The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls shall not be liable for damages resulting from misapplication or misuse of its products. © 2020 Johnson Controls. www.johnsoncontrols.com 1 F4-CGM/FX-PCX Standard Control Panel Assembly Catalog Page Code No. LIT-1901131 Issued February 2020 Description The General Purpose Application MS/TP Controller (CGM) and Input/Output (I/O) Module (PCX) control panel is a pre-wired, preassembled standard control panel containing a Facility Explorer® CGM controller. Some models also include a FX-PCX I/O Module. This predesigned solution saves time and money by avoiding expensive and time-consuming field installations and inspections. In addition, you can tailor the assembly to a variety of common applications for additional savings. The control panel is shipped complete, mounted in either a NEMA 1 or NEMA 3R steel enclosure. In addition to the controllers, every assembly contains a power supply incorporating a 5 A circuit breaker, a 96 VA 120/24 VAC transformer, and two 120 VAC outlets. Some models include an optional second 96 VA 120/24 VAC transformer. The CGM/FX-PCX Standard Control Panel Assembly also includes a five- or ten-point 24 VAC distribution terminal block that allows for termination of additional field mounted devices. All models have a F4- CGM09090 controller, which communicates through BACnet® MS/TP or wireless Zigbee® networks and integrates with Johnson Controls® and third-party systems. Designated models also include a PCX Module, an FX-DIS1710-0 remote mount display, or terminal blocks. Some models offer additional space in the panel along with a section of DIN rail to mount relays or transducers or other approved ancillary devices. Sub-panel assemblies are the complete internal portion of the panel without the enclosure. It contains all of the same components as a comparable standard panel but it is just the perforated sub-panel with all components already mounted. This is a popular option if it is critical to preserve the panel mounting location in the designated installation area using an empty enclosure and then add the sub-panel later. Features •Consistent layout for all standard control panel solutions simplifies installation and commissioning. •Power supply with resettable circuit breaker and transformer provides high- and low-voltage protection. •Space and DIN rail reserved for future component additions allows for easy field upgrades to the panel. •Prebuilt, pre-wired, and pretested in an ISO-9001-2015 manufacturing facility provides products of consistently high quality. •UL 508A rated control panel and UL 50 Canadian Standards Association (CSA) approved enclosure meets local and national code requirements for the United States and Canada (cULus listed). •California Office of Statewide Health Planning and Development (OSHPD) Special Seismic Certification Preapproved control panel assembly meets standards for rigid and flexible mounting conditions to account for unit-mounted and remote-mounted application. •Controller with color-coded and clearly labeled screw terminals provides easily identifiable input/output points at the controller. Repair information If the F4-CGM/FX-PCX Standard Control Panel Assembly fails to operate within its specifications, replace the unit. For a replacement assembly, contact the nearest Johnson Controls representative . Selection charts Components included with the F4-CGM/FX-PCX Standard Control Panel Assembly QuantityDescription 1Metal enclosure, NEMA 1 or NEMA 3R 1F4-CGM09090-0 Programmable controller 1 FX-PCX1711-0, FX-PCX2711-0, FX-PCX2721-0, FX-PCX3721-0, FX-PCX3731-0 or FX-PCX4711-0, if applicable 1FX-DIS1710-0 remote mount display, if applicable 196 VA 120/24 VAC power supply with 5 A primary circuit protection and two 120 VAC outlets, standard on all panels 196 VA 120/24 VAC transformer with