Installation Instructions Non-Programmable Digital Thermostat PRO 3000 Series TH3110D1008 TH3210D1004 Wallplate installation M29389A Remove the wallplate from the thermostat by pulling from the bottom, then follow directions below for mounting. 1. Pull wires through wire hole. 2. Position wallplate on wall, level and mark hole positions with pencil. 3. Drill holes at marked positions as shown below, then tap in supplied wall anchors. 4. Place wallplate over anchors, insert and tighten mounting screws. UP MCR29390A Drill 3/16” holes for drywall. Wire hole Read before installing Mounting screws Drill 7/32” holes for plaster.2 Power options TH3110D C 24 Vac common. For 2 transformer systems, use common wire from cooling transformer. B Changeover valve energized in heating R 24 Vac power from heating transformer Rc 24 Vac power from cooling transformer O Changeover valve energized in cooling G Fan relay Y Compressor contactor W Heat relay TH3210D C 24 Vac common B Changeover valve energized in heating R 24 Vac power L Sends output when set to Em. Heat O Changeover valve energized in cooling G Fan relay Y Compressor contactor Aux Auxiliary heat relay E Emergency heat relay Wiring terminal designations MCR29391A TH3110D Terminal block shown Connect C for primary AC power (optional if batteries are installed). Keep wires in this shaded area Insert batteries for primary or backup power Remove factory- installed jumper only for two-transformer systems. CROGYEBAuxL CROGYWBRc3 1H/1C Heat Pump System TH3110D [7] C 24 Vac common [3] B Changeover valve energized in heating [5] R [R+Rc joined by jumper] Rc Power [1] O Changeover valve energized in cooling [5] G Fan relay Y Compressor contactor [6] W [W+Y joined by jumper] Heat Only System TH3110D C 24 Vac common [3] R [R+Rc joined by jumper] Rc Power [1] W Heat relay Heat Only System with Fan TH3110D C 24 Vac common [3] R [R+Rc joined by jumper] Rc Power [1] G Fan relay W Heat relay Cool Only System TH3110D C 24 Vac common [3] R [R+Rc joined by jumper] Rc Power [1] G Fan relay Y Compressor contactor 2H/1C Heat Pump System TH3210D C 24 Vac common [3] B Changeover valve energized in heating [5] R Power [1] L Sends output when set to Em. Heat [8] O Changeover valve energized in cooling [5] G Fan relay Y Compressor contactor Aux Auxiliary heat relay [9] E Emergency heat relay [9] 1H/1C System TH3110D (1 transformer) C 24 Vac common [3] R [R+Rc joined by jumper] Rc Power [1] G Fan relay Y Compressor contactor W Heat relay 1H/1C System TH3110D (2 transformers) C 24 Vac common [3, 4] R Power (heating transformer) [1, 2] Rc Power (cooling transformer) [1, 2] G Fan relay Y Compressor contactor W Heat relay Wiring conventional and heat pump systems NOTES Wire specifications: Use 18- to 22-gauge thermostat wire. Shielded cable is not required. [1] Power supply. Provide disconnect means and overload protection as required. [2] Remove jumper for 2-transformer sys- tems. [3] Optional 24 Vac common connection. [4] Common connection must come from cooling transformer. [5] Use either O or B terminals for change- over valve. [6] Use a small piece of wire (not supplied) to connect W and Y terminals. [7] Set fan operation switch to Heat Pump (see page 5) and configure system type for heat pump (see page 6). [8] L terminal sends a continuous output when thermostat is set to Em. Heat. Connect to Honeywell Home zoning pan- els to switch the panel to Emergency Heat. [9] Install field jumper between Aux and E if there is no emergency heat relay. CROGY E BAuxL CROGYWBRc CROGYWBRc CROGYWBRc CROWBRc CROGWBRc CROGYBRc4 MCR29401A UP MCR29400A Thermostat mounting Set fan operation switch. Fan operation settings (TH3110D only) 1. Align the 4 tabs on the wallplate with corresponding slots on the back of the thermostat. 2. Push gently until the thermostat snaps in place. 3. Push excess wire back into the wall opening. 4. Plug wall opening with non- flammable insulation. Gas or Oil: For gas or oil heating systems, leave the fan operation switch in this factory-set position. (This setting is for systems that control the fan in a call for heat.) Electric or Heat Pump: Change the switch to this setting for heat pump or electric heat systems. (This setting is for systems that allow the thermostat to control the fan in a call for heat, if a fan wire is connected to the G terminal.)5 Setup 1 0 Setup function Settings & options (factory settings in bold) 1 System type TH3110D only 0 Gas, oil or electric heat with air conditioning 1 Heat pump (5 minute compressor off time in heating and cooling) 5 Heating cycle rate (CPH: cycles/hour) TH3110D only 5 For gas or oil furnaces of less than 90% efficiency 1 For steam or gravity systems 3 For hot water systems & furnaces of over 90% efficiency 9 For electric furnaces [Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH] 6 Auxiliary heat cycle rate (CPH) TH3210D only 5 For gas or oil furnaces of less than 90% efficiency 1 For steam or gravity systems 3 For hot water systems & furnaces of over 90% efficiency 9 For electric furnaces [Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH] 8 Emergency heat cycle rate (CPH) TH3210D only 9 For electric emergency heat 1 For steam or gravity systems 3 For hot water systems & furnaces of over 90% efficiency 5 For gas or oil furnaces of less than 90% efficiency [Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH] 9 Compressor cycle rate (CPH) 3 Recommended for most compressors [Other cycle rate options: 1, 2, 4, 5, or 6 CPH] 14 Temperature display 0 Fahrenheit 1 Celsius 15 Compressor protection 5 Five-minute compressor off time [Other options: 0, 1, 2, 3 or 4-minute off time] Compressor Protection (Setup Function 15): Forces the compressor to wait a few minutes before restarting, to prevent damage. During the wait time, the message Cool On or Heat On (heat pumps only) will flash on the display. Follow the procedure below to configure the thermostat to match the installed heating/cooling system, and customize feature operation as desired. To begin, press and hold the s and t buttons until the display changes. • Press t to change settings. • Press s to advance to next function. • Press and hold ts to exit and save settings. Installer Setup Function number Setting6 10 Heating system0 Heat and fan turn off. 1 Heat turns on. 2 Auxiliary heat turns on (TH3210D only). 