SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK CURRENT PEAK POWER Note.6 OUTPUT VOLTAGEADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UPTIME (Typ.) VOLTAGE RANGE Note.7 FREQUENCYRANGE EFFICIENCY(Typ.)INPUT INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER TEMPERATURE SAFETYSTANDARDS WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MTBF DIMENSIONOTHERS NOTE PACKING OVERLOAD OVER VOLTAGE AC CURRENT (Typ.) 1500ms, 60ms/230VAC 3000ms, 60ms/115VAC at full load 20ms/230VAC 20ms/115VAC at full load 88 ~ 264VAC 124 ~ 370VDC 47 ~ 63Hz 89% 0.93/230VAC 0.96/115VAC at full load 1.4A/115VAC 0.7A/230VAC 29 ~ 33V 91% 56 ~ 65V 90.5% 35A/115VAC 70A/230VAC <1mA/ 240VAC Normally wmore than 3and then shut down o/p voltageorks within 110 ~ 150% rated output power forseconds 14 ~ 17V >150% rated power, constant current limiting with auto-recovery within 3 seconds and shut down o/p voltage after 3 seconds Protection type : Shut down o/p voltage, re-power on to recover 955(TSW) detect on heatsink of power switch ℃±℃ Protection type : Shut down o/p voltage, recovers automatically after temperature goes down Ul508,TUV EN60950-1 approved ;(meet EN60204-1) Compliance to EN55011, EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteriaA, SEMI F47, GLapproved -25 ~ +70(Refer to "Derating Curve") ℃ 60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5Aresistive load 20 ~ 95% RH non-condensing -40 ~ +85, 10 ~ 95% RH ℃ ±℃℃ 0.03%/(0 ~ 50 ) Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X,Y, Z axes; Mounting: Compliance to IEC60068-2-6 289.9K hrs min. MIL-HDBK-217F (25) ℃ 40*125.2*113.5mm (W*H*D) 0.67Kg; 20pcs/14.4Kg/1.16CUFT POWER FACTOR (Typ.) SDR-120-24SDR-120-48 24V48V 5A2.5A 0 ~ 5A0 ~ 2.5A 120W120W 7.5A3.75A 100mVp-p120mVp-p 24 ~ 28V48 ~ 55V ± 1.0% ± 1.0% ± 0.5% ± 0.5% ± 1.0% ± 1.0% SDR-120-12 12V 10A 0 ~ 10A 120W 15A 180W (3 sec.) 100mVp-p 12 ~ 14V ± 1.0% ± 0.5% ± 1.0% ■ Features : SDR-120 series WITHSTAND VOLTAGE ISOLATION RESISTANCE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25/ 70% RH ℃ SAFETY& FUNCTION EMC (Note 4) RIPPLE & NOISE (max.) Note.2 VOLTAGE TOLERANCE Note.3 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃ 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. 6. 3 seconds max., please refer to peak loading curves. 7. Derating may be needed under low input voltage. Please check the derating curve for more details. 120W Single Output Industrial DIN RAILwith PFC Function .. High efficiency 91% and low power dissipation 150% peak load capability Built-in active PFC function, PF>0.93 Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 UL 508 (industrial control equipment) approved EN61000-6-2(EN50082-2) industrial immunity level Built-in DC OK relay contact 100% full load burn-in test 3 years warranty File Name:SDR-120-SPEC 2017-07-07 GL PQ S E M I F 4 7 EMC IMMUNITY EMC EMISSIONMechanical Specification Block Diagram Case No.992AUnit:mm DC OK Relay Contact DETECTION PWM & PFCCIRCUIT O.L.P.U.V.P. EMI FILTER RECTIFIERS POWER SWITCHING FILTER & RECTIFIERS +V DC OK -V I/P FG CONTROL O.V.P. & O.C.P. PFC CIRCUIT PFC CONTROL Terminal Pin No.Assignment (TB1) Terminal Pin No.Assignment (TB2) Pin No. Pin No. 1 1,2 2 3 4 3 Assignment Assignment FG AC/L AC/N DC OUTPUT-V DC OUTPUT+V ADMISSIBLE DIN-RAIL:TS35/7.5 ORTS35/15 35 Relay Contact 1 2 3 125.2 113.5 40 TB1 Contact ClosePSU turns on / DC OK. PSU turns off / DC Fail. 30V/1Aresistive load. Contact Open Contact Ratings (max.) SDR-120 series 120W Single Output Industrial DIN RAILwith PFC Function + 2 3 4 1 TB2 DC OK DC OK +VADJ. File Name:SDR-120-SPEC 2017-07-07180W ( 1 )( 2 ) 120W 100 sec.3 sec. 180W 60W 15 sec.3 sec. -250 Continuous For 3 sec. (typ.) 1020304050556070 60 75 100 125 150 (VERTICAL) 12V Others 12V Others SDR-120 series 120W Single Output Industrial DIN RAILwith PFC Function INPUT VOLTAGE (V) 60Hz LOAD (%) AMBIENT TEMPERATURE () ℃ LOAD (%) 100 40 88110 50 60 70 80 155135230264 90 100 Output derating VS input voltageDerating Curve Peak Loading File Name:SDR-120-SPEC 2017-07-07Next >