34-636-763, Rev. D FANs 977, 1628.3 Product/Technical Bulletin VA-7010 Issue Date 0216 © 2016 Johnson Controls, Inc. 1 Part No. 34-636-763, Rev. D www.johnsoncontrols.com Code No. LIT-977360 VA-7010 Series Electric On/Off Actuator The VA-7010 Series Electric On/Off Actuators provide two-position (open/closed) control and can easily be field mounted with a threaded coupling onto VG5000 Series Forged Brass Valves. Refer to the VG5000 Series Forged Brass Valves 1/2 Through 1 in., Two-Way Normally Closed and Three-Way Product/Technical Bulletin (LIT-977135) for specific information. A lever at the side of the actuator housing can be used to open the mounted valve manually for servicing. Figure 1: VA-7010 Actuator with VG5000 Valve Features and Benefits Low or Line Voltage Model Available Provides application flexibility AC Stall Type Motor Ensures quiet operation Manual Lever Allows manual position mode for servicing Flat Profile Design with Small Side Clearance Provides mounting close to flat surfaces; saves space Actuator can be Mounted after Valve Body is InstalledSimplifies installation in confined spaces; allows application flexibility Actuator can be Rotated after Mounting Provides easier wiring by locating the wiring conduit entry in any direction 2 VA-7010 Series Electric On/Off Actuator Product/Technical Bulletin Operation When power is applied to the actuator, the motor drives the gear assembly, and pushes down on the valve stem against the force of the valve return spring. When power is removed from the actuator, the actuator retracts and allows the valve return spring to move the valve stem up, in the direction of its normal position. (See Figure 2.) 2-way N.O., PDTC3-way, MixingValve Type2-way N.C., PDTO= Flow= No FlowStem Movement/FlowActuator OffActuator OnActuator OnActuator OnActuator OffActuator Off Note: Push Down to Close (PDTC) Push Down to Open (PDTO) Figure 2: Flow Diagram Manual Override The VA-7010 actuator features a manual operating lever (shown in Figure 3) for manually opening Normally Closed (N.C.) valves or the N.C. port of 3-way valves. The lever will not fully close Normally Open (N.O.) valves or the N.O. port of 3-way valves. Dimensions Figure 3: Dimensions, in. (mm) Mounting Observe the following recommendations when mounting the actuator: Make sure the actuator is easily accessible for the electrical connections. Make sure the actuator is free of thermal insulation material. Leave at least 0.8 in. (20 mm) clearance above the actuator for mounting purposes. (See Figure 3.) To mount the actuator on a VG5000 valve: 1 Place the threaded coupling over the valve stem and the bonnet. 2. Rotate the actuator to the desired position and tighten the coupling securely by hand. Note: Never use the actuator as a mounting lever. ! CAUTION: Risk of Property Damage. Mount the actuator housing only on a valve that is piped 90 of the vertical position so that it is free of dripping water. Failure to do so could lead to water entering the housing and damaging the mechanism and motor. MISE EN GARDE : Risque de dégâts matériels. Montez l’actionneur uniquement sur une vanne raccordée à 90° de la position verticale de manière à éviter les écoulements d’eau. Le non-respect de cette précaution peut entraîner des infiltrations dommageables pour le mécanisme et le moteur. Figure 4: Valve/Actuator Mounting Positions VA-7010 Series Electric On/Off Actuator Product/Technical Bulletin 3 Wiring ! WARNING: Risk of Electric Shock. When servicing the actuator, make sure that the electrical supply to the actuator is turned off. Do not attempt to connect or disconnect wires when power is applied to the actuator. Failure to do so can cause electric shock and may result in severe personal injury or death. AVERTISSEMENT : Risqué de décharge électrique. En cas d’intervention sur l’actionneur, assurez-vous que l’alimentation électrique est coupée. N’essayez pas de brancher ou débrancher les câbles quand l’actionneur est sous tension. Le non-respect de cette précaution peut entraîner une décharge électrique et provoquer des blessures graves voire mortelles. ! CAUTION: Risk of Property Damage. Do not apply power to the system before checking all wiring connections. Short circuited or improperly connected wires may result in permanent damage to the equipment. MISE EN GARDE : Risque de dégâts matériels. Ne pas mettre le système sous tension avant d'avoir vérifié tous les raccords de câblage. Des fils formant un court-circuit ou connectés de façon incorrecte risquent d'endommager irrémédiablement l'équipement. IMPORTANT: Make all wiring connections in accordance with the National Electrical Code and all local regulations. To wire the VA-7010 actuator: 1. Run the actuator wires through 3/8 in. Flexible Metallic Conduit (FMC) or its equivalent as appropriate. 2. Secure the FMC to the connector provided with the actuator by tightening the clamp screw using a 1/4 in. flat-blade screwdriver. 3. Connect the wires as shown in Figure 5 for each respective model voltage. WhiteWhiteWhiteBlackGreenWhiteYellowGreenWhiteRedGreenWhiteBlueGreenPowerPowerCaseGroundN/AVA-7010Power24VAC120VAC230VAC208VAC277VAC Figure 5: VA-7010 Wiring Diagram Ordering Information VA-7010-8001236724 VAC120 VAC230 VAC208 VAC277 VACSupply Voltage Figure 6: Ordering Data for the VA-7010 Actuator Combinations The VA-7010 Series Electric Valve Actuators are designed to be used with the VG5000 valve series. Refer to the VG5000 Series Forged Brass Valves Product/Technical Bulletin (LIT-977135) for complete ordering information. 4 VA-7010 Series Electric On/Off Actuator Product/Technical Bulletin Specifications Product VA-7010 Series Electric On/Off Actuator Action On/Off Type of Motor Synchronous Stall Supply Voltage (50/60 Hz) VA-7010-8001: 24 VAC, Class 2, ±10% VA-7010-8002: 120 VAC, ±10% VA-7010-8003: 230 VAC, ±10% VA-7010-8006: 208 VAC, ±10% VA-7010-8007: 277 VAC, ±10% Power Consumption 7 VA Minimum Force 20.2 lb (90 N) Nominal Stroke 0.12 in. (3 mm), maximum 0.2 in. (5 mm) Full Stroke Time On Nominal 10 seconds Full Stroke Time Off Nominal 5 seconds Enclosure IP40, NEMA 1 Ambient Operating Condition 35 to 122F (2 to 50C), non-condensing Ambient Storage Condition -4 to 149F (-20 to 65C), non-condensing Electrical Connections 18 AWG, 20 in. (508 mm) long wire leads Dimensions (H x W x D) 2.9 x 2.9 x 2.6 in. (75 x 75 x 65 mm) Shipping Weight 1.1 lb (0.5 kg) Agency Compliance UL 873 Listed, File E27734, Guide XAPX, Plenum Rated CSA C22.2 No. 139 Certified, File LR85083, Class 3221 01 CE Conformity VA-7010-8001: CE Mark – Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. European Single Point of Contact: NA/SA Single Point of Contact: APAC Single Point of Contact: JOHNSON CONTROLS WESTENDHOF 3 45143 ESSEN GERMANY JOHNSON CONTROLS 507 E MICHIGAN ST MILWAUKEE WI 53202 USA JOHNSON CONTROLS C/O CONTROLS PRODUCT MANAGEMENT NO. 22 BLOCK D NEW DISTRICT WUXI JIANGSU PROVINCE 214142 CHINA Building Efficiency 507 E. Michigan Street, Milwaukee, WI 53202 Metasys® and Johnson Controls® are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. © 2016 Johnson Controls, Inc. VA-7010 Series Electric On/Off Actuator Product/Technical Bulletin 5 Next >