VisionPRO ® Series with RedLINK ™ Installation Guide TM TM OR OR Wired Directly to Equipment 2 Wires for Power or Battery Only (no wires) 2 Wires for Power or Battery Only (no wires) Dual Powered - C Wire or Battery (C wire or Wire Saver required to use RedLINK accessories) RedLINK to Equipment Interface Module RedLINK to TrueZONE Wireless Adapter TM 2 Current display. Underlined label signifies the current display. Mode control buttons. Use to change settings for Fan or System Heat/Cool. Menu. Select options to: set schedules, view equipment status, change IAQ settings, access installer options*, etc. Current status. Shows system mode (heat/cool), outdoor temperature and humidity (with optional outdoor sensor). Current schedule. Shows desired temperature and schedule status. Indoor conditions. Shows indoor temperature and humidity. Current Time. Alert Light. On when alert message is active or system is set to Em Heat. Flashes for battery-only power; on continuous for 24 VAC. microSD Card Port. Use card to load settings and dealer information. Reference to key features * Password is the date code. Getting started Follow these basic steps to install this thermostat, link it with the wireless accessories, and set installer options. 1 Installing the thermostat 2 Powering optional RedLINK accessories 3 Performing initial setup 4 Finding your password (Date Code) • To add or remove RedLINK accessories • To make changes to Installer Setup • To perform an Installer Test Residential/Résidentie l 1-800-468-1502 http://yourhom e. hone yw ell.co m Co mmercial/ Co mmercial e 1-888-245-1051http://custome r. hone yw ell.co m Hone yw ell, Golden Va lle y, MN 55422 RoHs Compliant Conformité RoHs Assembled in Mexico Assemblé au Mexique TH8321R1001 1 1324 Residential/Résidentiel1-800-468-1502 http://yourhome.honeywell.comCommer cial/Commer cial e 1-888-245-1051http://customer .honeywell.com Honeywell, Golden Va lley , MN 55422 RoHs Compliant Conformité RoHs Assembled in Mexico Assemblé au Mexique TH8321R1001 1 1324 Thermostat (back view) Password (Date Code) 3 NOTE: For best RedLINK performance, mount thermostats at least 2 feet apart. 1.1 Separate wallplate from thermostat. Press button on top and pull to remove the wallplate. 1.3 Connect power. 1.3a Insert supplied AA alkaline batteries for primary or backup power. NOTE: When the thermostat is NOT used with the Equipment Interface Module or the TrueZONE Wireless Adapter, a C wire is required for RedLINK. S1 S1 W Y G W2 Y2 A S1 S1 O/B Y G AUX -E Y2 L/A K RC R U1 U1 U2 U2 C CONVENTIONAL HEAT PUMP 1.3b For 24VAC primary power, connect common side of transformer to C terminal. 1.2 Mount wallplate as shown. Mount new wallplate using screws and anchors included with the thermostat. Drill 3/16-in holes for drywall. Drill 7/32-in holes for plaster. Thermostat (back view) Wallplate (back view) Wallplate Thermostat Button 1 Installing the thermostat 4 1.4 Wire the thermostat. Is the thermostat wired directly to the equipment? • If the thermostat is wired directly to the equipment: a Refer to the table and wiring diagrams on the next page. b Turn on 24VAC NOW. 24VAC (C wire) is required to connect RedLINK accessories. • If the thermostat is used with an Equipment Interface Module or TrueZONE Wireless Adapter, power the thermostat using Rc and C terminals or with batteries. NOTE: The relay outputs and inputs on the thermostat do not function when used with an Equipment Interface Module or TrueZONE Wireless Adapter. S1 S1 W Y G W2 Y2 A S1 S1 O/B Y G AUX -E Y2 L/A K RC R U1 U1 U2 U2 C CONVENTIONAL HEAT PUMP K RC R U1 U1 U2 U2 C CONVENTIONAL HEAT PUMP 1.5 Remove coin cell battery tab 1.5a Remove tab to activate coin cell battery. NOTE: Coin cell battery saves time and date during a power loss. 1.6 Mount thermostat on wallplate. Align thermostat at bottom and snap into place as shown. REMOVE DURING INST ALLA TION REMOVE DURIN G INST ALLA