secondary protection, if applicable 1Five- or ten-point 24 VAC distribution terminal block 1 1.All panels with a single power supply ship with a five-point terminal block. Panels with an additional transformer ship with a ten-point terminal block. Panels — 16 x 20 enclosure- NEMA 1 Product code number Description P2AAN-BB001N00F4-CGM09090-0 controller panel mounted in a 16 in. W x 20 in. H x 6-5/8 in. D enclosure P2AAY-BB001N00F4-CGM09090-0 controller panel mounted in a 16 in. W x 20 in. H x 6-5/8 in. D enclosure with remote display Panels — 20 x 24 enclosure - NEMA 1 (Part1of2) Product code number Description P2BAN-BB001N00F4-CGM09090-0 controller panel mounted in a 20 in. W x 24 in. H x 6-5/8 in. D enclosure P2BAN-BB002N00F4-CGM09090-0 controller panel mounted in a 20 in. W x 24 in. H x 6-5/8 in. D enclosure with additional 96 VA transformer F4-CGM/FX-PCX Standard Control Panel Assembly The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls shall not be liable for damages resulting from misapplication or misuse of its products. © 2020 Johnson Controls. www.johnsoncontrols.com 2 F4-CGM/FX-PCX Standard Control Panel Assembly Catalog Page (Continued) P2BAY-BB001N00F4-CGM09090-0 controller panel mounted in a 20 in. W x 24 in. H x 6-5/8 in. D enclosure with remote mount display P2BAN-BBFD1N00F4-CGM09090-0 controller and FX-PCX1711-0 module panel mounted in a 20 in. W x 24 in. H x 6-5/8 in. D enclosure P2BAN-BBFC2N00F4-CGM09090-0 controller and FX-PCX2711-0 module panel mounted in a 20 in. W x 24 in. H x 6-5/8 in. D enclosure with additional 96 VA transformer P2BAN-BBFF2N00F4-CGM09090-0 controller and FX-PCX2721-0 module panel mounted in a 20 in. W x 24 in. H x 6-5/8 in. D enclosure with additional 96 VA transformer P2BAN-BBFG2N00F4-CGM09090-0 controller and FX-PCX3721-0 module panel mounted in a 20 in. W x 24 in. H x 6-5/8 in. D enclosure with additional 96 VA transformer P2BAN-BBFA2N00F4-CGM09090-0 controller and FX-PCX4711-0 module panel mounted in a 20 in. W x 24 in. H x 6-5/8 in. D enclosure with additional 96 VA transformer Panels — 24 x 24 enclosure - NEMA 1 Product code number Description P2CAN-BB001Y00F4-CGM09090-0 controller panel mounted in a 24 in. W x 24 in. H x 6-5/8 in. D enclosure with terminal blocks Panels — 24 x 36 enclosure - NEMA 1 Product code number Description P2DAN-BB001N00F4-CGM09090-0 controller panel mounted in a 24 in. W x 36 in. H x 6-5/8 in. D enclosure P2DAY-BB001N00F4-CGM09090-0 controller panel mounted in a 24 in. W x 36 in. H x 6-5/8 in. D enclosure with remote mount display P2DAN-BB001Y00F4-CGM09090-0 controller panel mounted in a 24 in. W x 36 in. H x 6-5/8 in. D enclosure with terminal blocks P2DAN-BBFF2N00F4-CGM09090-0 controller and FX-PCX2721-0 module panel mounted in a 24 in. W x 36 in. H x 6-5/8 in. D enclosure with additional 96 VA transformer P2DAN-BBFG2N00F4-CGM09090-0 controller and FX-PCX3721-0 module panel mounted in a 24 in. W x 36 in. H x 6-5/8 in. D enclosure with additional 96 VA transformer P2DAN-BBFH2N00F4-CGM09090-0 controller and FX-PCX3731-0 module panel mounted in a 24 in. W x 36 in. H x 6-5/8 in. D enclosure with additional 96 VA transformer P2DAN-BBFA2N00F4-CGM09090-0 controller and FX-PCX4711-0 module panel mounted in a 24 in. W x 36 in. H x 6-5/8 in. D enclosure with additional 96 VA transformer P2DAY-BBFA2N00F4-CGM09090-0 controller and FX-PCX4711-0 module panel mounted in a 24 in. W x 36 in. H x 6-5/8 in. D enclosure with additional 96 VA transformer with remote mount display P2DAN-BBFA2Y00F4-CGM09090-0 controller and FX-PCX4711-0 module panel mounted in a 24 in. W x 36 in. H x 6-5/8 in. D enclosure with terminal blocks P2DAN-BBFE2N00F4-CGM09090-0 controller and FX-PCX1711-0 and FX-PCX4711-0 modules panel mounted in a 24 in. W x 36 in. H x 6-5/8 in. D enclosure with additional 96 VA transformer and terminal block Panels — 20 x 24, 24 x 