JENE-PC8000 - Wi-Fi Enabled EMBEDDED IOT CONTROLLER PRODUCT DATA SHEET Page 1 framework ® powered by Overview The JENE-PC8000 is a compact, embedded Internet of Things (IoT) controller and server platform for connecting multiple and diverse devices and sub-systems. With Internet connectivity and Web-serving capability, the JENE-PC8000 controller provides integrated control, supervision, data logging, alarming, scheduling and network management. It streams data and rich graphical displays to a standard web browser via an Ethernet or wireless LAN, or remotely over the Internet. The licensing model for the JENE-PC8000 controller is simplified and features standard drivers along with optional I/O and field bus expansion modules for ultimate flexibility and expandability. The JENE-PC8000 controller operates with Niagara 4, the latest version of the Niagara Framework ® , for optimum performance. Applications A JENE-PC8000 is ideal for any size facility. In larger facilities, multi-building applications and large-scale control system integrations, Niagara 4 Supervisors can be used with JENE-PC8000 controllers to aggregate information, including real-time data, history and alarms, to create a single, unified application. Features •Platform: TI AM3352: 1000MHz ARM ® Cortex™-A8 •Standard: Two RJ-45 Ethernet Ports, two RS-485 Ports •Interoperable: Supports BACnet ® , LonWorks ® , FOX, Modbus ® , oBIX, SNMP, and legacy protocols. •Versatile: Fully-customizable with an array of software drivers and custom modules. •Reliable: 1GB DDR3 SDRAM and removable micro-SD card with 4GB flash total storage/2GB user storage. •Fast: Onboard 1GB Ethernet communication provides rapid data transmission. •Expandable: Add up to 16 optional 16 point remote I/O modules. •Implementation: Stand-alone application control, energy management, and multi-protocol integration.JENE-PC8000 EMBEDDED IOT CONTROLLER Page 2 Specifications PLATFORM Operating System ProcessorTI AM3352: 1000MHz ARM ® Cortex™-A8 Memory 1GB DDR3 SDRAM Removable micro-SD card with 4GB flash total storage/2GB user storage Real-Time ClockYes Secure BootYes Niagara AX VersionRuns Niagara 4.1 and later COMMUNICATION PORTS Ethernet Port(2) RJ-45 10/100MB Ethernet ports RS-485 Port(2) isolated RS-485 with selectable bias and termination USB PortUSB type A connector (Back-up and restore support) Wi-Fi (Client or WAP) IEEE802.11a/b/g/n IEEE802.11n HT20 @ 2.4 GHz IEEE802.11n HT20/HT40 @ 5GHz Configurable radio (Off, WAP, or Client) WPAPSK/WPA2PSK supported CHASSIS ConstructionBase: Plastic, DIN rail or screw mount options. Cover: Plastic CoolingInternal air convection Dimensions7.05” (179mm) W x 4.33” (110mm) H x 2.41” (51.1mm) D ENVIRONMENT Operating Temperature Range-20 to 60°C (32 to 122°F) Storage Temperature-40 to 70°C (32 to 158°F) Storage Relative Humidity Range5% to 95%, non-condensing Shipping & VibrationASTM D4169, Assurance Level II MTTF10 Years+ AGENCY LISTINGS Compliance UL 916 CE EN 61326-1 FCC Part 15 Subpart B, Class B FCC Part 15 Subpart C C-UL listed to Canadian Standards Association (CSA) C22.2 No. 205-M1983 “Signal Equipment” 1999/5/EC R&TTE Directive CCC SRRC RSS ROHS POWER Power Supply24VAC/DC power supply BatteryBatteryless EXPANSION MODULES SUPPORTED NPB-8000-LON: 4Max 4 NPB-8000-232: 4Max 4 NPB-8000-2X-485: 2Max 2 I/O MODULES SUPPORTED J-T-IO-16-485Max 16JENE-PC8000 EMBEDDED IOT CONTROLLER Page 3 Dimensions 6.74" (171.1) 4.33" (110) 6.38" (162) 7.05" (179) 0.34" (8.6) 0.165" Dia. (4.2) 3.31" (84) 3.31" (84) 2.07" (52.5) 2.41" (61.1) 2.13" (54) 2.13" (54) 6.74" (171.1) 1.77" (45) 2.40" (61) 2.19" (55.5) 4.33" (110) 1 2 3 Mounting Instructions JENE-PC8000 Controller. Allow at least 1.5" (38mm) clearance around all sides and minimum 3" (76mm) at bottom for Wi-Fi antenna. Expansion module. Up to four (4) may be used. See "Expansion Modules and I/O Modules Configurations". Distances between center of tabs from one unit to another unit. 1 2 3 Compatible with (DIN43880) enclosures Suitable for mounting to a panel or to an EN50022 standard 35mm railJENE-PC8000 EMBEDDED IOT CONTROLLER Page 4 Expansion Modules and I/O Modules Configurations Maximum Combinations EXPANSION EXPANSION EXPANSION EXPANSION 232 or LON 232 or LON 232 or LON 232 or LON 