Technical Data127479Servicechilled or hot water and steamApplicable Valve Size1/2” [13], 3/4” [19], 1” [25], 1-1/4” [32], 1-1/2” [38], 2” [50]Frame, plate, basealuminum, steelCollaraluminum, steel, (fits bonnets up to 1.7” dia both threaded or notched.)CouplingGF Nylon suppliedStem Adaptoraluminum, steel (fits stems up to .66” dia both threaded or slotted.)Stroke0.6” [15 mm] LV, 3/4” [20 mm] SVMounting Position360°Media Temperature Range (Water)20°F to 250°F [-7°C to 120°C]Media Temperature Range (Steam)32°F to 338°F [0°C to 170°C]Weight4.2 lb [1.9 kg]For close-off pressure reference Select Pro or Retrofit Technical Documentation.ApplicationThe UGVL retrofit kit is designed to easily attach LV and SV series actuators to select globe valves. Its unique adjustable design allows the UGVL to be mounted on ½” to 2” two-way or three-way valves in both normally open and normally closed configurations.OperationThe UGVL linkage with actuator will provide 20 mm of linear travel to accommodate a wide range of valves.Default/ConfigurationThe default set up for a UGVL linkage will be factory installed along with a LV or SV series actuator. Included in the kit will be all the necessary hardware to facilitate mounting to the valve.Suitable Actuators Non-SpringElectronic Fail-SafeUGVLLVB(X), SVB(X)LVKB(X), SVKB(X)Dimensions (Inches [mm])CABH1H2LVB, LVX, SVB, SVXABCH1H28” [203]4.4” [113]8.60” [218]7.5” [190]11.4” [290]UGVL Universal Globe Valve LinkageFor Use with LV and SV Series Actuators800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEANDate created, 08/14/2016 - Subject to change. © Belimo Aircontrols (USA), Inc.Dimensions (Inches [mm])CAH2BH1LVKB, LVKX, SVKB, SVKXABCH1H28.5” [217]4.4” [113]9.6” [244]8.4” [207]12.1” [307]UGVL Universal Globe Valve LinkageFor Use with LV and SV Series Actuators800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEANDate created, 08/14/2016 - Subject to change. © Belimo Aircontrols (USA), Inc.Technical Data148123Power Supply24 VAC ± 20%, 50/60 Hz, 24 VDC ± 10%Power Consumption Running1.5 W Power Consumption Holding2 W Transformer Sizing4 VA (class 2 power source)Electrical Connection3 ft, 18 GA plenum rated cable with 1/2” conduit connector protected NEMA 2 (IP54)Overload Protectionelectronic throughout full strokeElectrical Protectionactuators are double insulatedOperating Range Y2 to 10 VDC, 4 to 20 mA w/ ZG-R01 (500 Ω, 1/4 W resistor)Input Impedance100 k Ω for 2 to 10 VDC (0.1 mA), 500 Ω for 4 to 20 mAFeedback Output U2 to 10 VDCStroke0.6” [15 mm] LV, 3/4” [20 mm] SVLinear Force337 lbf [1500 N force] Direction of Rotation (Motor)reversible with switchPosition Indicationstroke indicator on bracketManual Override4 mm hex crank (shipped w/actuator)Running Time (Motor)90 sec, constant independent of loadHumidity5 to 95% RH non-condensingAmbient Temperature Range-22°F to +122°F [-30°C to +50°C]Storage Temperature Range-40°F to +176°F [-40°C TO +80°C]HousingNEMA 2, IP42, UL enclosure type 2Housing MaterialAluminum die cast and plastic casingAgency Listings†cULus acc. to UL60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EC and 2006/95/ECNoise Level (Motor)<45 dB (A) Servicingmaintenance freeQuality StandardISO 9001Weight2.9 lb [1.3 kg]† Use flexible metal conduit. Push the listed conduit fitting device over the actuator’s cable to butt against the enclosure. Screw in conduit connector. Jacket the actuators input wiring with listed flexible conduit. Properly terminate the conduit in a suitable junction box. Rated impulse Voltage 800V. Type of action 1. Control pollution degree 3.SVB24-SRModulating, Non-Spring Return, Linear, 24 V, for 2 to 10 VDC or 4 to 20 mA800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEANDate created, 08/14/2016 - Subject to change. © Belimo Aircontrols (USA), Inc.Wiring DiagramsINSTALLATION NOTESActuators may also be powered by 24 VDC.Only connect common to negative (-) leg of control circuits.A 500 Ω resistor (ZG-R01) converts the 4 to 20 mA control signal to 2 to 10 VDC.Actuators with plenum cable do not have numbers; use color codes instead.Meets cULus requirements without the need of an electrical ground connection.!WARNING! LIVE ELECTRICAL COMPONENTS!During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Blk (1) - CommonRed (2) + HotWht (3) Y InputOrg (5) U Input24 VAC TransformerControl Signal (+)VDC/mA(–)Feedback Signal (+)2 to 10 VDC(–)500LineVolts37518VDC / 4 to 20 mASVB24-SRModulating, Non-Spring Return, Linear, 24 V, for 2 to 10 VDC or 4 to 20 mA800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEANDate created, 08/14/2016 - Subject to change. © Belimo Aircontrols (USA), Inc.Next >