Discolsure© 2016 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. April, 2017 tc Document Number: F-27907-5 USA: +1 888-444-1311 Europe: +46 10 478 2000 Asia: +65 6484 7877 product.support@schneider-electric.com www.schneider-electric.com schneider-electric.com | 1 Specification Sheet MG350V Globe Valve SmartX Actuator Features • Bi-color LED status indication for motion indication, auto calibration, and alarm notification • Auto calibration provides precise control by scaling the input signal to match the exact travel of the valve stem • Proportional models with and without a position output signal with field selectable 2 … 10 Vdc and 0 … 10 Vdc input signals and selectable input signal action (reverse or direct acting) • Floating and two-position models available with and with- out a position output signal • Pulse width modulated (PWM) models with field-selectable 0.59 … 2.93 sec and 0.1 … 25.5 sec input signal ranges with a position output signal • Stall protected throughout stroke • Manual override with automatic release • Position feedback output signal models include field se- lectable 2 … 10 Vdc or 0 … 5 Vdc output signal • Removable wiring screw terminal with 1/2” conduit open- ing • Integral linkage and self-adjusting valve position indicator Product Description MG350V globe valve actuators are non-spring return electromechanical actuators for the control of two-way and three-way Globe Valves for fan coils, unit ventilators, reheat, cooling units, perimeter heating, and other applications. Proportional, Floating, and Pulse Width Modulated (PWM) models are available for direct mounting on 1/2” … 2” VB- 7000 Globe Valves. The MG350V actuators are also compat- ible with older field installed 1/2” … 1-1/4” VB-9000 Globe Valves as well as other valves (with the addition of AV-800 Globe Valve Adapters). Specifications Input Power and Ratings Part NumberInput SignalPosition Feedback Output Signal Approx. Timing in Seconds for 1/2” (12.7 mm) Stroke Max. Stroke in inch (mm) Force lbf (N) MG350V-24F Three-Wire Floating1-10221/32 (16.5)78 (350) MGF350V-24FP Three-Wire Floating, PWM 1, 2 2 … 10 Vdc, 0 … 5 Vdc 3 5121/32 (16.5)67 (300) MG350V-24M 2 … 10 Vdc, 0 … 10 Vdc 4 -10221/32 (16.5)78 (350) MGF350V-24MP2 … 10 Vdc, 0 … 10 Vdc, 4 … 20 mA 2 … 10 Vdc, 0 … 5 Vdc 3 5121/32 (16.5)67 (300) 1 Also compatible with two-position Form A 24 Vac/Vdc input signals. 2 Field-selectable 0.59 … 2.93 sec and 0.1 … 25.5 sec PWM ranges. 3 Field selectable. The 2 … 10 Vdc output signal range also includes an alarm signal (see the MGF350V-24FP, MG350V-24M, and MGF350V- 24MP Alarm Operation table). 4 Field Selectable. E9429 * *The CE mark indicates RoHS2 compliance. Please refer to the CE Declaration of Conformity for additional details.2 | schneider-electric.comSpecification Sheet Discolsure© 2016 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. April, 2017 tc Document Number: F-27907-5 Electrical Connections Power input, running with full load MGF350V-24FP, MG350V-24M, MGF350V-24MP 24 Vac, ±20% (Class 2 power supply), 50/60 Hz, 7.2VA, 20 … 29 Vdc, 3.5 W MG350V-24F24 Vac, ±20% (Class 2 power supply), 50/60 Hz, 5VA, 20 … 29 Vdc, 3.5 W Power input, holding MGF350V-24FP, MG350V-24M, MGF350V-24MP 24 Vac, ±20% (Class 2 power supply), 50/60 Hz, 1.2 VA (24FP 0.7W, 24M 0.4W, 24MP 0.5W) MG350V-24FActuator is unpowered when it is holding Internal power supply type MGF350V-24FP, MG350V-24M, MGF350V-24MPhalf wave MG350V-24Ffull wave Input signal impedance MG350V-24M and MGF350V- 24MP MGF350V-24MP 2 … 10 Vdc and 0 … 10 Vdc >100 kOhms 4 … 20 mA, 500 Ohms Input Signal Auto Calibration (MGF350V-24FP, MG350V-24M, MGF350V-24MP) Automatic span calibration to precisely match the stroke length of the valve (with a minimum stroke of 1/8” (3.2 mm) and a maximum stroke of 21/32” (16.5 mm). Floating Control Signal (MG350V-24F, MGF350V-24FP) SPST center off (floating) control