Technical Data140310Servicechilled or hot water and steamApplicable Valve Size1/2” [13], 3/4” [19], 1” [25], 1-1/4” [32], 1-1/2” [38], 2” [50]HardwareSS and Nickel plated steelFrame, plate, basealuminumCollaraluminum (fits VB7 1/2” to 2” /VB9 1/2”-1-1/4” valves) also fits post 1994 1-1/2” to 2” valvesCouplingGF Nylon suppliedStem AdaptorsteelStroke0.95” [24 mm]Mounting Position360°Media Temperature Range (Water)Please Refer to Manufacturer’s Valve SpecificationsWeight1.1 lb [0.5 kg]For close-off pressure reference Select Pro or Retrofit Technical Documentation.ApplicationThe SGVL retrofit kit is designed to easily attach LV and SV series actuators to select Schneider globe valves. Its casted base and free spinning collar allow the SGVL to be mounted on ½” to 2” two-way or three-way valves in both normally open and normally closed configurations.OperationThe SGVL linkage with actuator will provide 20 mm of linear travel to accommodate a wide range of valve sizes.Default/ConfigurationThe default set up for a SGVL linkage will be factory installed along with a LV or SV series actuator. Included in the kit will be all the necessary hardware to facilitate mounting to the Schneider valve.Suitable Actuators Non-SpringElectronic Fail-SafeSGVLLVB(X), SVB(X)LVKB(X), SVKB(X)Dimensions (Inches [mm])CABLVB, LVX, SVB, SVXABC6” [152]3.83” [97.3]7.87” [200]SGVL Schneider Globe Valve LinkageFor Use with LV and SV Series Actuators800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEANDate created, 12/06/2016 - Subject to change. © Belimo Aircontrols (USA), Inc.Dimensions (Inches [mm])BCAABC6.75” [171]3.83” [97.3]8.13” [206.5]SGVL Schneider Globe Valve LinkageFor Use with LV and SV Series Actuators800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEANDate created, 12/06/2016 - Subject to change. © Belimo Aircontrols (USA), Inc.Technical Data286274Power Supply24 VAC ± 20%, 50/60 Hz, 24 VDC ± 10%Power Consumption Running2 W Power Consumption Holding1.5 W Transformer Sizing3.5 VA (class 2 power source)Electrical Connection3 ft, 18 GA plenum rated cable with 1/2” conduit connector protected NEMA 2 (IP54)Overload Protectionelectronic throughout full strokeElectrical Protectionactuators are double insulatedOperating Range Yon/off, floating pointInput Impedance100 k Ω (0.1 mA), 500 Ω, 1000 Ω (on/off)Feedback Output UNo FeedbackStroke0.6” [15 mm] LV, 3/4” [20 mm] SVLinear Force337 lbf [1500 N force] Direction of Rotation (Motor)reversible with switchPosition Indicationstroke indicator on bracketManual Override4 mm hex crank (shipped w/actuator)Running Time (Motor)90 sec (default), Optional (90 or 150 sec)Humidity5 to 95% RH non-condensingAmbient Temperature Range-22°F to 122°F [-30°C to 50°C]Storage Temperature Range-40°F to 176°F [-40°C to 80°C]HousingNEMA 2, IP42, UL enclosure type 2Housing MaterialAluminum die cast and plastic casingAgency Listings†cULus acc. to UL60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EC and 2006/95/ECNoise Level (Motor)<45 dB (A) Servicingmaintenance freeQuality StandardISO 9001Weight2.9 lb [1.3 kg]† Use flexible metal conduit. Push the listed conduit fitting device over the actuator’s cable to butt against the enclosure. Screw in conduit connector. Jacket the actuators input wiring with listed flexible conduit. Properly terminate the conduit in a suitable junction box. Rated impulse Voltage 800V. Type of action 1. Control pollution degree 3.SVX24-3On/Off, Floating Point, Non-Spring Return, Linear, 24 V800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEANDate created, 11/03/2016 - Subject to change. © Belimo Aircontrols (USA), Inc.Wiring DiagramsINSTALLATION NOTESActuators may be connected in parallel. Power consumption and input impedance must be observed.Actuators may also be powered by 24 VDC.Actuators with plenum cable do not have numbers; use color codes instead.Meets cULus requirements without the need of an electrical ground connection.!WARNING! LIVE ELECTRICAL COMPONENTS!During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. 24 VAC TransformerBlk (1) - CommonRed (2) +Wht (3) +LineVolts2318On/Off Blk (1) - CommonRed (2) + Wht (3) +LineVolts24 VAC Transformer2318Floating Point 24 VAC Transformer (AC only)LineVoltsHotControllerComBlk (1) - CommonRed (2) + HotWht (3) Y1 Input218Triac Source ComLineVoltsHotController24 VAC Transformer (AC only)Blk (1) - CommonRed (2) + HotWht (3) Y1 Input218Triac SinkSVX24-3On/Off, Floating Point, Non-Spring Return, Linear, 24 V800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEANDate created, 11/03/2016 - Subject to change. © Belimo Aircontrols (USA), Inc.Next >