Fan ® U.S. Registered Trademark. Patents pending. Copyright © 2022 Resideo Technologies, Inc. All rights reserved. Heat Off Cool Auto On Fan Set Hold Run pm 6:30 Fan PRO TH1000E1/ TH1000DH/ TH2000DH Series Thermostats Installation Guide Read before installing This manual covers the following models • TH1100DH: For Heat only systems • TH2110DH/TH1110E1/TH1110DH: For 1 Heat/1 Cool systems • TH2210DH/TH1210DH: For 2 Heat/1 Cool heat pump systems only (Pull thermostat from wallplate and turn over to find model number.) System Types TH2110DH/TH1110DH/TH1110E1: • Gas, oil, or electric heat with air conditioning • Warm air, hot water, high-efficiency furnaces, 1 Heat/1 Cool heat pumps, steam, gravity • Heat only • Heat only with fan • Cool only • 750 mV heating systems TH2210DH/TH1210DH: • 2 Heat/1 Cool heat pumps TH1100DH: • Gas, oil, or electric heat • Warm air, hot water, steam, gravity • Heat only • 750 mV heating systems Must be installed by a trained, experienced technician Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition. Need Help? For assistance with this product please visit http://customer.resideo.com or call Resideo Customer Care toll-free at 1-800-468-1502 69-2609EFS-15Installation Guide 2 69-2609EFS—15 ENGLISH M32805 Wallplate installation Remove the wallplate from the thermo- stat as shown at left, then follow direc- tions below for mounting. 1. Pull wires through wire hole. 2. Position wallplate on wall, level and mark hole positions with pencil. 3. Drill holes at marked positions as shown below, then tap in supplied wall anchors. 4. Place wallplate over anchors, insert and tighten mounting screws. Pull at bottom to remove thermostat from wallplate. CAUTION: ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect power before beginning installation. Drill 3/16" holes for drywall. Drill 7/32" holes for plaster. MERCURY NOTICE If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact the Thermostat Recycling Corporation at www.thermostat-recycle.org or 800-238-8192 for information on how and where to properly and safely dispose of your old thermostat. M32731 TO REMOVE WALLPLATE PULL HERE Wall anchors Mounting screwsWire holePRO TH2000DH/TH1000E1/TH1000DH Series 3 69-2609EFS—15 ENGLISH Power options TH2110DH/TH1110E1/ TH1110DH: B Changeover valve energized in heating O Changeover valve energized in cooling G Fan relay Y Compressor contactor W Heat relay C 24 Vac common. For 2-transformer systems, use common wire from cooling transformer. R 24 Vac power from heating transformer Rc 24 Vac power from cooling transformer TH2210DH/TH1210DH: B Changeover valve energized in heating O Changeover valve energized in cooling G Fan relay Y Compressor contactor Aux/E Auxiliary heat relay C 24 Vac common R 24 Vac power TH1100DH: W Heat relay C 24 Vac common R 24 Vac power Terminal designations Wiring RWYGBRcOC TH2110DH/TH1110E1/ TH1110DH: CYGOBRAux/ E TH2210DH/TH1210DH Not Used M32806 WC KEEP WIRES IN THIS SHADED AREA REMOVE FACOTRY- INSTALLED JUMPER ONLY FOR TWO- TRANSFORMER SYSTEMS CONNECT C FOR PRIMARY AC POWER (OPTIONAL IF BATTERIES ARE INSTALLED) TH2110DH TERMINAL BLOCK SHOWN XXXX M32807 INSERT BATTERIES FOR PRIMARY OR BACKUP POWER RWC TH1100DH Not UsedInstallation Guide 4 69-2609EFS—15 ENGLISH Wiring 2H/1C Heat Pump System TH2210DH/TH1210DH B Changeover valve energized in heating [5] O Changeover valve energized in cooling [5] G Fan relay Y Compressor contactor Aux/E Auxiliary heat relay C 24 Vac common [3] R Power [1] 1H/1C System TH2110DH/TH1110E1/ TH1110DH (1 transformer) G Fan relay Y Compressor contactor W Heat relay C 24 Vac common [3] R [R+Rc joined by jumper] Rc Power [1] 1H/1C System TH2110DH/ TH1110E1/ TH1110DH (2 transformers) G Fan relay Y Compressor contactor W Heat relay C 24 Vac common [3, 4] R Power (heating transformer) [1, 2] Rc Power (cooling transformer) [1, 2] Heat Only System TH1100DH W Heat relay C 24Vac common [3] R Power [1] 1H/1C Heat Pump System TH2110DH/ TH1110E1/TH1110DH [7] B Changeover valve energized in heating [5] O Changeover valve energized in cooling [5] G Fan relay Y Compressor contactor [6] W [W+Y joined by jumper] C 