High Performance InverterNew24A1-E-0042fThe FRENIC-Ace Inverters are full feature drives offering great value and maintain high performance through optimal design for a wide range of applications for various machines and devices.FUJI ELECTRIC INVERTERSEnjoy A Full Range Of ApplicationsThe standard inverter for the next generation, the FRENIC-Ace, can be used in most types of application—from fans and pumps to specialized machinery.Introducing Our New Standard Inverter!ItdiONStddIt!The Next Generation Of Inverters Have Arrived*HP@ 60Hz 3PH230V 3PH460V.Nominalappliedmotor[kW(HP*)]0.1(1/8)0.2(1/4)0.4(1/2)0.75(1)1.1(1.5)1.5(2)2.2(3)3(4)3.7(5)5.5(7.5)7.5(10)11(15)15(20)18.5(25)22(30)30(40)37(50)45(60)55(75)75(100)90(125)110(150)132(200)160(250)200(300)220(350)250(400)280(450)315(500)FRN0002E2 -4FRN0004E2 -4FRN0006E2 -4FRN0007E2 -4FRN0012E2 -4FRN0022E2 -4FRN0029E2 -4FRN0037E2 -4FRN0044E2 -4FRN0059E2 -4FRN0072E2 -4FRN0085E2 -4FRN0105E2 -4FRN0139E2 -4FRN0168E2 -4FRN0203E2 -4FRN0240E2 -4FRN0290E2 -4FRN0361E2 -4FRN0415E2 -4FRN0520E2 -4FRN0590E2 -42.1A4.1A5.5A6.9A12A21.5A28.5A37A44A59A72A85A105A139A168A203A240A290A361A415A520A590AFRN0002E2 -4FRN0004E2 -4FRN0006E2 -4FRN0007E2 -4FRN0012E2 -4FRN0022E2 -4FRN0029E2 -4FRN0037E2 -4FRN0044E2 -4FRN0059E2 -4FRN0072E2 -4FRN0085E2 -4FRN0105E2 -4FRN0139E2 -4FRN0168E2 -4FRN0203E2 -4FRN0240E2 -4FRN0290E2 -4FRN0361E2 -4FRN0415E2 -4FRN0520E2 -4FRN0590E2 -41.8A3.4A5A6.3A11.1A17.5A23A31A38A45A60A75A91A112A150A176A210A253A304A377A415A477AFRN0002E2 -4FRN0004E2 -4FRN0006E2 -4FRN0007E2 -4FRN0012E2 -4FRN0022E2 -4FRN0029E2 -4FRN0037E2 -4FRN0044E2 -4FRN0059E2 -4FRN0072E2 -4FRN0085E2 -4FRN0105E2 -4FRN0139E2 -4FRN0168E2 -4FRN0203E2 -4FRN0240E2 -4FRN0290E2 -4FRN0361E2 -4FRN0415E2 -4FRN0520E2 -4FRN0590E2 -41.8A3.4A5A6.3A11.1A17.5A23A31A38A45A60A75A91A112A150A176A210A253A304A377A415A520ARatingconditionApplicationOverload current rating150% -1min,200% -0.5secMax. ambient temp.50˚COverload current rating120% -1minMax. ambient temp.50˚COverload current rating150% -1min,200% -0.5secMax. ambient temp.50˚COverload current rating120% -1minMax. ambient temp.50˚COverload current rating150% -1minMax. ambient temp.40˚COverload current rating120% -1minMax. ambient temp.40˚CFRN0002E2 -4FRN0004E2 -4FRN0006E2 -4FRN0007E2 -4FRN0012E2 -4FRN0022E2 -4FRN0029E2 -4FRN0037E2 -4FRN0044E2 -4FRN0059E2 -4FRN0072E2 -4FRN0085E2 -4FRN0105E2 -4FRN0139E2 -4FRN0168E2 -4FRN0203E2 -4FRN0240E2 -4FRN0290E2 -4FRN0361E2 -4FRN0415E2 -4FRN0520E2 -4FRN0590E2 -41.5A2.5A4.2A5.5A9A13A18A24A30A39A45A60A75A91A112A150A176A210A253A304A377A415AFRN0001E2 -2FRN0002E2 -2FRN0004E2 -2FRN0006E2 -2FRN0010E2 -2FRN0012E2 -2FRN0020E2 -2FRN0030E2S-2FRN0040E2S-2FRN0056E2S-2FRN0069E2S-2FRN0088E2S-2FRN0115E2S-21.3A2A3.5A6A9.6A12A19.6A30A40A56A69A88A115AFRN0001E2 -2FRN0002E2 -2FRN0004E2 -2FRN0006E2 -2FRN0010E2 -2FRN0012E2 -2FRN0020E2 -2FRN0030E2S-2FRN0040E2S-2FRN0056E2S-2FRN0069E2S-2FRN0088E2S-2FRN0115E2S-20.8A1.6A3A5A8A11A17.5A25A33A47A60A76A90AND ratingModelRatedoutputcurrentHD ratingModelRatedoutputcurrentHND ratingModelRatedoutputcurrentHHD ratingModelRatedoutputcurrentHND ratingModelRatedoutputcurrentHHD ratingModelRatedoutputcurrent3-phase 400V(460V) series3-phase 