20 Emergency heat 0 Heat and fan turn off. 1 Heat and fan turn on. 2 Auxiliary heat turns on. 30 Cooling system0 Compressor and fan turn off. 1 Compressor and fan turn on. 70 Thermostat information (for reference only) 71 Software revision number (major revisions) 72 Software revision number (minor revisions) 73 Configuration identification code (major) 74 Configuration identification code (minor) 75 Production configuration date code (week) 76 Production configuration date code (year) System test System status } (TH3210D only) Installer system test 1. Set SYSTEM switch to Heat. 2. Press t to turn on and check systems (see table, below). 3. Press t until systems turn off. 4. Set SYSTEM switch to Em Heat and repeat steps 2-3 above (TH3210D only). 5. Set SYSTEM switch to Cool and repeat steps 2-3 above. 6. Press and hold ts to terminate test at any time. System switch 10 0 Test System test number System status7 Troubleshooting If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily. Display is blank • Check circuit breaker and reset if necessary. • Make sure power switch at heating & cooling system is on. • Make sure furnace door is closed securely. • Make sure fresh AA alkaline batteries are correctly installed (see page 2). Heating or cooling system does not respond • Set system switch to Heat. Make sure the temperature is set higher than the Inside temperature. • Set system switch to Cool. Make sure the temperature is set lower than the Inside temperature. • Wait 5 minutes for the system to respond. Temperature settings do not change Make sure heating and cooling temperatures are set to acceptable ranges: • Heat: 40° to 90°F (4.5° to 32°C). • Cool: 50° to 99°F (10° to 37°C). “Cool On” or “Heat On” is flashing • Compressor protection feature is engaged. Wait 5 minutes for the system to restart safely, without damage to the compressor. “Heat On” is not displayed • Set the System switch to Heat, and set the temperature level above the current room temperature. “Cool On” is not displayed • Set the System switch to Cool, and set the temperature level below the current room temperature. Temperature Ranges Heat: 40° to 90°F (4.5° to 32°C) Cool: 50° to 99°F (10° to 37°C) Operating Ambient Temperature 32° to 120°F (0° to 48.9°C) Shipping Temperature -20° to 120°F (-28.9° to 48.9°C) Operating Relative Humidity 5% to 90% (non-condensing) Physical Dimensions 3-13/16” H x 5-3/8” W x 1-1/4” D 97 mm H x 137 mm W x 32 mm D Input: 24 V~ @ 60 Hz, 1.0 A Electrical Ratings System Voltage (50/60Hz) Running Current Heat (1st stage) 20-30 Vac 0.02-1.0 A (Powerpile) 750 mV DC 100 mA DC Emergency heat 20-30 Vac 0.02-1.0 A Auxiliary heat 20-30 Vac 0.02-1.0 A Cooling 20-30 Vac 0.02-1.0 A SpecificationsResideo Inc., 1985 Douglas Drive North Golden Valley, MN 55422 www.resideo.com 69-1929EFS—07 M.S. Rev. 08-20 | Printed in United States © 2020 Resideo Technologies, Inc. All rights reserved. The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates. Tous droits réservés. La marque de commerce Honeywell Home est utilisée avec l’autorisation d’Honeywell International, Inc. Ce produit est fabriqué par Resideo Technologies, Inc. et ses sociétés affiliées. Todos los derechos reservados. La marca comercial Honeywell Home se utiliza bajo licencia de Honeywell International, Inc. Este producto es fabricado por Resideo Technologies, Inc. y sus afiliados. 69-1929EFS-07 M29423B LEVEL HERELEVEL HERE UP M29421A For assistance with this product, please visit customer.resideo.com . Or call Customer Care toll-free at 1-800-468-1502. Need Help? Turn thermostat over to find model number and date code. Pull at bottom to remove thermostat from wallplate. CAUTION: EQUIPMENT DAMAGE HAZARD Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly. CAUTION: ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect power before beginning installation. CAUTION: MERCURY NOTICE If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal. https://customer.resideo.com/en-US/support/residential/codes-and-standards/ FCC15105/Pages/default.aspx CAUTION: ELECTRONIC WASTE NOTICE The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The correct disposal of end-of-life equipment will help prevent potential negative consequences for the environment and human health.PRO 3000 Série TH3110D1008 TH3210D1004 Notice D’installation Thermostat numérique non programmable M29389A Installation de la plaque murale Séparer la plaque murale du thermostat comme l’indique l’illustration ci-contre, puis suivre les directives d’installation. 1. Faire passer les fils par l’ouverture réservée aux fils. 2. Placer la plaque murale sur le mur, mettre de niveau et marquer au crayon l’emplacement des trous. 3. Percer les trous aux endroits marqués à l’aide d’une perceuse, puis insérer les chevilles d’ancrage fournies. 4. Apposer la plaque murale sur les chevilles, insérer puis resserrer les vis de fixation. UP MCR29390A Trou du filVis de montage Utiliser une mèche de 3/16 po si le mur est en placoplâtre Utiliser une mèche de 7/32 po si le mur est en plâtre. Lire avant l’installationNext >