485 485 232 or LON 232 or LON 232 or LON 485 485 485 485 232 or LON 485 485 485 485 1234 1 2 34JENE-PC8000 EMBEDDED IOT CONTROLLER Page 5 Ordering Information JENE-PC8000 NIAGRA 4 CONTROLLERS PART NUMBERPART DESCRIPTION JENE-PC8000 Demo Base unit includes two isolated RS-485 ports, two RJ-45 10/100MB Ethernet ports, USB Backup & Restore, Wi-Fi connectivity, all available Lynxspring drivers and a 500 device license. Hardware Accessories purchased separately JENE-PC8005 JENE-PC8000 Controller with 5 Device Core & 250 Points. Includes standard open drivers. Supports up to 5 devices or 250 points. Requires Niagara 4.0 or higher. JENE-PC8005-SMA-1YR-INIT JENE-PC8005 - Initial 18 month maintenance must be purchased in conjunction with initial controller purchase. Optional 3 or 5 year maintenance may be substituted. JENE-PC8010 JENE-PC8000 Controller with 10 Device Core & 500 Points. Includes standard open drivers. Supports up to 10 devices or 500 points. Requires Niagara 4.0 or higher. JENE-PC8010-SMA-1YR-INIT JENE-PC8010 - Initial 18 month maintenance must be purchased in conjunction with initial controller purchase. Optional 3 or 5 year maintenance may be substituted. JENE-PC8025 JENE-PC8000 Controller with 25 Device Core & 1,250 Points. Includes standard open drivers. Supports up to 25 devices or 1,250 points. Requires Niagara 4.0 or higher. JENE-PC8025-SMA-1YR-INIT JENE-PC8025 - Initial 18 month maintenance must be purchased in conjunction with initial controller purchase. Optional 3 or 5 year maintenance may be substituted. JENE-PC8100 JENE-PC8000 Controller with 100 Device Core & 5,000 Points. Includes standard open drivers. Supports up to 100 devices or 5,000 points. Requires Niagara 4.0 or higher. JENE-PC8100-SMA-1YR-INIT JENE-PC8100 - Initial 18 month maintenance must be purchased in conjunction with initial controller purchase. Optional 3 or 5 year maintenance may be substituted. JENE-PC8200 JENE- PC8000 Controller with 200 Device Core & 10,000 Points. Includes standard open drivers. Supports up to 200 devices or 10,000 points. Requires Niagara 4.0 or higher. JENE-PC8200-SMA-1YR-INIT JENE-PC8200 - Initial 18 month maintenance must be purchased in conjunction with initial controller purchase. Optional 3 or 5 year maintenance may be substituted. DEVICE PACKS (OPTIONAL CAPACITY UPGRADE PACKS - AVAILABLE AT THE TIME OF PURCHASE OF THE INITIAL CORE SOFTWARE) PART NUMBERPART DESCRIPTION DEVICE-10Up to 10 devices/500 point upgrade (can be purchased during initial licensing) DEVICE-25Up to 25 devices/1,250 point upgrade (can be purchased during initial licensing) DEVICE-50Up to 50 devices/2,500 point upgrade (can be purchased during initial licensing) DEVICE-UP-10Up to 10 devices/500 point upgrade (can be purchased post initial licensing) DEVICE PACKS (OPTIONAL CAPACITY UPGRADE PACKS - AVAILABLE AFTER PURCHASE OF THE INITIAL CORE SOFTWARE) PART NUMBERPART DESCRIPTION DEVICE-UP-25Up to 25 devices/1,250 point upgrade (can be purchased post initial licensing) DEVICE-UP-50Up to 50 devices/2,500 point upgrade (can be purchased post initial licensing) I/O MODULES PART NUMBERPART DESCRIPTION J-T-IO-16-485 Remote I/O module, compatible with the JENE-PC8000 controller. Communication using RS-485, maximum I/O supported J-T-IO-16-485 modules: 16 EXPANSION MODULES PART NUMBERPART DESCRIPTION JENE-PC8000-485Add on dual port RS-485 module JENE-PC8000-LONAdd on single port LON FTT10A module JENE-PC8000-232Add on single port RS-232 moduleJENE-PC8000 EMBEDDED IOT CONTROLLER Page 6 DRIVERS PART NUMBERPART DESCRIPTION DR-CCN-N4Carrier Comfort Network Niagara 4 driver. STATION PACKS PART NUMBERPART DESCRIPTION JENE-PC8000-AXEnables JENE-PC8000 controller to run Niagara AX (3.8U). 