200V(230V) series1-phase 200V seriesFans, pumpsWire drawingVertical conveyanceFans, pumpsWire drawingVertical conveyanceWinding machinesPrinting machinesFans, pumpsWire drawingVertical conveyanceWinding machinesPrinting machinesVertical conveyanceWinding machinesPrinting machinesOverload current rating150% -1min,200% -0.5secMax. ambient temp.50˚CFRN0001E2 -7FRN0002E2 -7FRN0003E2 -7FRN0005E2 -7FRN0008E2 -7FRN0011E2 -70.8A1.6A3A5A8A11AHHD ratingModelRatedoutputcurrent2Major FunctionsCommon SpecificationsBasic Wiring DiagramTerminal FunctionsExternal DimensionsOptionsStandard Model SpecificationsOption CategoryMounting adapter for option cardOption NameRS-485 communications cardPG interface (5V) cardPG interface (12/15V) cardDeviceNet communication cardCC-Link communication cardPROFIBUS-DP communication cardEtherNet/IP communication cardProfiNet-RT communication cardCANopen communication cardDigital Input / Output interface cardAnalog Output interface interface cardThe adapter is mounted on the front side of the inverter.(OPC-E2-ADP1)0002 to 0044 (400V),0001 to 0069 (200V)0059 to 0072 (400V),0069 to 0115 (200V)more than 0085 (400V)The adapter is mounted inside of the inverter.(OPC-E2-ADP2)UnnecessaryThe adapter is mounted inside of the inverter.(OPC-E2-ADP3)Terminal blockCommunication *1Input / Output interface *1Customizable logic function is available as a standard feature. FRENIC-Ace has built-in customizable logic functions with a maximum of 200 steps including both digital and analog operation functions, giving customers the ability to customize their inverters—from simple logic functions to full-scale programming. Fuji Electric also has plans to offer programming templates for wire drawing machines, hoists, spinning machines, and other applications so that the FRENIC-Ace can be used as a dedicated purpose inverter.FRENIC-Ace has readily available interface cards and various types of fieldbus / network to maximize its flexibility.Wide Variety Of Functions As A Standard FeatureSuperior FlexibilityCustomizable LogicExample: Hoist crane applicationProgramming the FRENIC-Ace main unit with the required logic for controlling a hoist(1) Set speed program(2) Reset the alarm by using the push-button switch(3) Mechanical limit switch function(4) Detect load(5) Automatic speed drive when no load is detected(6) Overload stop functionDedicated/specialized functions forhoist application implemented byusing customizable logicSensorless dynamic torque vector controlMotor vector control with PG (with optional card)Synchronous motor with sensorless vector control 2-channel on-board RS485 communications port Standard CANopen compatibilityRemovable keypad deviceRemovable control terminal block board*1 Available by the combination use of the mounting adapter.FUJI ELECTRIC INVERTERS3StandardsGlobal ComplianceStandard compliance with European regulations that limit the use of specific hazardous substances (RoHS)<Six hazardous substances>Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), polybrominated biphenyl ether (PBDE)<About RoHS>Directive 2002/95/EC, issued by the European Parliament and European Council, limits the use of specific hazardous