The UbiquiSTAT is a feature rich, multi- purpose touchscreen thermostat for a wide variety of applications. This series of thermostats can be configured for a variety of conventional, heat pump, and modulating control applications. UbiquiSTAT TM BACnet® is a registered trademark of ASHRAE. | PRODUCT DATA SHEET Commercial BACnet Thermostat Models: US4010 - Single-Stage RTU / Zoning Thermostat US4020 - Multi-Stage RTU Thermostat US4040 - Advanced RTU Thermostat US4050 - Advanced Application Thermostat Wed Feb 1, 2017 09:20AM2 2800 Laura Lane Madison, WI 53562 | 800.288.9383 Fax: 608.836.9044 | www.tcsbasys.com v0717.1 TM • Configurable P+I relay stage anticipator • Setpoint setback based on DI • Network upgradeable firmware • Built-in equipment protection delays and sequencing • Programmable fan control -Auto/on/cool/recirculation modes for occupied and unoccupied -Adjustable recirculation -Fan proving with automatic retries • User management controls -Occupancy override enable/disable -Setpoint adjust range limit -Optional access code locks out on-screen programming • Outdoor air heating and cooling lockouts • Discharge air protection limits • Fahrenheit or Celsius temperature display • External time clock input/output • Adjustable delay on power up and occupancy • Stand-alone or network operation • Backup & Restore of all settings (DM-BR-B) • Powerful touchscreen user interface -Internal BACnet explorer -Quick start wizard -System test screen for rapid commissioning -Highly detailed status reporting and diagnostics -Service status indication with custom messaging -Calibration of temperature inputs -4.3” color touchscreen • BACnet BTL Listed (B-ASC) • Full-featured BACnet scheduling (SCHED-I-B) -5 Heat/Cool setpoint groups • Includes all TCS Basys SZ Series thermostat features -Includes many additional features and enhancements • 4 temperature inputs (1 built-in, 3 remote) -Outdoor, discharge, remote room -Configurable weighted averaging of built-in and remote room • Conventional or heat pump control • Discharge setpoint reset on modulating heat/cool control • Configurable Smart Recovery™ Features FEATURES Feature / Model4010402040404050 Stage Configuration: Total stages # [Heat # / Cool # / Configurable #] 2 [1/1/0]6 [2/2/2]6 [2/2/2]6 [2/2/2] Analog Inputs / Outputs (0-20mA or 4-20mA)0/20/01/12/2 Mixed Air on T1-aaa Model Specific Features:3 2800 Laura Lane Madison, WI 53562 | 800.288.9383 Fax: 608.836.9044 | www.tcsbasys.com v0717.1 TM • Built-in application programming with simple configuration • Advanced fan control -Recirculation mode to meet minimum fresh air requirements • Demand response setback • Door status response setback Applications Feature / Model4010402040404050 Conventional staging: heat / cool / selectable 1/1/02/2/22/2/22/2/2 Heat pump control: compressors / aux heat • Emergency heat • Cold climate automatic auxiliary heat switch- over w/compressor lockout 1/12/22/22/2 Analog Inputs CO ² control-- aa Humidity (RH) control---a Pressure control---- General purpose monitoring--aa Analog outputs Hot and chilled water valve control---a Zone damper control w/ reheata--- Economizer control--aa Demand ventilation (CO ² control)--aa Digital or Analog heat/cool changeover based control a--a Hot deck / Cold deck zone controla--a Mixing valve control--- a APPLICATIONS & SPECIFICATIONS Common application set: Model specific application set: Communications: RS-485 • Protocol: BACnet MS/TP • Baud Rates: 9600, 19200, 38400, 57600, 76800, 115200 • Wire: 22 AWG 3-conductor twisted/shielded Additional: Power Requirement • Input: 24V AC +15%, -5%, 50/60 Hz • Device Consumption: 10 VA max • Wire: 18 AWG 2-conductor Specifications4 