Max Cable Length 4,000 feet Min loaded driver output signal level ± 1.5v Driver load impedance (Ohms) 54 Receiver input voltage range -7v to + 12v Receiver input resistance (Ohms) ≥12k Connecting to the JENEsys Edge 534 with Monnit A 10/100-Mbit Ethernet connection is available on the JENEsys Edge 534 with Monnit. The RJ-45 port has two LEDs. When the device is connected to a network, the blue LED is lit and the blue LED flashes when activity occurs. Step 1: Connect one end of the Ethernet cable to your JENEsys Edge 53 4 with Monnit’s Primary RJ-45 port and the other end to the internet port on your computer. Step 2: Unplug the 3-position screw terminal (black) from the Power port on the JENEsys Edge 534 with Monnit. Step 3: Insert the positive wire from your 24 Vac, 50/60 Hz circuit to the termi nal marked on the screw terminal and tighte n down the screw. Step 4: Insert the negative wire from your 24 Vac, 50/60 Hz circuit to the terminal marked on the screw terminal and tighten down the screw. Step 5: Insert the ground wire from your 24 Vac, 50/60 Hz on the circuit to ground (far left terminal) marked screw terminal and tighten down the screw. Step 6: Plug the 3-position screw terminal connector back into the Power port on the JENEsys Edge 534 with Monnit. Step 7: Temporarily change your computer’s network settings so your IP address is in the range: to (without using the JENEsys Edge 534 with Monnit’s default address as described in Step 8). Make note of your computer’s current network settings. Step 8: With ProBuilder (Workbench) 4.9.1/4.7.110/4.6.96 installed on your computer, make a platform connection to the JENEsy s Edge 534 with Monnit using the factory default IP address (192.168.1.12n, where the last numeral (n) matches the last numeral in the JENEsys Edge 534 with Monnit’s Host ID number), platform daemon port (3011), and the following credentials: Username: tridium Password: niagara Step 9: Refer to the G ETTING S TARTED WITH N IAGARA 4 G UIDE and JENE SYS E DGE 534 –N4 U SER G UIDE for detailed instructions on how to configure it using Niagara 4. C onnecting RS-485 Networks to JENEsys Edge 534 with Monnit The RS-485 port uses a 3-position, screw terminal connector. The screw terminals (from left-to-right) are shield, negative (-), and positive (+). The transmit (Tx) and receive (Rx) LEDs located on the JENEsys Edge 534 with Monnit cover will flash when there is network activity detected. Step 1: Unplug 3-position screw terminal connector from the RS-485 port on the device. Step 2: Insert positive wire from your RS-485 network to positive terminal (far right terminal) on the 3-position, screw terminal connector and tighten down the screw. Step 3: Insert negative wire from your BACnet network to negative terminal (center terminal) on the 3-position, screw terminal connector and tighten down the screw. Please refer to the JENE SYS E DGE 534 WITH M ONNIT W IRING I NSTALLATION G UIDE for further wiring instructions and cautions. Step 4: Lynxspring recommends installing a 120-ohm end-of-line resistor on the positive (+) and negative (-) terminals. Step 5: Plug 3-position screw terminal connector back into the RS-485 port. ® I NSTALLATION G UIDE Package Contents of JENE-EG534-WL-M Estimated completion time: 5-10 minutes (1) JENEsys Edge 534 with Monnit (JENE-EG534-WL-M) This JENEsys Edge 534 with Monnit Installation Guide (1) JENEsys Edge 534 with Monnit Wiring Installation Guide (1) 15-Position Terminal Connector (blue) (3) 12-Position Terminal Connectors (2 black & 1 blue) (4) 3-Position Terminal Connectors (1 black, 1 gray & 2 blue) Preparing to Install Decide on the location/placement of your JENEsys Edge 534 with Monnit, ensuring its position is upward/vertical. You can use wall mounting screws (not provided) to mount the device in an open space or mount on a 35mm wide DIN rail utilizing the molded DIN rail slot located on the base of the device. Make sure the selected location is: Not in direct sunlight or near a heater or heating vent Not cluttered/crowded and sufficient clearance is available above and below the JENEsys Edge 534 with Monnit for proper ventilation and room for cables and wiring Well-ventilated (especially if enclosed in a cabinet) This