substances in electrical and electronic devices.LAN cableUSB–USBminiB cableEN ISO 13849-1: 2008, Cat.3 / PL=eIEC/EN 60204-1: 2005/2006 Stop category 0IEC/EN 61508-1 to -7: 2010 SIL3IEC/EN 61800-5-2: 2007 SIL3 (Safety feature: STO)IEC/EN 62061: 2005 SIL3Multi-Function Keypad (option)FRENIC-Ace is equipped with STO functional safety function as a standard. Therefore output circuit magnetic contactors are not required for safe stop implementation. Enhanced standard features position FRENIC-Ace ahead of its class (Safety input: 2CH, output: 1CH).Functional SafetyFRENIC-Ace components have a design life of ten years.A longer maintenance cycle also helps to reduce running costs.10 Years Lifetime DesignMulti-function keypadwith LCD screenKeypad with USB port *1 ND specifications have a rated current of two sizes higher than HHD specifications, so the life is 7 years.*2 The designed lives are the calculated values and not the guaranted ones.Design life *2Main circuit capacitorElectrolytic capacitors on PCB Cooling fanLife conditionsAmbient temperatureLoad rate10 years *110 years *110 years *1+40°C (104°F)100% (HHD specifications)80% (HND/HD/ND specifications)RoHS DirectiveStandard complianceUL Standard (cUL Certified)Complies with (coming soon)FRENIC-Ace has two different multi-function keypads available Multi-function keypad with LCD display: Enhanced HMI functionality Keypad with USB port : Connect to a computer for more efficient operation (set-up, troubleshooting, maintenance, etc)KC* EC Directives (CE Mark)* Only FRN E2 - G 4Major FunctionsCommon SpecificationsBasic Wiring DiagramTerminal FunctionsExternal DimensionsOptionsStandard Model SpecificationsNDHDHNDHHDNDHDHNDHHDNDHDHNDHHDND, HNDHDHHDNDHDHNDHHDNDHDHNDHHDNDHDHNDHHDNDHDHNDHHDNDHND, HDHHDTypeNominal applied motor *1 [kW(HP)]Rated capacity [kVA] *2Rated voltage [V] *3Three-phase 380 to 480V (With AVR) 120% of nominal current for 1min150% of nominal current for 1min150% of nominal current for 1min or 200% of nominal current for 0.5sThree-phase 380 to 480V (With AVR)Voltage: +10 to -15% (Voltage unbalance:2% or less *8, Frequency: +5 to -5%)Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% (ND spec.), 0 to 80% (HD/HND spec.), 0 to 100% (HHD spec.) of nominal currentBuilt-inOptionOptionOptionOptionIP20, UL open typeNatural coolingOverload capabilityMain power supplyRated current without DCR *5 [A] Rated current with DCR *5 [A] Required power supply capacity *6 [kVA]Braking torque *7 [%]Braking chopperMinimum connectable resistance[ohm]Braking resistorDC braking DC reactor (DCR)Enclosure (IEC60529)Cooling methodMass [kg]Voltage/frequency variationsRated current [A] *4SpecificationsItemsStandard Model SpecificationsThree phase 400V class seriesOutput ratingsInput ratingsBrakingFan cooling100%40%FRN E2S-4GA,FRN E2S-4GBFRN E2S-4E,FRN E2S-4GBFRN E2S-4GB*1 Fuji 4-pole standard motor. At the selection of the inverter rating, consider not only the rating capacity(kW) is enough but also inverter output current is larger than selected the motor's nominal current.*2 Rated capacity is calculated by assuming the output rated voltage as 440 V.*3 The output voltage cannot exceed the power supply voltage.