TION Thermostat Coin cell battery tab Wallplate 5 Terminal Designations Conventional SystemHeat Pump TerminalDescriptionTerminalDescription C Common wire from secondary side of cooling transformer (if 2 transformers). C Common wire from secondary side of cooling transformer. Rc*Cooling power. RcCooling power. R*Heating power. RHeating power. WHeat Stage 1O/BChangeover valve for heat pumps. W2Heat Stage 2AUX-EBackup Heat/Emergency Heat YCompressor Stage 1YCompressor Stage 1 Y2Compressor Stage 2Y2Compressor Stage 2 GFan RelayGFan Relay A Connect to Economizer Module or Lighting Panel (TOD). L/A Connect to Compressor Monitor, Zone Panel, Economizer Module or Lighting Panel (TOD). U1 / U1 Universal relay for humidification, dehumidification, ventilation, or a stage of heating/cooling. U1 / U1 Universal relay for humidification, dehumidification, ventilation, or a stage of heating/cooling. S1 / S1 Universal input for a wired indoor, outdoor or discharge sensor. S1 / S1 Universal input for a wired indoor, outdoor or discharge sensor. K**Connect to K on Wire Saver module. K**Connect to K on Wire Saver module. * Remove factory installed jumper for two transformer systems. ** The THP9045A1023 Wire Saver module is used on heat/cool systems when you only have four wires at the thermostat and you would like the thermostat to be powered with a common wire. Use the K terminal in place of the Y and G terminals on conventional or heat pump systems to provide control of the fan and the compressor through a single wire—the unused wire then becomes your common wire. See THP9045 instructions for more information. C K R C R U1 U1 120 VAC 24 VAC C R SYSTEM TRANSFORMER 120 VAC 24 VAC HUM, DEHUM OR VENT TRANSFORM- ER THERMOSTAT POWERED HUMIDIFIER, DEHUMIDIFIER OR VENTILATOR C K R C R U1 U1 120 VAC 24 VAC C R SYSTEM TRANSFORMER THERMOSTAT NON-POWERED HUMIDIFIER, DEHUMIDIFIER OR VENTILATOR FIELD INSTALL JUMPER BETWEEN R AND U1 CONNECTING A HEAT OR COOL STAGE TO U1DEHUMIDIFICATION WITH LOW SPEED FAN NON-POWERED HUMIDIFIER, DEHUMIDIFIER OR VENTILATORPOWERED HUMIDIFIER, DEHUMIDIFIER OR VENTILA- TOR Wire the thermostat universal relay to the low speed fan for dehumidification control at the equipment. The thermostat relay can be set to normally open or normally closed in the thermostat installer setup. 1 U1 terminals are normally open dry contacts when set up for a stage of heating or cooling. You must install a field jumper if the stage of heat- ing or cooling is powered by system transformer. Do NOT install a field jumper if the stage of heating has its own transformer. 1 2 Normally open, dry contacts Normally closed, dry contacts 1 C K R C R U1 U1 120 VAC 24 VAC C R TRANSFORMER THERMOSTAT DEHUMIDIFICATION WITH LOW SPEED FAN FIELD INSTALL JUMPER BETWEEN R AND U1 OR 2 C K R C R U1 U1 120 VAC 24 VAC C R TRANSFORMER THERMOSTAT HEAT STAGE 3, COOL STAGE 3, BACKUP HEAT STAGE 2 FOR HEAT PUMPS, OR GEOTHERMAL RADIANT HEAT 1 6 2.1 Install batteries in RedLINK accessories. • Portable Comfort Control • Wireless Outdoor Sensor* • Wireless Indoor Sensor* • Wireless Entry/Exit Remote* • Wireless Vent and Filter Boost Remote* * Requires setup. See Installer Setup options in Step 3.4. 2.2 Connect gateway to internet and connect to power. 2.2a Connect RedLINK Internet Gateway to router or modem with Ethernet cable (RJ45). 2.2b Connect gateway’s power cord to an electrical outlet that is not controlled by a wall switch. NOTE: If the thermostat is wired directly to the equipment, 24VAC (C wire) is required to connect RedLINK accessories. Turn on 24VAC before performing initial setup in Step 3. M36568 Initial setup options define the type of system you are installing: • Residential or commercial • Non-zoned or zoned • Used with or without an Equipment Interface Module (THM5421) • Used with or without the TrueZONE Wireless Adapter (THM4000) 3.1 Follow prompts on the screen to select the appropriate options. NOTE: If you are connecting the thermostat to the TrueZONE Wireless Adapter (THM4000), refer to the TrueZONE instructions to link the thermostat and RedLINK accessories. Then go to Step 3.4. 