contacts or one or two SPST control contacts, minimum rating of 250 mA at 24 V or one or two triacs must be able to switch 250 mA at 24 Vac, 1,100 Ohms input impedance Floating Input Signal Minimum Pulse Width (MG350V-24F)100 msec Position Feedback Output Signal (MGF350V-24FP, MGF350V- 24MP) 2 … 10 Vdc and 0 … 5 Vdc, 0.5 mA (field selectable) Conduit ConnectionRemovable 1/2” conduit opening plate Electrical ConnectionsRemovable terminal block, AWG 12 … 24, meets the requirements of cUL without the need of an electrical earth ground connection Mechanical LinkageLinkage for 1/2” … 2” VB-7000 and 1/2” … 1-1/4” obsolete VB-9000 Globe Valves included with actuator Manual Override3 mm hex wrench (not included with actuator), “tee” handle style recommended Mechanical Valve Posi- tion Indicator Graduated position indicator showing open to close with end point indicators Electrical Valve Status Indication Bi-color LED status indication for motion indication, calibration, and alarm notification. MG350V-24F does not include the calibration and alarm indication Speed MG350V-24 and MG350V-24M MG350-24FP and MGF350V-24MP 0.295” (7.5 mm) per minute 0.59” (15 mm) per minute Force MG350V-24F and MG350V-24M MG350-24FP and MGF350V-24MP 78 lbf (350 N) force 67 lbf (300 N) force EnclosurePlenum rated per UL 2043 YokeRugged die cast aluminum Weight1.6 lbs Environmental Operating Temperature Range For fluid up to 266 °F (130 °C): For fluid up to 281 °F (138 °C): For fluid up to 340 °F (171 °C): For fluid up to 400 °F (204 °C): 23 … 131 °F (-5 … 55 °C) 23 … 127 °F (-5 … 53 °C) 23 … 115 °F (-5 … 46 °C) 23 … 102 °F (-5 … 39 °C) Shipping / Storage Temp.-40 … 158 ˚F (-40 … 70 ˚C) Operating Humidity Range5 … 95% non condensing LocationNEMA 2 (IP 53) with proper mounting orientation Noise Level≤30 dB (A) @ 1 meter Agency Listings North America cUL-us LISTED mark (xapx & xapx7), per UL 60730-1 and -2-14 and CAN/CSA E60730-1 and -2-14 Automatic Electric Controls, NEMA 2, NEC class 2 FCC part-15 class B, Canadian ICES- 003, and ESA registered. Plenum rated per UL 2043. European Community CE mark, LVD directive [2014/35/EU) per EN IEC 60730-1 and -2-14 Automatic Electric Controls, protection class III SELV, EMC directive [2014/30/EU] per EN IEC 61000-6-2 and -6-3, IP53 Ingress Protection per EN IEC 60529 (prop- erly mounted), RoHS2 directive [2011/65/EC] and REACH directive [2006/1907/EC]. Australia, New Zealand RCM, Regulatory Conformance Mark, per ACMA (Australia) and RSM (New Zealand).. Russia, Kazakhstan, Belarus EAC, EurAsian Conformity Mark. Accessories AM-708 500 Ohm resistor for connection to 4 … 20 mA input signals for MG350V-24M (not required for MGF350V-24MP)schneider-electric.com | 3 Specification Sheet Discolsure© 2016 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. April, 2017 tc Document Number: F-27907-5 2.96 1.10 2.83 5.87 4.39 5.04 2.27 Dimensions Mounting The actuator enclosure is NEMA Type 2 rated in accordance with NEMA 250-2003 when mounted in any of the mounting orienta- tions shown below. For IEC 60529 the actuator is IP51 compliant when mounted down to 85˚ from vertical or IP53 compliant when mounted down to 60˚ from vertical. Allow 8” (203 mm) minimum clearance above the actuator valve assembly for removal and reattachment of the actuator to the installed valve and for removal of the electrical access compartment cover. IP51 and NEMA Type 2 Allowable Mounting Orientation IP53 and NEMA Type 2 Allowable Mounting Orientation 85° 85° 0 60° 60° 0 Cover LED DIP switches Side tab slot (also on other side) Removable wiring terminal block Removable ½” conduit opening plate (slide upward to remove) Actuator Diagram MG350V Installed on a VB-7000 Globe Valve End ViewSide View4 | schneider-electric.comSpecification Sheet Discolsure© 2016 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. April, 2017 tc Document Number: F-27907-5 Next >