*4 When the carrier frequency (F26) is set to below value or higher, the inverter is sure to be necessary to derate their nominal current. HHD spec.---type 0002 to 0012 : 8kHz, type 0022 to 0168 : 10kHz, type 0203 to 0590 : 6kHz HND spec.---type 0002 to 0012 : 8kHz, type 0022 to 0059 : 10kHz, type 0072 to 0168 : 6kHz, type 0203 to 0590 : 4kHz HD,ND spec.---All type : 4kHz The rated output current at HD/ND spec. is decreased 2% for every 1 °C (1.8 °F) when ambient temperature is +40 °C (+104 °F) or more. *5 The value is calculated assuming that the inverter is connected with a power supply with the capacity of 500 kVA (or 10 times the inverter capacity if the inverter capacity exceeds 50 kVA) and %X is 5%. Be sure to use the DCR when applicable motor capacity is 75kW or above. *6 Obtained when a DC reactor (DCR) is used.*7 Average braking torque for the motor running alone. (It varies with the efficiency of the motor.)*8 Voltage unbalance (%) =(Max. voltage (V) - Min. voltage (V))/Three -phase average voltage (V) × 67 (IEC 61800 - 3) If this value is 2 to 3%, use an optional AC reactor (ACR).*10 HND spec. of the type 0007 and 0012: allowable ambient temperature 40 °C (+104 °F) or less. The rated output current at HND spec. is decreased 1% for every 1 °C (1.8 °F) when ambient temperature is +40 °C (+104 °F) or more.002915(20)11(15)11(15)7.5(10)2218181428.523.023.018.043.833.033.023.228.821.121.114.420151510605.0002211(15)7.5(10)7.5(10)5.5(7.5)1613139.921.517.517.513.033.023.223.217.321.114.414.410.61510107.312%15%15%20%805.000020.75(1)0.75(1)0.75(1)0.4(1/2)1.61.41.41.12.11.81.81.52.72.72.71.71.51.51.50.851.11.11.10.653%53%53%2001.200041.5(2)1.1(1.5)1.1(1.5)0.75(1)3.12.62.61.94.13.43.42.54.83.93.93.12.92.12.11.62.11.51.51.250%68%68%1.500062.2(3)2.2(3)2.2(3)1.5(2)4.23.83.83.25.55.05.04.27.37.37.35.94.24.24.23.03.03.03.02.148%48%48%70%1.500073.0(4)3.0(4)3.0(4)*102.2(3)5.34.84.8*104.26.96.36.3*105.511.311.311.3*108.25.85.85.8*104.44.14.14.1*103.129%29%29%*101.600125.5(7.5)5.5(7.5)5.5(7.5)*103.7(5)9.18.58.5*106.91211.111.1*109.016.816.816.8*1013.010.110.110.1*107.37.07.07.0*105.127%27%27%*101301.9003718.5(25)15(20)15(20)11(15)2824241837.031.031.024.052.343.843.833.035.528.828.821.125202015408.0004422(30)18.5(25)18.5(25)15(20)3429292344.038.038.030.060.652.352.343.842.235.535.528.82925252034.49.0005930(40)22(30)22(30)18.5(25)4534343059.045.045.039.077.960.660.652.357.042.242.235.5392929259.5007237(50)30(40)30(40)22(30)5546463472.060.060.045.094.377.977.960.668.557.057.042.2473939291016016FUJI ELECTRIC INVERTERS5NDHDHNDHHDNDHDHNDHHDNDHDHNDHHDND, HNDHDHHDNDHDHNDHHDNDHDHNDHHDNDHDHNDHHDNDHDHNDHHDNDHND, HDHHDNominal applied motor *1 [kW(HP)]Rated capacity [kVA] *2Rated voltage [V] *3Three-phase 380 to 480V (With AVR) 120% of nominal current for 1min150% of nominal current for 1min150% of nominal current for 1min or 200% of nominal current for 0.5sVoltage: +10 to -15% (Voltage unbalance:2% or less *8, Frequency: +5 to -5%) *85 to 9%7 to 12%7 to 12%10 to 15%Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% (ND spec.), 0 to 80% (HD/HND spec.), 0 to 100% (HHD spec.) of nominal currentOptionOptionOptionOptionOptionIP00, UL