Project JCI Partner Date Engineering Contractor Equipped with advanced I/O including Fireman’s Override and damper control, the BAS was designed from the ground up for easy integration with automation systems. With a 200 to 600V input and 1-40A adjustable overload, the BAS is the right starter for almost any job. Designed for ease of integration with automation systems • Comprehensive inputs/outputs for building automation systems • Reduces installation costs • High reliability patented superior motor protection • Electronic overload protection including locked rotor, cycle fault and maximum time to start (due to mis-sized motor or overload) • FLA out of calibration indication--ensures installer sets overload correctly based on calculated motor size Advanced control inputs eliminate interposing relays • Three dry inputs for auto-run, permissive auto and shutdown • Two voltage inputs (12-250VAC) for auto run and fireman’s override Logging retains critical information • Logging information is obtainable for starter failure (Factory retrievable only) • Last 10 start conditions, including FLA setting, max inrush, run current, time to start, and safety start mode. • Last 10 fault conditions, including FLA setting, fault type, fault current, and run time. Universal application • Automatically detects voltage • (200 to 600VAC) • Converts to 24V for control power UL Type 1 and 3R enclosures • Lockable enclosure • 3R features lockable keypad cover • Type 4 & 4X enclosure options available (consult factory) BMMS Series Building Management Motor Starter Smartstart ® Smartstart ® The Technology behind Smartart ® Smart - Start safely even without calibration! patented technology predicts a safe operating range for your motor based on the measured in-rush current Intelligent - detects if your starter needs to be calibrated, protecting you from operators trying to overcome motor jams or problems by over-setting the overload. With Smartstart enabled, if the starter isn’t in range, it alarms and trips notifying you before damage occurs Active - detects harmful extended starting conditions with maximum time to start. Monitors motor inrush current conditions and trips if the motor doesn’t start within 10 seconds (class 10 overload) regardless of FLA setting. Ingenious - Active current monitoring provides superior protection against locked rotor and stall conditions, tripping faster than a standard inverse trip curve, regardless of the FLA setting! Thoughtful - “Blackbox” recording feature retains critical information on last ten faults and starts (factory retrievable only). Smartstart ® Smartstart ® Hand/Off/Auto keypad with LED status indicators • Intuitive operation and control with Hand (manual run), Off, and Auto run modes Combination versions include disconnect • Motor circuit protection disconnect provides short circuit protection • High interrupting ratings for maximum electrical system compatibility • No fuses required • Lockable handle for safety H1H4 L3L1L2 MTR T1T3 AUX CONT M T2 OL 3PH 43 44 31 32 BMMS STARTER POWER WIRING A1 A2 BMMS CONTROL WIRING Motor Limit Switch Normally Open Input Actuator Control 24VDC, 1A Output Dry Inputs Relay OutputsCommon Fault Status Fireman’s Override 12-250VAC/DC Input Auto Run Permissive Shut Down Auto Run 12-250VAC/DC Input Voltage Inputs Contactor Coil 1 FLA (A) 5 10 15 20 25 30 35 40 PCB Power H1H4 Keypad Overload Setting Normally Open Input Normally Open Input Normally Closed Input P nal) 24V Output to contactor coil -600 VAC ut L1L2L3 T1T3T3 L1L2L3 T1T2T3 BMMS Wiring Diagrams LIT-1901076Project JCI Partner Date Engineering Contractor BMMS Series Motor Starter (Continued) Part Number UL HP Ratings SCIC KAIC @ Contactor NEMA Size 1Ø3Ø 230V208V230V460V575V240V460V600V BMMSD-1D6-x1/10--3/43/41006525 00 BMMSD-2D5-x1/61/21/211.51006525 BMMSD-4-x1/33/43/4231006525 BMMSD-6-x1/211.5331006525 BMMSD-8-x122551006525 BMMSD-10-x1.52357.51006525 0BMMSD-13-x2337.5101006525 BMMSD-17-x33510151003010 BMMSD-22-x357.515201003010 