36 enclosure- NEMA 3R Product code number Description P2BCN-BBFA2N00F4-CGM09090-0 controller and FX-PCX4711-0 module panel mounted in a 20 in. W x 24 in. H x 8 in. D NEMA 3R enclosure with additional 96 VA transformer P2DCN-BB002N00F4-CGM09090-0 controller panel mounted in a 24 in. W x 36 in. H x 8 in. D NEMA 3R enclosure P2DCN-BBFA2N00F4-CGM09090-0 controller and FX-PCX4711-0 module panel mounted in a 24 in. W x 36 in. H x 8 in. D NEMA 3R enclosure with additional 96 VA transformer Sub-panel for 16 x 20 enclosure Product code number Description S2A0N-BB001N00Sub-panel assembly with F4-CGM09090-0 controller for use in a 16 in. W x 20 in. H x 6-5/8 in. D enclosure S2A0Y-BB001N00Sub-panel assembly with F4-CGM09090-0 controller for use in a 16 in. W x 20 in. H x 6-5/8 in. D enclosure with remote display Sub-panel for 20 x 24 enclosure Product code number Description S2B0N-BB001N00Sub-panel assembly with F4-CGM09090-0 controller for use in a 20 in. W x 24 in. H x 6-5/8 in. D enclosure S2B0N-BBFD1N00Sub-panel assembly with F4-CGM09090-0 controller and FX-PCX1711-0 module for use in a 20 in. W x 24 in. H x 6-5/8 in. D enclosure S2B0N-BBFD1N00Sub-panel assembly with F4-CGM09090-0 controller and FX-PCX2721-0 module for use in a 20 in. W x 24 in. H x 6-5/8 in. D enclosure with additional 96 VA transformer S2B0N-BBFA2N00Sub-panel assembly with F4-CGM09090-0 controller and FX-PCX4711-0 module for use in a 20 in. W x 24 in. H x 6-5/8 in. D enclosure with additional 96 VA transformer Panels — 20 x 24 enclosure - NEMA 1 (Part2of2) Product code number DescriptionThe performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls shall not be liable for damages resulting from misapplication or misuse of its products. © 2020 Johnson Controls. www.johnsoncontrols.com 3 F4-CGM/FX-PCX Standard Control Panel Assembly Catalog Page (Continued) Technical specifications Sub-panel for 24 x 24 enclosure Product code number Description S2C0N-BB001Y00Sub-panel assembly with F4-CGM09090-0 controller for use in a 24 in. W x 24 in. H x 6-5/8 in. D enclosure with terminal blocks Sub-panel for 24 x 36 enclosure Product code number Description S2D0N-BB001N00Sub-panel assembly with F4-CGM09090-0 controller for use in a 24 in. W x 36 in. H x 6-5/8 in. D enclosure with terminal blocks S2D0N-BBFA2N00Sub-panel assembly with F4-CGM09090-0 controller and FX-PCX4711-0 module for use in a 24 in. W x 36 in. H x 6-5/8 in. D enclosure with additional 96 VA transformer S2D0N-BBFA2Y00Sub-panel assembly with F4-CGM09090-0 controller and FX-PCX4711-0 module for use in a 24 in. W x 36 in. H x 6-5/8 in. D enclosure with additional 96 VA transformer and terminal block F4-CGM/FX-PCX Standard Control Panel Assembly TerminalsController mounted removable screw termination Wire sizeGround wire: 14 AWG; Transformer wires: 16 AWG Enclosure ratingNEMA 1 or NEMA 3R Enclosure finishANSI 61 gray polyester powder coating (perforated panel and enclosure) Ambient operating condition32°F to 122°F (0°C to 50°C) 10% to 90% RH Dimensions (width x height x depth) 16 in. W x 20 in. H x 6-5/8 in. D (406 mm W x 508 mm H x 168 mm D) 20 in. W x 24 in. H x 6-5/8 in. D (508 mm W x 610 mm H x 168 mm D) 24 in. W x 24 in. H x 6-5/8 in. D (508 mm W x 610 mm H x 168 mm D) 24 in. W x 36 in. H x 6-5/8 in. D (610 mm W x 914 mm H x 168 mm D) NEMA 3R: 20 in. W x 24 in. H x 8 in. D (508 mm W x 610 mm H x 203.2 mm D) NEMA 3R: 24 in. W x 36 in. H x 8 in. D (610 mm W x 914 mm H x 203.2 mm D) Ambient storage condition-40°F to 176°F (-40°C to 80°C) 5% to 95% RH Agency complianceControl Panel: UL 508A and CAN/CSA C22.2 No.14 Rated (cULus listed); Enclosure UL 50 Rated, CSA Approved OSHPD Special Seismic Certification Preapproval: OSP-0140-10 California Building Code (CBC) - 2013, International Building Code (IBC) - 2012 Seismic Performance Characteristics: S DS (g) = 2.26, z/h = 1.0, I p = 1.5Next >