3.2 When you see the prompt Connect RedLINK Accessories? Touch No or Yes. • If you select No, continue to Step 3.4. • If you select Yes , you will be prompted to Press Connect on New Accessories. Continue to Step 3.3. 2.2a 2.2b Connect RedLINK Accessories? APPLICATION residential 2 Powering optional RedLINK accessories 3 Performing initial setup 7 3.3 Connect each RedLINK accessory. NOTE: Accessories must be at least 2 feet away from the thermostat during the linking process. 3.3a While the Press Connect message is displayed (listening mode), press and quickly release the CONNECT button on each new RedLINK accessory. 3.3b After a short delay (up to 15 seconds), check thermostat to confirm the connection of each RedLINK accessory. Touch s or t to review the list. 3.3c Touch Done at the thermostat after all new RedLINK accessories are connected. NOTE: Thermostat displays a countdown timer while in the listening mode. If it detects no activity for 15 minutes, it exits listening mode. 3.4 Finish the initial setup. Finish the setup by selecting the desired options. Touch Done after you select the last option you want to change. The thermostat now displays its Home screen and the thermostat setup is complete. THERMOSTAT TYPE programmable Outdoor Sensor has been added Press Connect on New Accessories. Listening mode 8 • To add or remove RedLINK accessories • To make changes to Installer Setup • To perform an Installer Test Finding your password You can find the date code on the back of the thermostat, or 1 Touch Menu. 2 Select Dealer Information . 3 Scroll down to see the Date Code. Linking RedLINK accessories to the thermostat 1 Touch Menu. 2 Select Installer Options. 3 Enter password (date code) and touch Done. 4 Select Wireless Manager . Wireless Manager Reset To Defaults Enter password 0 0 0 0 Installer Options TH8321R1001 Date Code: 1324 Dealer Information Installer Options 4 Finding your password (Date Code) Residential/Résidentie l 1-800-468-1502 http://yourhom e. hone yw ell.co m Co mmercial/ Co mmercial e 1-888-245-1051http://custome r. hone yw ell.co m Hone yw ell, Golden Va lle y, MN 55422 RoHs Compliant Conformité RoHs Assembled in Mexico Assemblé au Mexique TH8321R1001 1 1324 Residential/Résidentiel1-800-468-1502 http://yourhome.honeywell.comCommer cial/Commer cial e 1-888-245-1051http://customer .honeywell.com Honeywell, Golden Va lley , MN 55422 RoHs Compliant Conformité RoHs Assembled in Mexico Assemblé au Mexique TH8321R1001 1 1324 Thermostat (back view) Password (Date Code) 9 5 Select Add Device. The screen displays “Press Connect on New Accessories.” The thermostat is now in listening mode. NOTE: Accessories must be at least 2 feet away from the thermostat during the linking process. 5a Press and quickly release the CONNECT button on each new RedLINK accessory. 5b After a short delay (up to 15 seconds), check thermostat to confirm the connection of each RedLINK accessory. Touch s or t to review the list. 5c Touch Done at the thermostat after all new RedLINK accessories are connected. NOTE: Thermostat displays a count- down timer while in the listening mode. If it detects no activity for 15 minutes, it exits listening mode. Making changes to Installer Setup and performing an Installer Test NOTE: Use a microSD card to save set up time. See next page. 1 Touch Menu. 2 Select Installer Options. 3 Enter password (date code) and touch Done. 4 Select Installer Setup or Installer Test. 5 Follow prompts on the screen to select the desired setup options or to perform an equipment test. Enter password 0 0 0 0 Installer Options Installer Setup Installer Test Press Connect on New Accessories. Outdoor Sensor has been added Add Device Connected Devices Listening modeNext >