WGVL • en-us • 2021-09-27 • Subject to change1 / 2 WGVL2" [50 mm] Fluidchilled or hot water and steam Fluid Temp Range (water)Please Refer to Manufacturer's Valve Specifications Mounting Position360° Applicable Valve Size2...6" [50...150] HardwareSS and Nickel plated steel Housing materialDie cast aluminium and plastic casing Spindle316 stainless steel Stem adaptersteel Frame, plate, basealuminum, steel (fits Warren Type 20,22,23,30, and 32) and Belimo G6/G7 Collarsteel CouplingGF Nylon supplied Non-SpringEVB(X) RVB(X) Electrical fail-safeAVKB(X) For close-off pressure reference Select Pro or retrofit technical documentation. The default set up for a WGVL linkage will be factory installed along with an AVK or EV, RV series actuator. Included in the kit will be all the necessary hardware to facilitate mounting to the Warren valve. EVB, EVX, RVB, RVX 10.2" [260]5.5" [140]9.2" [234]12.2" [310]WGVL • en-us • 2021-09-27 • Subject to change2 / 2 AVKB, AVKX 10.4" [264]5.5" [140]10.3" [262]10.9" [276]EVX24-MFT • en-us • 2021-12-02 • Subject to change1 / 3 Nominal voltageAC/DC 24 V Nominal voltage frequency50/60 Hz Power consumption in operation5 W Power consumption in rest position1.5 W Transformer sizing7.5 VA (class 2 power source) Electrical Connection18 GA plenum cable, 3 ft [1 m], with 1/2" conduit connector, degree of protection NEMA 2 / IP54 Overload Protectionelectronic throughout full stroke Electrical Protectionactuators are double insulated Actuating force motor2500 N [560 lbf] Operating range Y2...10 V Operating range Y note4...20 mA w/ ZG-R01 (500 Ω, 1/4 W resistor) Input Impedance100 kΩ for 2...10 V (0.1 mA), 500 Ω for 4...20 mA, 1500 Ω for PWM, On/Off and Floating point Operating range Y variableStart point 0.5...30 V End point 2.5...32 V Options positioning signalvariable (VDC, PWM, on/off, floating point) Position feedback U2...10 V Position feedback U noteMax. 0.5 mA Position feedback U variableVDC variable Direction of motion motorselectable with switch 0/1 Manual override5 mm hex crank (3/16" Allen), supplied Stroke2" [50 mm] Running Time (Motor)90 s / Running time motor variable90...150 s Noise level, motor60 dB(A) Position indicationMechanically, with pointer Degree of protection IEC/ENIP54 Degree of protection NEMA/ULNEMA 2 EnclosureUL Enclosure Type 2 Agency ListingcULus acc. to UL60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2014/30/EU and 2014/35/EU; Listed to UL 2043 - suitable for use in air plenums per Section 300.22(c) of the NEC and Section 602.2 of the IMC Quality StandardISO 9001 Ambient temperature-22...122°F [-30...50°C] Storage temperature-40...176°F [-40...80°C] Ambient humidityMax. 95% RH, non-condensingEVX24-MFT • en-us • 2021-12-02 • Subject to change2 / 3 Servicingmaintenance-free Housing materialDie cast aluminium and plastic casing † Use flexible metal conduit. Push the listed conduit fitting device over the actuator’s cable to butt against the enclosure. Screw in conduit connector. Jacket the actuators input wiring with listed flexible conduit. Properly terminate the conduit in a suitable junction box. Rated impulse Voltage 800V. Type of action 1. Control pollution degree 3. Gateway MP to BACnet MS/TPUK24BAC Gateway MP to Modbus RTUUK24MOD Gateway MP to LonWorksUK24LON Belimo PC-Tool, Software for adjustments and diagnosticsMFT-P Auxiliary switch 2 x SPDT for NG GV ActuatorsS2A-GV Service Tool, with ZIP-USB function, for programmable and communicative Belimo actuators, VAV controller and HVAC performance devices ZTH US Connection cable 10 ft [3 m], A: RJ11 6/4 ZTH EU, B: 3-pin Weidmüller and supply connection ZK4-GEN Service Tool, with ZIP-USB function, for programmable and communicative Belimo actuators, VAV controller and HVAC performance devices ZTH US Actuators may be connected in parallel. Power consumption and input impedance must be observed. Actuators may also be powered by DC 24 V. A 500 Ω resistor (ZG-R01) converts the 4...20 mA control signal to 2...10 V. Control signal may be pulsed from either the Hot (Source) or Common (Sink) 24 V line. For triac sink the common connection from the actuator must be connected to the hot connection of the controller. Contact closures A & B also can be triacs. A & B should both be closed for the triac source and open for triac sink. Actuators with plenum cable do not have numbers; use color codes instead. Meets cULus requirements without the need of an electrical ground connection. During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury.EVX24-MFT • en-us • 2021-12-02 • Subject to change3 / 3 On/OffFloating Point VDC / 4 to 20 mAOverride Control Min, Mid, Max PositionsNext >