open typeFan coolingOverload capabilityMain power supplyRated current without DCR *5 [A] Rated current with DCR *5 [A] Required power supply capacity *6 [kVA]Braking torque *7 [%]Braking chopperMinimum connection resistance[ohm]Braking resistorDC braking DC reactor (DCR)Enclosure (IEC60529)Cooling methodMass [kg]Voltage/frequency variationsRated current [A] *4SpecificationsItemsStandard Model SpecificationsThree phase 400V class seriesOutput ratingsInput ratingsBraking*1 Fuji 4-pole standard motor. At the selection of the inverter rating, consider not only the rating capacity(kW) is enough but also inverter output current is larger than selected the motor's nominal current.*2 Rated capacity is calculated by assuming the output rated voltage as 440 V.*3 Output voltage cannot exceed the power supply voltage.*4 When the carrier frequency (F26) is set to below value or higher, the inverter is sure to be necessary to derate their nominal current. HHD spec.---type 0002 to 0012 : 8kHz, type 0022 to 0168 : 10kHz, type 0203 to 0590 : 6kHz HND spec.---type 0002 to 0012 : 8kHz, type 0022 to 0059 : 10kHz, type 0072 to 0168 : 6kHz, type 0203 to 0590 : 4kHz HD,ND spec.---All type : 4kHz The rated output current at HD/ND spec. is decreased 2% for every 1 °C (1.8 °F) when ambient temperature is +40 °C (+104 °F) or more. *5 The value is calculated assuming that the inverter is connected with a power supply with the capacity of 500 kVA (or 10 times the inverter capacity if the inverter capacity exceeds 50 kVA) and %X is 5%. Be sure to use the DCR when applicable motor capacity is 75kW or above. *6 Obtained when a DC reactor (DCR) is used.*7 Average braking torque for the motor running alone. (It varies with the efficiency of the motor.)*8 Voltage unbalance (%) =(Max. voltage (V) - Min. voltage (V))/Three -phase average voltage (V) × 67 (IEC 61800 - 3) If this value is 2 to 3%, use an optional AC reactor (ACR).*9 The 400 V class series with type 0203 or above is equipped with a set of switching connectors (male) which should be configured according to the power source voltage and frequency.Three-phase 380 to 440V, 50Hz *9Three-phase 380 to 480V, 60HzThree-phase 380 to 480V, 50/60HzTypeFRN E2S-4GB016890(125)75(100)75(100)55(75)12811411485168150150112---140164138138102114969671-33013975(100)55(75)55(75)45(60)10685856913911211291.0-14014011413810210283.296717158-300203110(150)90(125)90(125)75(100)155134134114203176176150----20116416413813911411496-400240132(200)110(150)110(150)90(125)183160160134240210210176----238201201164165140140114-620290160132(200)132(200)110(150)221193193160290253253210----286238238201199165165140-630361200(300)160(250)160(250)132(200)275232232193361304304253----357286286238248199199165-950415220(350)200(300)200(300)160(250)316287287232415377377304----390357357286271248248199-960520280(450)220(350)220(350)200(300)396316316287520415415377----500390390357347271271248-1300590315(500)250(400)280(450)220(350)450364396316590477520415----559443500390388307347271-140008545(60)37(50)37(50)30(40)6557574685.075.075.060.011494.394.377.983.268.568.557.058474739-25010555(75)45(60)45(60)37(50)8069695710591.091.075.014011411494.310283.283.268.571585847-266Major