SPECIFICATION MDR-40-5MDR-40-12MDR-40-24MDR-40-48 MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUTVOLTAGEADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME Note.5 HOLD UPTIME (Typ.) VOLTAGE RANGE FREQUENCYRANGE EFFICIENCY(Typ.) AC CURRENT (Typ.) INPUT INRUSH CURRENT (Typ.) SAFETYSTANDARDS WORKING HUMIDITY WORKING TEMP. DC OK SIGNAL STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MTBF DIMENSIONOTHERS NOTE PACKING OVERLOAD OVER VOLTAGE 5V12V24V48V 6A3.33A1.7A0.83A 0 ~ 6A0 ~ 3.33A0 ~ 1.7A0 ~ 0.83A 30W40W40.8W39.8W 80mVp-p120mVp-p150mVp-p 24 ~ 30V 200mVp-p 48 ~ 56V ± 2.0% ± 1.0% ± 1.0% ± 1.0% 12 ~ 15V5 ~ 6V ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load 50ms/230VAC 20ms/115VAC at full load 85 ~ 264VAC 120 ~ 370VDC 47 ~ 63Hz 78%86%88%88% 1.1A/115VAC 0.7A/230VAC COLD START30A/115VAC 60A/230VAC 105 ~ 150% rated output power Protection type :Constant current limiting, recovers automatically after fault condition is removed 6.25 ~ 7.25V Protection type : Shut down o/p voltage, re-power on to recover 15.6 ~ 18V31.2 ~ 36V57.6 ~ 64.8V -20 ~ +70(Refer to "Derating Curve") ℃ Relay contact rating(max.): 30V/1Aresistive 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH ℃ ±℃℃ 0.03%/(0 ~ 50 ) Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,Y, Z axes ; Mounting : Compliance to IEC60068-2-6 301.7K hrs min. MIL-HDBK-217F (25) ℃ 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃ 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. File Name:MDR-40-SPEC 2017-07-07 UL508, UL60950-1,TUV EN60950-1,approvedClass I, Div. 2 GroupA, B, C, D HazardousLocationsT4 Compliance to EN55011, EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3 Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteriaA 40W Single Output Industrial DIN Rail Power Supply MDR-40 series RIPPLE & NOISE (max.) Note.2 VOLTAGE TOLERANCE Note.3 SAFETY& FUNCTION EMC (Note 4) WITHSTAND VOLTAGE ISOLATION RESISTANCE Universal AC input/Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 Class I, Div 2 Hazardous Locations T4 LED indicator for power on DC OK relay contact No load power consumption<0.75W 100% full load burn-in test 3 years warranty ■ Features : 40*90*100mm (W*H*D) 0.3Kg; 42pcs/13.6Kg/0.82CUFT .. LEAKAGE CURRENT <1mA/ 240VAC I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25/ 70% RH ℃ EMC IMMUNITY EMC EMISSIONBlock Diagram DC OK Relay Contact Mechanical Specification -20010203045556070(VERTICAL) 20 40 60 80 100 AMBIENT TEMPERATURE ()℃ LOAD (%) CIRCUIT DETECTION O.L.P. EMI FILTER RECTIFIERS & FILTER POWER SWITCHING FILTER & RECTIFIERS +V DC OK -V I/P CONTROL O.V.P. O.C.P. Output Derating VS Input Voltage INPUT VOLTAGE (VAC) 60Hz 8510095120115160140200180240220264 LOAD (%) 90 100 80 70 60 50 40 Derating Curve + Install DIN railTS35/7.5 orTS35/15 35 +V+V 90 40 -V-V NL DC OK +VADJ 55555 7.57.5 100 fosc : 60KHz DC OK Contact ClosePSU turns on / DC OK. PSU turns off / DC Fail. 30V/1Aresistive load. Contact Open Contact Ratings (max.) FG Case No.962AUnit:mm 40W Single Output Industrial DIN Rail Power Supply MDR-40 series File Name:MDR-40-SPEC 2017-07-07Next >