1BMMSD-26-x37.57.515201003010 BMMSD-32-x57.51020251003010 BMMSD-40-x7.51010303010030101+ BMMS - Motor Starter with Disconnect x represents the Enclosure rating: 1 (NEMA 1) or 3 (NEMA 3R) Part Number UL HP Ratings SCIC KAIC @ Contactor NEMA Size 1Ø3Ø 230V208V230V460V575V240V460V600V BMMS-9-x12257.555500 BMMS-18-x35510155550 BMMS-32-x57.51020255551 BMMS-40-x7.5101030305552 Selection Chart BMMS - Motor Starterx represents the Enclosure rating: 1 (NEMA 1) or 3 (NEMA 3R) Part #QTYTagNema SizeHPVoltagePhaseStarter TypeEnclosure • NEMA 3R package with Disconnect: BMMSD-6-3 • NEMA 1 package with Disconnect: BMMSD-6-1 • NEMA 1 package without Disconnect: BMMS-8-1 • NEMA 3R package without Disconnect: BMMS-8-3 Example Part-NumbersProject JCI Partner Date Engineering Contractor BMMS-X-X Series Motor Starter 200-600VAC, 3-Phase, 50/60Hz input, Across the line, full-voltage non-reversing NEMA Type 1 or 3R Enclosed User Interface Hand/Off/Auto Keypad with LED mode indication Standard Control Operations Inputs Voltage Auto-RunAccepts 12-250VAC/DC. Applying voltage will send a run command to the starter when in Auto mode. Dry Contact Auto-RunNormally Open dry contact. When closed, the starter will be commanded to run when in Auto mode. Fireman’s OverrideAccepts 12-250VAC/DC. Applying voltage will cause the starter to run in all modes and all LEDs will flash. Shutdown Normally Closed dry contact. When closed, the starter will disengage the contactor and will not accept a run command (except Fireman’s Override). Hand/Off/Auto LEDs will flash. Permissive Auto Normally Closed dry contact. When closed, the starter will not accept run commands in Auto mode (except Fireman’s Override) Damper Limit Switch Normally Open dry contact. When used with the damper motor output, the contactor coil is in series with customer provided damper contacts which disable the motor starter until the damper is in position. Outputs Status Relay Normally Open relay contacts. Status Relay will close when the motor draws 60% of the FLA dial setting. Contact Ratings: 110VDC, 0.3A Resistive 125VDC, 0.5A GP 30VDC, 2.0A Resistive 120VAC 50/60Hz, 0.5A Resistive 125VAC 50/60Hz, 1.0A GP 240VAC 50/60Hz, 0.25A Resistive Fault RelayFault Relay will close in the event of a fault trip. Damper/Actuator24VDC, 1A max. Operational Overload TypeElectronic I2t trip curve Fault ResetManual (default) or Automatic Power Fail Modes Return to last mode the starter was placed in (Hand/Off/Auto) with no delay (default) Return to last mode the starter was placed in (Hand/Off/Auto) with a 10 second delay Return to Off mode (LED of last mode the starter was placed in will be flash) Environmental Ambient Operating Temp-5° to 140° F (-20° to 60° C) Ambient Storage Temp-5° to 185° F (-20° to 85° C) Relative Humidity5% to 95% non-condensing Motor ProtectionAdjustment / DescriptionDefault Setting Overload Current Setting Range1-40APer FLA Overload Trip ClassAdjustable: Class 10 or 20, Trip current = 115% of FLA settingClass 10 Cycle FaultTrip if cycle rate exceeds 20 starts/minuteAlways On StallTrips within 0.5 seconds (disabled during startup)Always On ProtectionAdjustment / DescriptionDefault Setting Current Phase Unbalance On/Off Trips within 3 sec @ 25% current unbalance. *Trip threshold changes to 80% unbalance when switched to Off On Locked Rotor Trips within 0.5 seconds Out of Calibration Trips after 10 seconds if the FLA dial setting is incorrect (set above calculated FLA range), ie. Start current is outside of an acceptable range (fla setting * 5 < inrush < fla setting * 14). Max Time to Start Regardless of FLA or I 2 t curve, always trip at start if starting current is outside of an acceptable range (inrush / 5) and still decreasing after 10 seconds. BMMS Series Motor Starter (Continued) Technical SpecificationsProject JCI Partner Date Engineering Contractor All dimensions are in inches All dimensions are in inches UL Type 1 Dimensions Starter Enclosure Dimensions UL Type 3R Dimensions BMMS Series Motor Starter (Continued)Next >