1INSTALLATION INSTRUCTIONSFlanged Globe Valves 2½” to 6”Pressure Compensated G6…C SeriesFEATURES• Balanced Plug Design• Spring Return Solutions for up to 6” Valves• Bronze or Stainless TrimBENEFITS• Perfect for high close-off requirements• Fail-safe on larger valves• Covers wide range of operating temperatures• Equal percent (G6C) (G6CS) or linear characteristic (G6LCS) for steam applicationsG6…CTwo-way Pressure CompensatedG6…CSTwo-way Pressure Compensated Stainless Steel TrimG6...LCSTwo-way Pressure Compensated Stainless Steel TrimLinear Characteristic2½” to 6”ServiceChilled/hot water, 60% glycol, steamCv Range65 – 344MaterialStainless steel stem, Bronze plug or Stainless plugControlOn/Off, Floating PointMulti-Function Technology®Electronic Fail-Safe or Non-Spring Return2FEATURES• Complete flanged product range• Mixing or diverting options• Multi-Function Technology®• ANSI 125/ANSI 250BENEFITS• Fits wide range of applications• Capable of any control signal• Suitable for piping systemsG6…C(S)-250Two-way Flanged ANSI 250 Bronze or Stainless TrimG7…(S)Three-way Flanged Bronze or Stainless TrimG7…(S)-250Three-way Flanged ANSI 250 Bronze or Stainless TrimThree-way Valves available in Mixing or Diverting2½” to 6”ServiceChilled/hot water, 60% glycol, steam (G6C)Cv Range65-344 (Two-way) 68-340 (Three-way Mixing) 68-248 (Three-way Diverting)MaterialStainless steel stem, Bronze plug or Stainless plugControlOn/Off, Floating Point, 2-10 VDCMulti-Function Technology®Electronic Fail-Safe or Non-Spring ReturnElectronic G6…C(S), G7...(S) SeriesFlanged Globe Valves 2½” to 6”Installation Instructions3Flanged Globe Valves 2½” to 6”Installation InstructionsWarning!Valve should not be used for combustible gas applications. Gas leaks and explosions may result. Do not install in systems which exceed the ratings of the valve. • Avoid installations where valve may be exposed to excessive moisture, corrosive fumes, vibration, high ambient temperatures, elements, or high traffic areas with potential for mechanical damage. • Valve assembly location must be within ambient ratings of actuator. If the temperature is below -22°F, a heater is required. • The valve assembly will require heat shielding, thermal isolation, or cooling at the actuator if combined effect of medium and ambient temperatures (conduction, convection, and radiation) is above 122°F for prolonged time periods.• Strainers should be installed before coil and valve.• Visual access must be provided. Assembly must be accessible for routine service. Contractor should provide unions for removal from line and isolation valves.• Avoid excessive streses. Mechanical support must be provided where reducers have been used and the piping systems may have less structural integrity than full pipe sizes. • Vertical pipes with valves and dual actuators may require support for linkage.• Sufficient upstream and downstream piping runs must be provided to ensure proper valve capacity and flow response. Five diameters in each direction are reccomended. • Life span of the valve stems and packing is dependent on maintaining non-damaging conditions. Poor water treatment or filtration, corrosion, scale or other particulate can result in damage to trim components. A water treatment specialist should be consulted.1. Inspect shipping package, valve, linkage, and actuator for physical damage. If shipping damage has occurred, notify appropriate carrier. Do not install.2. If this is a replacement, remove the existing valve, linkage, and actuator from the piping system.3. If actuator and linkage are removed, they must be reinstalled correctly. The actuator must be rotated so that the valve seats properly for close-off. 4. Install valve with the proper ports as inlets and outlets. See piping charts on next page. Check that inlet and outlet of 2-way valves are correct; check that the “A”, “B”, and “AB” ports of 3-way valves are piped correctly. Flow direction arrows must be correct. 