FunctionsCommon SpecificationsBasic Wiring DiagramTerminal FunctionsExternal DimensionsOptionsStandard Model SpecificationsThree phase 200V class seriesHNDHHDHNDHHDHNDHHDHNDHHDHNDHHDHNDHHDHNDHHDHNDHHDHNDHHDNominal applied motor *1 [kW(HP)]Rated capacity [kVA] *2Rated voltage [V] *3Three-phase 200 to 240V (With AVR)120% of nominal current for 1min150% of nominal current for 1min or 200% of nominal current for 0.5sThree-phase 200 to 240V, 50/60HzVoltage: +10 to -15% (Voltage unbalance:2% or less *8, Frequency: +5 to -5%)Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s,Braking level: 0 to 60% (ND spec.), 0 to 80% (HD/HND spec.), 0 to 100% (HHD spec.) of nominal currentOverload capabilityMain power supplyRated current without DCR *5 [A] Rated current with DCR *5 [A] Required power supply capacity *6 [kVA]Braking torque *7 [%]Braking chopperMinimum connection resistance[ohm]Braking resistorDC brakingDC reactor (DCR)Enclosure (IEC60529)Cooling methodMass [kg] Voltage/frequency variationsRated current [A] *4SpecificationsItems004011(15)7.5(10)1513403360.742.742.228.81510155.075%150%Built-inOptionOptionOptionIP20, UL open typeNaturalural cooling15%20%100%40%Fan cooling00307.5(10)5.5(7.5)119.5302542.731.528.821.1107.3205.0 00010.2(1/4)0.1(1/8)0.50.31.30.81.81.10.930.570.40.20.500020.4(1/2)0.2(1/4)0.80.62.01.62.61.81.60.930.60.40.500040.75(1)0.4(1/2)1.31.13.53.04.93.13.01.61.10.653%0.600061.1(1.5)0.75(1)2.31.96.05.06.75.34.33.01.51.168%0.800102.2(3)1.5(2)3.73.09.68.012.89.58.35.72.92.048%70%1.500123.0(4)*102.2(3)4.6*104.212*101117.9*1013.211.7*108.34.1*102.929%*101.500205.5(7.5)*103.7(5)7.5*106.719.6*1017.531.9*1022.219.9*1014.06.9*104.927%*10331.8005615(20)11(15)2118564780.060.757.642.22015108.0006918.5(25)15(20)2623696097.080.071.057.625208.69.0008822(30)18.5(25)3429887611297.084.471.030259.5011530(40)22(30)44341159015111211484.4403010Output ratingsInput ratingsBrakingStandard Model Specifications*1 Fuji 4-pole standard motor. At the selection of the inverter rating, consider not only the rating capacity(kW) is enough but also inverter output current is larger than selected the motor's nominal current.*2 Rated capacity is calculated by assuming the output rated voltage as 220 V.*3 Output voltage cannot exceed the power supply voltage.*4 When the carrier frequency (F26) is set to below value or higher, the inverter is sure to be necessary to derate their nominal current. HHD spec.---type 0001 to 0020 : 8kHz, type 0030 to 0115 : 10kHz, HND spec.---type 0001 to 0020 : 4kHz, type 0030 to 0069 : 10kHz, type 0088,0115 : 4kHz*5 The value is calculated assuming that the inverter is connected with a power supply with the capacity of 500 kVA (or 10 times the inverter capacity if the inverter capacity exceeds 50 kVA) and %X is 5%.*6 Obtained when a DC reactor (DCR) is used.*7 Average braking torque for the motor running alone. (It varies with the efficiency of the motor.)*8 Voltage unbalance (%) =(Max. voltage (V) - Min. voltage (V))/Three -phase average voltage (V) × 67 (IEC 61800 - 3) If this value is 2 to 3%, use an optional AC reactor (ACR).