device has been loaded with the bare minimum Niagara 4.2.36 software and requires the latest Onyxx Driver package to commission and update the controller's firmware. Be sure to download the N4 version of the Onyxx Driver at: resources.lynxspring.com. Physical Mounting to a DIN Rail For UL safety compliance this Lynxspring product shall be mounted inside enclosures with no openings below the device and if non-metallic, a flammability rating of at least HB. Step 1: Pull out the DIN rail clip and push down and in to force the DIN rail clip to snap over the other edge of the DIN rail. Step 2: To keep the JENEsys Edge 534 with Monnit from sliding on the DIN rail, secure it with clips provided by the DIN rail vendor, or place a screw in one of the mounting tabs in the base of the JENEsys Edge 534 with Monnit. Up to eight Onyxx XM 34IOs can be connected. See section: C ONNECTING O NYXX N ETWORKS TO JENE SYS E DGE 534 WITH M ONNIT for details. To remove the device(s) from a DIN rail, insert a screwdriver in center plastic locking tab and pull downwards, then lift the unit outwards. Made in USA Ethernet Cable Connection from device to computer 24Vac/dc Power RS-485 Network NOTE: Corporate Headquarters 2900 NE Independence Ave Lee’s Summit, MO 64064 P: 816-347-3500 | F: 816-347-0780 Specifications Operating System Helixx ® by Lynxspring ® and Niagara 4.9.1/4.7.110/4.6.96 Processor 1 GHz AM335x ARM Cortex A-8 Memory 512 MB DDR3L 800 MHz, 4 GB 8-bit Embedded MMC on- board Flash Real-Time Clock (RTC) Battery-powered clock included to store description/setup values including year, month, date, hours, minutes and seconds 2 Ethernet Ports 10/100 Mbps (RJ-45 Connector) RS-485 Port Optically isolated RS-485 serial port with 3-screw connector Mini B-USB USB Client Connector utilizes 5-pin Mini-B USB cable Micro USB Serial shell access Onyxx Network 3-wire (LxH LxL SHLD) high-speed differential serial signal Antenna Reverse-polarity SMA antenna connector 16 Universal Inputs Type-3 10 K ohm thermistors; resistance 0-100 K ohms; 0-10 Vdc; 0-20 mA using a 499-ohm resistor; pulse input: up to 500 Hz; 12-bit A/D resolution 10 Digital Outputs Form A contacts, 24 V at 0.5 A 8 Analog Outputs 0-10 Vdc Connector Screw Size 3/32” slotted Supported Wire Size 28-16 AWG Housing UL94V-0 Power Input External 24 Vac/dc +10%/-10%, 50/60 Hz, minimum 18 VA/ device Construction Base: Plastic, DIN rail or screw mount Cover: Plastic Cooling Internal air convection Dimensions (without antenna) 4.5” (11.43 cm) width x 12.25” (31.16 cm) length, including unfolded antenna x 9.0” (22.86 cm) depth, including folded antenna Mounting Flat panel and 35 mm DIN rail mounting options standard Operating Temperature Range 0 – 60 °C (32 –140 °F) Storage Temperature Range 0 – 70 °C (32 –158 °F) Relative Humidity Range 5 – 95% RH, non-condensing Compliance Approved: FCC 47 CFR Parts 15C and 18, EN 55022, EN 55011, ICES-003, RoHS, UL 916, CSA C22.2 No. 205-17, EN 61010-1: 2010, IEC 61010-1, 3rd edition; Monnit radio FCC ID: ZTL-G2SC1 Revised 11/30/2021 | JENE-EG534-WL-M-IG-V1.3 Connecting Onyxx Networks (Onyxx XM 34IO to JENEsys Edge 534 with Monnit) Step 1: Unplug 3-position screw terminal connector (gray) from port marked LxH, LxL and SHLD on the JENEsys Edge 534 with Monnit. Step 2: Insert a wire between LxH terminal (far left terminal) on the 3-position screw terminal connector of each device and tighten down the screw. Step 3: Insert a wire between LxL terminal (center terminal) on the 3-position screw terminal connector of each device and tighten down the screw. Step 4: Insert the shield wire between SHLD terminal (far right terminal) on the 3-position screw terminal to connect of each device and tighten the screw. Step 5: If the Onyxx XM 34IO is located at the end of the network, Lynxspring recommends installing a 120 ohm end-of-line resistor on the LxH and LxL terminals. Step 6: Plug 3-position screw terminal connector back into the port marked LxH, LxL and SHLD on the JENEsys Edge 534 and Onyxx XM 34IO as needed. Troubleshooting If you are unable to make a platform connection to the JENEsys Edge 534 with Monnit: Make sure the JENEsys Edge 534 with Monnit is fully up and running. The power LED should turn on and the