5. Blow out all piping and throughly clean below valve installation.6. clean male pipe threads with wire brush and rag. If threads have been damaged or exposed to weather, running a tap or die over the threads may straighten them. Clean pipes, threads, and valve threads before installation. Check for any foreign material that can become lodged in trim components. Strainers should be cleaned after initial startup.7. Pipe sealing compound may not be applied to either flange or gasket.8. Flanged bodies must be used with flanges which are rated for the service. 125 lb. flanges have flat faces and may not be bolted to raised face flanges. Gaskets rated for the medium and temperature-pressure must be used. 9. Valve must be installed with the stem towards the vertical, not below the horizontal.10. Tighten bolts alternatively and evenly around the flange.11. 2-way valve Normally Open (NO) or Normally Closed (NC) configurations must be verified by examining both the mechanical drawings and the valve and actuator.12. 3-way valve Normally Open (NO) or Normally Closed (NC) configurations for the control port and the bypass port must be verified by examining both the mechanical drawings and the valve and actuator. Check specifications for every application to be sure of ports and designations. U, L, and C designationsU is for Upper, the control port. L is for Lower, the bypass port. C is for Common.Viewed with the bonnet upwards ad the U port on the left, the L port is the bottom port, and the C is the right port. With the stem up, L is open to Common. With the stem down, U is open to Common.4Flanged Globe Valves 2½” to 6”Installation InstructionsFlow arrow shown on rear of valveFLOW PATTERN – Flow Pattern is Marked on ValveG6 2-way ValveStem Up = Open A to ABG7…D 3-way Diverting ValveStem Up = Open AB to BAABBG7 3-way Mixing ValveStem Up = Open B to ABABAB VALVE ASSEMBLY SET-UP - Specify Upon Ordering2-WAY VALVENON-SPRING RETURNSTAYS IN LAST POSITIONEV, RV SeriesNC: Normally closed A to AB, valve will open upon increase in signal/power.Note: To change valve to A to AB open, reverse the directional switch in actuator.NO: Normally open A to AB, valve will close upon increase in signal/power.Note: To change valve to A to AB closed, reverse the directional switch in actuator.SPRING RETURNNOTE FAIL POSITIONAFB, AFX SeriesOn/OffNO/FO: Normally open A to AB valve will drive closed. Spring Action: Will fail open A to AB upon power loss.NC/FC: Normally closed A to AB valve will drive open. Spring Action: Will fail closed A to AB upon power loss.AFB, AFX MFT SeriesNC/FO: Normally closed A to AB, valve will open upon increase in signal. Note: To change valve to A to AB open, reverse CW/CCW switch. Spring Action: Will fail open A to AB upon power loss.NO/FC or NC/FC: Normally Open/Normally Closed: valve can be open or closed, will drive closed or open A to AB (can be chosen with CW/CCW switch). Spring Action: Closed A to AB upon power loss.NO/FO: Normally open A to AB. Spring Action: Will fail open A to AB upon power loss. (NO or NC action can be chosen with CW/CCW switch).ELECTRONIC FAIL-SAFEAVK, GK SeriesNC/FO: Normally closed A to AB, valve will open upon increase in signal. Note: To change valve to A to AB open, reverse CW/CCW switch.Fail Position: Will default fail A to AB open, from the factory. Fail position can be set from 0%-100%, in 10% increments.NO/FC or NC/FC: Valve: Can be open or closed, will drive closed or open A to AB (can be chosen with CW/CCW switch). Fail Position: Will default fail A to AB open, from the factory. Fail position can be set from 0%-100%, in 10% increments.NO/FO: Normally open A to AB. Fail Position: Will default fail A to AB open, from the factory. Fail position can be set from 0%-100%, in 10% increments.3-WAY MIXING VALVENON-SPRING RETURNSTAYS IN LAST POSITIONEV, RV SeriesNC: Normally closed A to AB, will open upon increase in signal/power.Note: To change valve to A to AB open, reverse the directional switch in actuator.NO: Normally open A to AB, will close upon increase in signal/power.Note: To change valve to A to AB closed, reverse the directional switch in actuator.SPRING RETURNNOTE FAIL POSITIONAFB, AFX SeriesOn/OffNO/FO Normally open A to AB, valve will drive closed. Spring Action: Will fail