Project JCI Partner Date Engineering Contractor On/Off Disconnect Switch with Recessed Hand/Auto Modes • Concealed Hand/Auto switch discourages tampering • Lockable motor-rated On/Off switch meets safety regulations • Meets NEC motor service disconnect requirements when properly installed • LED indicator lights for power, run and fault Run Status Verification • Integrated current sensing confirms motor operational status • Quickly and accurately pinpoint malfunctioning equipment Voltage & Dry Inputs for Auto Run Command • Wire directly from the automation system to the starter, no interposing relays necessary • Save on installation costs and increase reliability. System Override Mode (Fireman’s, Occupancy or Manual) • Initiates smoke purge sequence during emergency situations for safety and code compliance or use for occupancy sensor run input (dry contact) Wide Range Class 10 Electronic Overload • Prevents ordering confusion and eliminates call backs due to mis-sized heaters • Advanced protective features including anti- cycling, manual/auto reset, etc. Standard Single Gang Box Installation • Easy to install in any location • Surface or flush mount capability High Reliability • Heavy duty motor-rated switch and control relay • No thermal elements to fail • All units include a 5-Year warranty • UL 508 Listed Overload Trip Reset • Manual or automatic overload reset in the occurance of a relay trip The BMMS-1P protects single phase motors with an adjustable class 10 electronic overload. It includes features like run status verification, a concealed Hand/Auto switch, lockable on/ off switch, and system override mode (smoke purge). All of this in a compact design that installs on a single junction box. Features 1Ø AC Input 50/60 Hz M Voltage Input Auto Run Fault Output Status Output Dry Input Auto Run Normally Open Input 12-120VAC/DC Input Selection Chart Part NumberDescription BMMS-1PStarter with Manual Overload Trip Reset BMMS-1P-ARStarter with Automatic Overload Trip Reset BMMS-1P Wiring Schematics Technical Specification BMMS-1P - Building Management Motor Starter, 1-Phase 120~230VAC, 1-Phase, 50/60Hz input, Across the line, full-voltage non-reversing (1HP) NEMA Type 1 User Interface On/Off Switch, Concealed Hand-Off-Auto Switch Standard Control Operations Inputs Voltage Auto-Run Accepts 12-120VAC/DC. Applying voltage will send a run command to the starter when in Auto mode. Dry Contact Auto-Run Normally Open dry contact. When closed, the starter will be commanded to run when in Auto mode. Outputs Status Relay Normally Open relay contacts. Status Relay will close when the motor draws 60% of the FLA dial setting. Contact Ratings: 0.3A @ 125VAC, 1A @ 24VAC Fault Relay Fault Relay will close in the event of a fault trip. Opera- tional Overload Type Electronic I2t trip curve Fault ResetManual or Automatic Power Fail Mode Return to last mode the starter was placed in (Hand/Off/Auto) with no delay (default) Environmental Ambient Operating Temp-5° to 104° F (-20° to 40° C) Ambient Storage Temp-5° to 185° F (-20° to 85° C) Relative Humidity5% to 95% non-condensing Motor ProtectionAdjustment / DescriptionDefault Setting Overload Current Setting Range 1-16APer FLA Overload Trip ClassClass 10, Trip current = 115% of FLA settingClass 10 Locked Rotor / StallTrips within 2 seconds @ 300% FLA settingAlways On BMMS-1P Series Building Management Motor Starter - Single Phase LIT-1901077Project JCI Partner Date Engineering Contractor BMMS-1P Series Motor Starter (Continued) *All dimensions displayed in inches NEMA 1 Dimensions Starter Enclosure Dimensions 1 1 1 1 1 1 1 1 1 1 1 1 Part #QTYTagHPVoltagePhaseEnclosureOverload ResetNext >