24 Vac common [3] R [R+Rc joined by jumper] Rc Power [1] Heat Only System TH2110DH/TH1110E1/TH1110DH W Heat relay C 24Vac common [3] R [R+Rc joined by jumper] Rc Power [1] Heat Only System with Fan TH2110DH/TH1110E1/TH1110DH G Fan relay W Heat relay C 24 Vac common [3] R [R+Rc joined by jumper] Rc Power [1] Cool Only System TH2110DH/TH1110E1/TH1110DH G Fan relay Y Compressor contactor C 24 Vac common [3] R [R+Rc joined by jumper] Rc Power [1] NOTES Wire specifications: Use 18- to 22-gauge thermostat wire. Shielded cable is not required. [1] Power supply. Provide disconnect means and overload protection as required. [2] Remove jumper for 2-transformer sys- tems. [3] Optional 24 Vac common connection. [4] Common connection must come from cooling transformer. [5] Use either O or B terminals for changeover valve. [6] Use a small piece of wire (not supplied) to connect W and Y terminals. [7] Set fan operation switch to Heat Pump (see page 5). Wiring guide — conventional and heat pump systems CYGOBRAux/ E Not Used RcCYWGR RcCYWGR RcCYWGOBR RcCWR RcCWGR RcCYGR See [notes] below RWC Not UsedPRO TH2000DH/TH1000E1/TH1000DH Series 5 69-2609EFS—15 ENGLISH W/ Aux Not Used Heat Off CoolAuto On Fan M32705 W/ Aux Not Used M32757 Heat Off CoolAuto On Fan TH2110DH/TH1110E1/ TH1110DH only: • Gas or Oil: For gas or oil heating systems, leave the fan operation switch in this factory-set position. (This setting is for systems that control the fan in a call for heat.) • Electric or Heat Pump: Change the switch to this setting for heat pump or electric heat systems. (This setting is for systems that allow the thermostat to control the fan in a call for heat, if a fan wire is connected to the G terminal.) Align the 2 tabs at the top of the wall- plate with corresponding slots on the back of the thermostat, then push gently until the thermostat snaps in place. Thermostat mounting Set fan operation switch. Push excess wire back into the wall opening. Plug wall opening with non-flammable insulation. Fan operation settings XXXX M32818 GAS OR OIL ELECTRIC OR HEAT PUMP GAS OR OIL ELECTRIC OR HEAT PUMP Settings are the same on TH1110E1 & TH1110DH models. TH1110E1 has a larger display.Installation Guide 6 69-2609EFS—15 ENGLISH 5 5 M32819 Follow the procedure below to configure the thermostat to match the installed heating/cooling system, and customize feature operation as desired. Function number Setting To begin, press and hold the s and t buttons until the display changes. Press the s or t button to change the setting. Press the s and t buttons simultaneously for one second to advance to the next function. Press and hold the s and t buttons to exit and save settings. Installer setup M32713 Heat Off CoolAuto On Fan M32758 Heat Off CoolAuto On Fan NOTE: If you do not press any button for 60 seconds while you are in the setup menu, the thermostat automatically saves any changes made and exits the menu. TH2000DH seriesTH1000E1, TH1000DH series (TH1000E1 has a larger display)PRO TH2000DH/TH1000E1/TH1000DH Series 7 69-2609EFS—15 ENGLISH Setup function Settings & options (factory default in bold) 5 Heating cycle rate (CPH: cycles/hour) TH2110DH, TH1110E1, TH1110DH and TH1100DH 5 For gas or oil furnaces of less than 90% efficiency 1 For steam or gravity systems 3 For hot water systems & furnaces of over 90% efficien- cy 6 For electric furnaces [Other cycle rate options: 2 or 4 CPH] 6 Auxiliary heat cycle rate (CPH) TH2210DH and TH1210DH 5 For gas or oil furnaces of less than 90% efficiency 1 For steam or gravity systems 3 For hot water systems & furnaces of over 90% efficiency 6 For electric furnaces [Other cycle rate options: 2 or 4 CPH] 9 Compressor cycle rate (CPH) 3 Recommended for most compressors [Other cycle rate options: 1, 2, 4, 5, or 6 CPH] 13 Early Start (TH2110DH and TH2210DH) 1 On **See page 8 0 Off 14 Temperature display 0 Fahrenheit 1 Celsius 15 Compressor protection 1 Five-minute compressor off time (See page 8) 0 No compressor off time 20 Clock display (TH2110DH and TH2210DH) 0 12-hour display 1 24-hour display 25 Lower temperature range (TH1100DH only) 0 Standard range 40°F to 90°F (4.5°C to 32°C) 1 Lower range (for garage mode) 35°F to 90°F (1.5°C to 32°C) 40 Restore program schedule to default (TH2110DH and TH2210DH) 0 Off 1 On - program schedule default settings are listed in the operating manual Installer setup CAUTION: EQUIPMENT DAMAGE HAZARD Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly.Installation Guide Resideo Technologies Inc. 1985 Douglas Drive North, Golden Valley, MN 55422 1-800-468-1502 69-2609EFS—15 M.S. Rev. 05-22 | Printed in United States www.resideo.com © 2022 Resideo Technologies, Inc. All rights reserved. The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates. Tous droits réservés. La marque de commerce Honeywell Home est utilisée avec l’autorisation d’Honeywell International, Inc. Ce produit est fabriqué par Resideo Technologies, Inc. et ses sociétés affiliées. Todos los derechos reservados. La marca comercial Honeywell Home se utiliza bajo licencia de Honeywell International, Inc. Este producto es fabricado por Resideo Technologies, Inc. y sus afiliados. Early Start (Setup Function 13): Early start allows the heating or cooling to turn on before the program start time, so the temperature is reached at the time you set. Compressor Protection (Setup Function 15): Forces the compressor to wait a few minutes before restarting, to prevent damage. During the wait time, the message Cool On (or Heat On for TH2210DH & TH1210DH) will flash on the display. Please contact your distributor to order replacement parts. Cover plate assembly* ............................................... Part Number 50002883-001 *Use to cover marks left by old thermostats. Temperature Ranges • Cool: 50° to 99°F (10° to 37°C) • Heat: 40° to 90°F (4.5° to 32°C)* *TH1100DH heat can be set to 35°F to 90°F (1.5°C to 32°C) Operating Ambient Temperature • 32° to 120°F (0° to 48.9°C) Shipping Temperature • -20° to 120°F (-28.9° to 48.9°C) Operating Relative Humidity • 5% to 90% (non-condensing) Physical Dimensions • 3-7/16”H x 4-10/16”W x 1-3/16”D 87mm H x 119mm W x 30mm D Electrical Ratings Voltage Running System (50/60Hz) Current Heat (1st stage) 20-30 Vac 0.02-1.0 A (Powerpile) 750 mV DC 100 mA DC Auxiliary heat 20-30 Vac 0.02-1.0 A Cooling 20-30 Vac 0.02-1.0 A The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The correct disposal of end-of-life equipment will help prevent potential negative consequences for the environment and human health. Accessories & replacement parts Special functions SpecificationsSérie PRO TH1000E1/ TH1000DH/ TH2000DH Thermostats Guide d’installation ® Marque déposée aux É.-U. Brevets en instance. © 2022 Resideo Technologies, Inc. Tous droits réservés. Lire avant l’installation Heat Off Cool Auto On Fan Set Hold Run pm 6:30 Fan Fan Besoin d’aide? Pour obtenir de l’assistance au sujet de ce produit, consulter le http://customer.resideo.com ou téléphoner sans frais au Centre de service à la clientèle de Resideo au 1 800 468-1502 Doit être installé par un technicien d’expérience ayant reçu la formation pertinente. Lire attentivement les instructions. Le fait de ne pas les suivre risque d’endommager le produit ou de constituer un danger. Le présent guide porte sur les modèles suivants : • TH1100DH: Pour systèmes de chauffage seulement • TH2110DH/TH1110E1/TH1110DH : Pour systèmes à 1 étage de chauffage/1 étage de refroidissement • TH2210DH/TH1210DH : Pour thermopompes à 2 étages de chauffage/1 étage de refroidissement seulement (Retirer le thermostat de la plaque murale et le retourner pour trouver le numéro de modèle.) Types de système TH2110DH/TH1110DH/TH1110E1 : • Gaz, mazout ou chauffage électrique avec climatisation • Air chaud, eau chaude, appareils de chauffage à haut rendement, thermopompes à 1 étage de chauffage/1 étage de refroidissement, vapeur et gravité • Chauffage seulement • Chauffage seulement avec ventilateur • Refroidissement seulement • Systèmes de chauffage 750 mV TH2210DH/TH1210DH : • Thermopompes à 2 étages de chauffage/1 étage de refroidissement TH1100DH: • Gaz, mazout ou chauffage électrique • Air chaud, eau chaude, vapeur et gravité • Chauffage seulement • Systèmes de chauffage 750 mVNext >