*10 HND spec. of the type 0012 and 0020: allowable ambient temperature 40 °C (+104 °F) or less. The rated output current at HND spec. is decreased 1% for every 1 °C (1.8 °F) when ambient temperature is +40 °C (+104 °F) or more.TypeFRN E2S-2GA,FRN E2S-2GBFRN E2S-2GB401004FUJI ELECTRIC INVERTERS7Single phase 200V class series (Basic Type)HHDHHDHHDHHDHHDHHDHHDHHDHHDNominal applied motor *1 [kW(HP)]Rated capacity [kVA] *2Rated voltage [V] *3Three-phase 200 to 240V (With AVR)150% of nominal current for 1min or 200% of nominal current for 0.5sThree-phase 200 to 240V, 50/60HzVoltage: +10 to -15% (Voltage unbalance:2% or less *8, Frequency: +5 to -5%)Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s,Braking level: 0 to 100% (HHD spec.) of nominal currentOverload capabilityMain power supplyRated current without DCR *5 [A] Rated current with DCR *5 [A] Required power supply capacity *6 [kVA]Braking torque *7 [%]DC brakingBraking chopperMinimum connection resistance [ohm]Braking resistorDC reactor (DCR)Enclosure (IEC60529)Cooling methodMass [kg] Voltage/frequency variationsRated current [A] *4SpecificationsItems150%Built-in100OptionOptionIP20, UL open typeNaturalural cooling100%40%70%Fan cooling40 00010.1(1/8)0.30.81.81.10.30.5 00020.2(1/4)0.61.63.32.00.40.5 00030.4(1/2)1.13.05.43.50.70.6 00050.75(1)1.95.09.76.41.30.9 00081.5(2)3.08.016.411.62.41.6 00112.2(3)4.21124.817.53.51.8Output ratingsInput ratingsBraking*1 Fuji 4-pole standard motor. At the selection of the inverter rating, consider not only the rating capacity(kW) is enough but also inverter output current is larger than selected the motor's nominal current.*2 Rated capacity is calculated by assuming the output rated voltage as 220 V.*3 Output voltage cannot exceed the power supply voltage.*4 When the carrier frequency (F26) is set to below value or higher, the inverter is sure to be necessary to derate their nominal current. HHD spec.---type 0001 to 0011 : 8kHz*5 The value is calculated assuming that the inverter is connected with a power supply with the capacity of 500 kVA (or 10 times the inverter capacity if the inverter capacity exceeds 50 kVA) and %X is 5%.*6 Obtained when a DC reactor (DCR) is used.*7 Average braking torque for the motor running alone. (It varies with the efficiency of the motor.)Standard Model SpecificationsTypeFRN E2S-7GA, FRN E2S-7GB8Major FunctionsCommon SpecificationsBasic Wiring DiagramTerminal FunctionsExternal DimensionsOptionsStandard Model SpecificationsTypeEMC Filter Built-in Type SpecificationsNDHDHNDHHDNDHDHNDHHDNDHDHNDHHDND, HNDHDHHDNDHDHNDHHDNDHDHNDHHDNDHDHNDHHDNDHDHNDHHDNDHND, HDHHDNominal applied motor *1 [kW]Rated capacity [kVA] *2Rated voltage [V] *3Three-phase 380 to 480V (With AVR) 120% of nominal current for 1min150% of nominal current for 1min150% of nominal current for 1min or 200% of nominal current for 0.5sThree-phase 380 to 480V, 50/60HzVoltage: +10 to -15% (Voltage unbalance:2% or less *8, Frequency: +5 to -5%)Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% (ND spec.), 0 to 80% (HD/HND spec.), 0 to 100% (HHD spec.) of nominal currentBuilt-inOptionOptionOptionOptionIP20, UL open typeNatural coolingOverload capabilityMain power supplyRated current without DCR *5 [A] Rated current