3.8U Build with JENE-PC8000 controller support. POWER SUPPLY OPTIONS PART NUMBERPART DESCRIPTION JENE-PC-PWR24V power supply for J-T-IO-16-485 JENE-PC-PWR-UNUniversal power supply for J-T-IO-16-485 JENE-PC-WWPM-120Universal power supply for JENE-PC8000 controller MAINTENANCE (INCLUDES NEW AND INTERIM RELEASES FROM ONE (1) YEAR FROM PURCHASE DATA) PART NUMBERPART DESCRIPTION JENE-PC8005-1YRJENE-PC8005 - 1 year maintenance. JENE-PC8005-3YRJENE-PC8005 - 3 year maintenance JENE-PC8005-5YRJENE-PC8005 - 5 year maintenance. JENE-PC8010-1YRJENE-PC8010 - 1 year maintenance. JENE-PC8010-3YRJENE-PC8010 - 3 year maintenance JENE-PC8010-5YRJENE-PC8010 - 5 year maintenance. JENE-PC8025-1YRJENE-PC8025 - 1 year maintenance. JENE-PC8025-3YRJENE-PC8025 - 3 year maintenance JENE-PC8025-5YRJENE-PC8025 - 5 year maintenance. JENE-PC8100-1YRJENE-PC8100 - 1 year maintenance. JENE-PC8100-3YRJENE-PC8100 - 3 year maintenance JENE-PC8100-5YRJENE-PC8100 - 5 year maintenance. JENE-PC8200-1YRJENE-PC8200 - 1 year maintenance. JENE-PC8200-3YRJENE-PC8200 - 3 year maintenance JENE-PC8200-5YRJENE-PC8200 - 5 year maintenance. *All JENE-PC8XXX parts include a Niagara 4 license and Lynxspring’s standard driver suite. Please see Lynxspring standard driver suite documentation for more details.JENE-PC8000 EMBEDDED IOT CONTROLLER JENEsys ® is a registered trademark of Lynxspring, Inc. Niagara Framework ® is a registered trademark of Tridium, Inc. www.lynxspring.com 877-649-5969 | sales@lynxspring.com JENEsys ® Platform The JENEsys ® platform (building operating system) is an open, unified, operational and informational system that combines equipment and device connectivity, integration and interoperability, supervision and control, energy management, visualization and actionable information (data & analytics) into a single, integrated architecture within a cyber-secured environment. JENEsys ® is scalable and allows organizations to continually build off the same network deployment and add additional applications as desired. The deployment of JENEsys ® hardware and software is the method by which building automation is expertly configured to a client’s best needs. JENEsys ® enables users to deploy optimal energy and facility operational strategies, capitalize on accurate and concise intelligence relating to the performance of their facilities, reduce energy consumption and costs, gain knowledge of individual usage and trends related to their building systems and equipment from one source, all within a cloud or hosted environment. •Choice – eliminates building managers and owners from being held captive to proprietary, closed technologies •Enables multi-vendor integration and interoperability between devices from different manufacturers and disparate systems •Flexibility/Options – allows facility managers, operators and owners to purchase different products from different manufacturers and choose the solutions that best fit their specific needs •Simplifies facility operations – users can manage all of their diverse systems via a single, easy-to-use, web-based interface •Combines the capabilities of network management, protocol conversion, distributed control, and the user interface into a single software solution that can operate on a wide range of hardware platforms from the very small to the very large •API’s are available to enable independent third parties to develop complementary, enterprise applications that can work effectively with the system •Data from the system is easily stored and retrieved from a common database and can be used throughout the system •Future Expansion – offers support for a wide range of applications and the scalability to easily add future service and product upgrades •Building managers and operators can continue to work with the products and vendors they trust, while gaining all the benefits of an integrated and interoperable system •Provides operational efficiencies that reduce business risk •Makes it easier to control and manage buildings and realize facility operational efficiencies, ensure occupant comfort and code compliances •Reduces system complexity and costs. Maximizes lifetime value of building systems and equipment •One platform that can be supported by whatever vendor or vendors a building owner, operator or facility manager chooses 1 4 7 * 2 5 8 0 3 6 9 # LAN/WAN Building SecurityEnergy Management Utility MeteringAsset Monitoring HVAC Lighting Card Access & Intrusion CCTV DVR Open ADR & Generation Plant Control Firewall INTERNET AX Supervisor Command & Control Remote ProBuilder or Browser Building Automation LYNX CyberPro™ Key Cyber Security Remote Applications Graphical User Interface Energy Analytics & Exception Reporting © 2020 Lynxspirng, Inc. ALL RIGHTS RESERVED Rev. 11-10-2020 JENE-PC8000-DS-V1.1Next >