2800 Laura Lane Madison, WI 53562 | 800.288.9383 Fax: 608.836.9044 | www.tcsbasys.com v0717.1 TM Additional: Mechanical • Exterior Dimensions: 6.7” x 4.9” x 1.4” • (171mm x 123mm x 37mm) • Color: Glossy white • Mounting: 1 gang (vertical or horizontal) & 2 gang • (4” x 4”) hole patterns, accepts #6 to #10 screws • Wiring Terminals: De-pluggable blocks with screw connections User Interface • 4.3” color touchscreen display • Backlight with auto-dimming Environmental • Operating temperature: 32F to 131F (0C to 55C) • Storage temperature: -22F to 176F (-30C to 80C) • Operating Humidity: 0 – 100% RH (non-condensing) • Air Quality: Non-corrosive (i.e. use remote sensor for applications such as pools) Specifications (CONT) SPECIFICATIONS (CONT) NOTE: All specifications subject to change without notice. Outputs Feature / Model4010402040404050 Relays: Type: SPST mechanical contact Contact Rating: 2A max @ 24V AC (50/60Hz) Wire: 18 AWG 5777 Analog Outputs: Range: 0-20mA or 4-20mA (programmable) Accuracy: ±0.2mA (1% of full scale) Resolution: 0.1mA Max Load: 1000Ù Wire: 18 AWG 2-conductor 2012 Auxiliary Power: (+P Terminal) Output: 24V DC, 100mA max Wire: 18 AWG 2-conductor twisted/ shielded --aa Inputs Feature / Model4010402040404050 Analog Inputs: Range: 0-20mA or 4-20mA (programmable) Accuracy: ±0.2mA (1% of full scale) Resolution: 0.1mA Wire: 18 AWG 2-conductor twisted/ shielded --12 3 Remote Temperature Inputs: Sensor Type: Pt1000 RTD, Alpha=0.00385 Ω/ Ω/°C Resolution: 0.1°F Accuracy: ±1°F Range: -40°F to 160°F Wire: 18 AWG 2-conductor twisted/shielded 1 Built-In Temperature Sensor: Sensor Type: Digital Resolution: 0.1°F Digital Accuracy: ±1°F Range: -40°F to 160°F 3 Digital Inputs: Type: Dry contact only (no voltage) Wire: 18 AWG 2 conductor Model specific specification set:5 2800 Laura Lane Madison, WI 53562 | 800.288.9383 Fax: 608.836.9044 | www.tcsbasys.com v0717.1 TM Product Family Part # Description UbiquiSTAT US4010 Single-Stage RTU / Zoning Thermostat UbiquiSTAT US4020 Multi-Stage RTU Thermostat UbiquiSTAT US4040 Advanced RTU Thermostat UbiquiSTAT US4050 Advanced Application BACnet Thermostat Room thermostats shall have a touchscreen display for programming, scheduling, and monitoring. The thermostat shall have a built-in 365-day time clock with full-featured BACnet scheduling (SCHED-I-B). Thermostats shall be of the low voltage type. Thermostats shall have a limited temporary setpoint adjustment, a local override feature, and remote override capability. The status of all outputs shall be monitored locally and available to view using the touchscreen display. An adjustable delay on power up shall be available for soft start of systems on power loss and upon occupancy schedule changes. The ability to edit operating control parameters shall be protected via a user-definable security access code. Thermostats must incorporate non-volatile memory, so that in the event of power loss, all programmed operating parameters shall be unaffected without the use of battery backup. All control functions shall continue in the event of any/all communication failures. Thermostats shall provide local communications in accordance with BACnet MS/TP ASHRAE 135. All BACnet objects and properties shall be published, open, and non-proprietary. Room thermostats shall be model UbiquiSTAT as manufactured by TCS. SUGGESTIONS, DIMENSIONS & ORDERING Specification Suggestion Dimensions Ordering6 2800 Laura Lane Madison, WI 53562 | 800.288.9383 Fax: 608.836.9044 | www.tcsbasys.com v0717.1 TM ACCESSORIES Accessories Carbon Dioxide Sensors Current Switches Platinum RTD Temperature Sensors Occupancy Sensors Photocell and Light SensorsHumidity TransmittersNext >