructions December, 2017 tc © 2016 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. Document Number: F-15479-13 Table-6Actuator Part Numbers for Hazardous Location Applications. Table-7Auxiliary Switch Ratings. Standard Actuator Part Numbers Hazardous Location Actuator Assemblies Part Numbers abc Damper ActuatorsValve Actuators d MP-381—MP6-381 MP-421—MP6-421 MP-423MP6-423— MP-453MP6-453— MP-483MP6-483— MP-485—MP6-485 MP-361—MP6-361 MP-367—MP6-367 MP-371—MP6-371 MP-377—MP6-377 MP-379—MP6-379 MP-465—MP6-465 MP-470—MP6-470 MP-475—MP6-475 MP5-4651—MP7-4651 MP5-4751—MP7-4751 a Class 1, Groups C & D, and Class 2, Groups E, F, and G hazardous locations; refer to EN-56-2. b Models for hazardous locations are only available as factory-built enclosure/actuator assemblies. c See standard actuator part number wiring diagrams for wiring terminations. d Hazardous location valve actuators can also be used for hazardous location damper applications. Switch Electrical Rating120 Vac240 Vac Running5.8 amps2.9 amps Locked Rotor34.8 amps17.4 amps Non-Inductive126schneider-electric.com | 7 Installation Instructions © 2016 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. December, 2017 tc Document Number: F-15479-13 Figure-1Part Number System for MP-2xxx-xxx-x-x Series Actuators. Note:This figure is for information only. Do not use it for ordering or selecting product. 5 -50 Hz 6 -Includes 60 Hz Hazardous Location Housing 7 -50 Hz Hazardous Location Housing 0 -No Transformer Unless Noted in Base Part Number 2 -Internal Transformer 3 -Old Engineering Revision A - Old Actuator (Eng. Revision) Ax10 -Old Actuator Equals - 110 as an Example AV5 -Old Actuator Equals - 205 as an Example 1xx -Specials 100 -AM-363 Installed 2xx -Unit Ventilator Specials 304 -AE-504 Installed 321 -AM 321 Installed 332 -AM-332 Installed 341 -AM-341 Installed 500 -Aux. Switch 600 -CP-8301-620 (CP-8301-120) Installed (120 Vac), No Aux. Switch CP-8301-624 (CP-8301-024) Installed (24 Vac), No Aux. Switch CP-8301-640 (CP-8301-240) Installed (240 Vac), No Aux. Switch 601 -CP-8301-620 (CP-8301-120) Installed (120 Vac), Aux. Switch CP-8301-624 (CP-8301-024) Installed (24 Vac), Aux. Switch CP-8301-640 (CP-8301-240) Installed (240 Vac), Aux. Switch 7xx -OEM Specials Voltage 0 -120 Vac 1 -240 Vac 2 -208 Vac 3 -24 Vac 1 -180 ° , No Transformer 3 -90 ° , No Transformer 5 -180 ° , Transformer 1800:1 Gear Train 50 Lb.-In. Torque 25 Sec./180 ° @ 60 Hz No Load Timing MPx-21xx-xxx-x-x Mechanical Stops Motor (Actuator) Proportional8 | schneider-electric.comInstallation Instructions December, 2017 tc © 2016 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. Document Number: F-15479-13 Figure-2Part Number System for MP-3xx, MP-4xx, or MP-4xxx Series Actuators. Note:This figure is for information only. Do not use it for ordering or selecting product. Gear Train (Torque/Timing* for 180 ° ) 1 -1025:1 (35 Lb.-In./13 Sec.) 2 -1960:1 (60 Lb.-In./25 Sec.) 3 -2980:1 (85 Lb.-In./35 Sec.) 4 -4018:1 (130 Lb.-In./50 Sec.) 5 -6760:1 (220 Lb.-In./80 Sec.) 6 -6760:1 Spring Return CW (50 Lb.-In./90 Sec.) 7 -6760:1 Spring Return CCW (50 Lb.-In./90 Sec.) 8 -10292:1 (220 Lb.-In./130 Sec.) 9 -10413:1 (450 Lb.