heartbeat LED should be flashing. Make sure the Ethernet cable is connected firmly to the primary Ethernet port on the JENEsys Edge 534 with Monnit. The LEDs on the Ethernet port will indicate if the JENEsys Edge 534 with Monnit is connected to the network. The amber LED will indicate the JENEsys Edge 534 with Monnit is connected to a network, and the green LED will indicate the JENEsys Edge 534 with Monnit is transmitting and receiving on the network. If you are connecting directly from your computer to the JENEsys Edge 534 with Monnit ensure your computer’s network settings are set so that your computer’s IP address is anything other than the device, in the same subnet. Close and re-open the browser to make sure that the browser did not cache the previous page. Statement of Conditions In the interest of improving internal design, operational function, and/or operability, Lynxspring reserves the right to make changes to the product described in this document without notice. Lynxspring does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein. Technical Support Thank you for selecting Lynxspring products. Please contact our Support Team with any questions about installing or setting up your new JENEsys Edge 534 with Monnit (JENE-EG534- WL-M). support@lynxspring.com | toll free: 877-649-5969 Proper Disposal This product contains a lithium battery. The U.S. Environmental Protection Agency (EPA) does not regulate the disposal of batteries in small quantities; large quantities are regulated under the Universal rules of Hazardous Waste regulations (40 CFR PART 273). Lithium batteries are not currently being collected by manufacturers for recycling. While there are no federal regulations for disposal of lithium batteries, individual states can establish their own guidelines for battery disposal and should be contacted for any local disposal guidelines. The shipment of live or discharged lithium batteries is governed by the Department of Transportation (DOT) in their Code of Federal Regulations (49 CFR), paragraph 173.185(j). Remember that before any type of disposal the batteries should be discharged completely. Tape the contacts with electrical tape and package so as to prevent contacts accidentally coming together at any time. NOTICE: All information contained herein is, and remains the property of Lynxspring, Incorporated. The intellectual and technical concepts contained herein are proprietary to Lynxspring, Incorporated and may be covered by U.S. and Foreign Patents, patents in process, and are protected by trade secret or copyright law. Dissemination of this information or reproduction of this material is strictly forbidden unless prior written permission is obtained from Lynxspring Incorporated. Lynxspring ® , JENEsys ® , JENEsys Edge® , Onyxx ® and Helixx ® are registered trademarks of Lynxspring, Inc. Niagara Framework ® is a registered trademark of Tridium, Inc. The information and/or specifications published here are current as of the date of publication of this document. Lynxspring, Inc. reserves the right to change or modify specifications without prior notice. The latest product specifications can be found by contacting our corporate headquarters in Lee’s Summit, Missouri. Products or features contained herein are covered by one or more United States or foreign patents. Other brand and product names are trademarks or registered trademarks of their respective holders. This document may be copied by parties who are authorized to distribute Lynxspring products in connection with distribution of those products, subject to the contracts that authorize such distribution. It may not otherwise, in whole or in part, be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form without prior written consent from Lynxspring, Inc. Complete Confidentiality, Trademark, Copyright and Patent notifications can be found at: http://resources.lynxspring.com. This symbol was placed in accordance with the European Union Directive 2002/96 on the Waste Electric and Electronic Equipment (the WEEE Directive). If disposed of within the European Union, this product should be treated and recycled in accordance with the laws of your jurisdiction implementing the WEEE Directive. Next >