with DCR *5 [A] Required power supply capacity *6 [kVA]Braking torque *7 [%]Braking chopperMinimum connection resistance [ohm]Braking resistorDC braking DC reactor (DCR)Enclosure (IEC60529)Cooling methodMass [kg]Voltage/frequency variationsRated current [A] *4SpecificationsItems00291511117.52218181428.523.023.018.043.833.033.023.228.821.121.114.420151510606.50022117.57.55.51613139.921.517.517.513.033.023.223.217.321.114.414.410.61510107.3806.500020.750.750.750.41.61.41.41.12.11.81.81.52.72.72.71.71.51.51.50.851.11.11.10.653%53%53%1.500041.51.11.10.753.12.62.61.94.13.43.42.54.83.93.93.12.12.12.11.61.51.51.51.250%68%68%1.800062.22.22.21.54.23.83.83.25.55.05.04.27.37.37.35.94.24.24.23.03.03.03.02.148%48%48%70%2.300073.03.03.0*92.25.34.84.8*94.26.96.36.3*95.511.311.311.3*98.25.85.85.8*94.44.14.14.1*93.129%29%29%*92.300125.55.55.5*93.79.18.58.5*96.91211.111.1*99.016.816.816.8*913.010.110.110.1*97.37.07.07.0*95.127%27%27%*91302.4003718.51515112824241837.031.031.024.052.343.843.833.035.528.828.821.1252020154011.200442218.518.5153429292344.038.038.030.060.652.352.343.842.235.535.528.82925252034.411.2005930222218.54534343059.045.045.039.077.960.660.652.357.042.242.235.53929292510.50072373030225546463472.060.060.045.094.377.977.960.668.557.057.042.24739392911.2Three phase 400V class seriesOutput ratingsInput ratingsBrakingEMC filterCompliant with EMC Directives,Emission: Category C3. Immunity:Category C3(2nd Env.)(EN61800-3:2004)Compliant with EMC Directives,Emission: Category C2. Immunity: Category C3 (2nd Env.)(EN61800-3: 2004)(Pending)12%15%15%20%Fan cooling100%2001601640%*1 Fuji 4-pole standard motor. At the selection of the inverter rating, consider not only the rating capacity(kW) is enough but also inverter output current is larger than selected the motor's nominal current.*2 Rated capacity is calculated by assuming the output rated voltage as 440 V.*3 Output voltage cannot exceed the power supply voltage.*4 When the carrier frequency (F26) is set to below value or higher, the inverter is sure to be necessary to derate their nominal current. HHD spec.---type 0002 to 0012 : 8kHz, type 0022 to 0168 : 10kHz, type 0203 to 0590 : 6kHz HND spec.---type 0002 to 0006 : 8kHz, type 0007 to 0012 : 4kHz, type 0022 to 0168 : 6kHz, type 0203 to 0590 : 4kHz HD,ND spec.---All type : 4kHz*5 The value is calculated assuming that the inverter is connected with a power supply with the capacity of 500 kVA (or 10 times the inverter capacity if the inverter capacity exceeds 50 kVA) and %X is 5%.Be sure to use the DCR when applicable motor capacity is 75kW or above.*6 Obtained when a DC reactor (DCR) is used.*7 Average braking torque for the motor running alone. (It varies with the efficiency of the motor.)*8 Voltage unbalance (%) =(Max. voltage (V) - Min. voltage (V))/Three -phase average voltage (V) × 67 (IEC 61800 - 3) If this value is 2 to 3%, use an optional AC reactor (ACR).*9 HND spec. of the type 0007 and 0012: allowable ambient temperature 40℃ (+104 °F) or less. The rated output current at HND spec. is decreased 1% for every 1 ℃ (1.8 °F) when ambient temperature is +40 ℃ (+104 °F) or more.FRN E2E-4GAFRN E2E-4EFUJI ELECTRIC INVERTERS9Next >