-In./130 Sec.) *No Load @ 60 Hz. 1 -180 ° , Fixed Speed 2 -180 ° , Adj. Speed 3 -90 ° , Fixed Speed 4 -90 ° , Adj. Speed 5 -180 ° , Fixed Speed, Transformer 6 -180 ° , Adj. Speed, Transformer 7 -180 ° , Fixed Speed, Sequencing 8 -180 ° , Adj. Speed, 5-Position 9 -180 ° , Fixed Speed, 5-Position 0 - 180°, Fixed Speed, 5-Position, Transformer A -Old Actuator (Eng. Revision) Ax10 -Old Actuator Equals - 110 as an Example AV5 -Old Actuator Equals - 205 as an Example 1xx -Specials 100 -AM-363 Installed, Not Available on Spring Return Actuators 2xx -Unit Ventilator Specials 304 -AE-504 Installed 321 -AM-321 Installed 332 -AM-332 Installed 341 -AM-341 Installed 600 -CP-8301-620 (CP-8301-120) Installed (120 Vac) CP-8301-624 (CP-8301-024) Installed (24 Vac) CP-8301-640 (CP-8301-240) Installed (240 Vac) 7xx -OEM Specials Voltage 3xx -24 Vac 4xx -120 Vac 4xx1 -240 Vac 4xx2 -208 Vac MPx-xxxx-xxx-x-x 0 -No Transformer Unless Noted in Base Part Number 1 -Leeds Northrup Capacitor Start Motor with Internal Capacitor 2 -Internal Transformer 3 -Old Engineering Revision 5 -50 Hz 6 -Includes 60 Hz Hazardous Location Housing 7 -50 Hz Hazardous Location Housing Motor (Actuator) Proportionalschneider-electric.com | 9 Installation Instructions © 2016 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. December, 2017 tc Document Number: F-15479-13 ACCESSORIES Damper linkage accessories AM-111Crank arm for 5/16" (7.9 mm) diameter damper shaft AM-112Crank arm for 3/8" (9.5 mm) diameter damper shaft AM-113Crank arm for actuator or 1/2" (12.7 mm) diameter damper shaft AM-115Crank arm for 7/16" (11.1 mm) diameter damper shaft AM-116Splined crank arm for actuator AM-122Linkage connector, straight type AM-123Damper clip AM-1255/16" x 20" (7.9 mm x 0.5 m) damper rod AM-125-0485/16" x 48" (7.9 mm x 1.2 m) damper rod AM-132Ball joint connector AM-161Damper linkage kit AM-161-1Damper linkage kit AM-30190 degree mounting bracket Miscellaneous actuator accessories AM-321Two step switch kit AM-332Potentiometer kit AM-341Four step switch kit AM-342Two step switch and potentiometer kit AM-363NEMA 4 gasket kit for non-spring return actuators only Valve linkage for 50 lb.-in. minimum, 180 ° actuator AV-329Valve linkage for 2-1/2" and 3" VB-9323 AV-391Valve linkage for 15 to 50mm and 1/2" to 2” VB-72xx or VB-73xx (also valve linkage for obsolete 1/2” to 1-1/4" VB-92xx or VB-93xx) AV-392Valve linkage for obsolete 1-1/2" and 2" VB-92xx or VB-93xx AV-395Valve linkage for 65 and 80mm VB-9215 or VB-9315, and 2-1/2" to 4" VB-9213 or VB-9313 Valve linkage for 130 lb.-in. minimum, 180 ° actuator AV-330Valve linkage for 2-1/2" and 3" VB-9323 AV-352Valve linkage for 2-1/2" to 6" VB-921x or VB-931x, 4" to 6" VB-9323 AV-393Valve linkage for 15 to 50mm and 1/2” to 2” VB-72xx or VB-73xx (also valve linkage for obsolete 1/2" to 1-1/4" VB-92xx or VB-93xx) AV-394Valve linkage for obsolete 1-1/2" and 2" VB-92xx or VB-93xx AV-396Valve linkage for 65 and 80mm VB-9215 or VB-9315, and 2-1/2" to 4" VB-921x or VB-931x Valve Linkage for 50 lb.-in. MP6-xxx and MP7-xxx Hazardous Location Actuators AV-291 Valve linkage for ½ to 2" VB-7xxx valves assembled with hazardous location actuator assemblies. AV-295 Valve linkage for 2½ to 3" VB-9xxx valves assembled with hazardous location actuator assemblies. Valve Linkage for 220 lb.-in. MP6-xxx and MP7-xxx Hazardous Location Actuators AV-293 Valve linkage for ½ to 2" VB-7xxx valves assembled with hazardous location actuator assemblies AV-296 Valve linkage for 2½ to 3" VB-9xxx valves assembled with hazardous location actuator assembliesNext >