open A to AB upon power loss.NC/FC Normally closed A to AB, valve will drive open. Spring Action: Will fail closed A to AB upon power loss.AFB, AFX MFT SeriesNC/FO Normally closed A to AB, valve will open upon increase in signal. Note: To change valve to A to AB open, reverse CW/CCW switch. Spring Action: Will fail open A to AB upon power loss.NO/FC or NC/FC Normally Open/Normally Closed: valve be open or closed, will drive closed or open A to AB (can be chosen with CW/CCW switch). Spring Action: Closed A to AB upon power loss.NO/FO Normally open A to AB. Spring Action: Will fail open A to AB upon power loss. (NO or NC action can be chosen with CW/CCW switch).ELECTRONIC FAIL-SAFEAVK, GK SeriesNC/FO Normally closed A to AB, valve will open upon increase in signal. Note: To change valve to A to AB open, reverse CW/CCW switch. Fail Position: Will default fail A to AB open, from the factory. Fail position can be set from 0%-100%, in 10% increments.NO/FC or NC/FC Valve: Can be open or closed, will drive closed or open A to AB (can be chosen with CW/CCW switch). Fail Position: Will default fail A to AB open, from the factory. Fail position can be set from 0%-100%, in 10% increments.NO/FO Normally open A to AB. Fail Position: Will default fail A to AB open, from the factory. Fail position can be set from 0%-100%, in 10% increments.3-WAY DIVERTING VALVENON-SPRING RETURNSTAYS IN LAST POSITIONEV, RV SeriesNC: Normally closed AB to B, will open upon increase in signal/power.Note: To change valve to AB to B open, reverse the directional switch in actuator.NO: Normally open AB to B, will close upon increase in signal/power.Note: To change valve to AB to B closed, reverse the directional switch in actuator.SPRING RETURNNOTE FAIL POSITIONAFB, AFX SeriesOn/OffNO/FO Normally open AB to B, valve will drive closed. Spring Action: Will fail open AB to B upon power loss.NC/FC Normally closed AB to B, valve will drive open. Spring Action: Will fail closed AB to B upon power loss.AFB, AFX MFT SeriesNC/FO Normally closed AB to B, valve will open upon increase in signal. Note: To change valve to AB to B open, reverse CW/CCW switch. Spring Action: Will fail open AB to B upon power loss.NO/FC or NC/FC Normally Open/Normally Closed: valve be open or closed, will drive closed or open AB to B (can be chosen with CW/CCW switch). Spring Action: Closed AB to B upon power loss.NO/FO Normally open AB to B. Spring Action: Will fail open AB to B upon power loss. (NO or NC action can be chosen with CW/CCW switch).ELECTRONIC FAIL-SAFEAVK, GK SeriesNC/FO Normally closed AB to B, valve will open upon increase in signal. Note: To change valve to AB to B open, reverse CW/CCW switch. Fail Position: Will default fail AB to B open, from the factory. Fail position can be set from 0%-100%, in 10% increments.NO/FC or NC/FC Valve: Can be open or closed, will drive closed or open AB to B (can be chosen with CW/CCW switch). Fail Position: Will default fail AB to B open, from the factory. Fail position can be set from 0%-100%, in 10% increments.NO/FO Normally open AB to B. Fail Position: Will default fail AB to B open, from the factory. Fail position can be set from 0%-100%, in 10% increments.5Mixing with Coil PumpSupplyReturnPumpCoilABBVBVABValve must be installed in these orientations only.2-WAYINSTALLATIONFlanged Globe Valves 2½” to 6”Piping Instructions3-WAY MIXING3-WAY DIVERTINGLinear ActuatorsUGLK Linkage6ANSI 125Flange Detail for American Standard 125 lb. Cast Iron Pipe FlangesFLANGESDRILLINGBOLTINGNominal Pipe SizeAFlange DiameterBFlange ThicknessCDiameter of Bolt CircleDDiameter of Bolt HolesNumberof BoltsDiameterof BoltsELength of Machine Bolts2½”7”¹¹⁄₁₆”5½”¾”4⁵⁄₈”2½”3”7½”¾”6”¾”4⁵⁄₈”2½”4”9”¹⁵⁄₁₆”7½”¾”8⁵⁄₈”3”5”10”¹⁵⁄₁₆”8½”⁷⁄₈”8¾”3”6”11”1”9½”⁷⁄₈”8¾”3¼”Flanged Globe Valves 2½” to 6”Installation InstructionsANSI 250Flange Detail for American Standard 250 lb. Cast Iron Pipe FlangesFLANGESDRILLINGBOLTINGNominal Pipe SizeAFlange DiameterBFlange ThicknessFDiameter of Raised FaceCDiameter of Bolt CircleDDiameter of Bolt HolesNumberof BoltsDiameterof BoltsELength of Machine Bolts2½”7½”1”4 ¹⁵⁄₁₆”5 ⁷⁄₈”⁷⁄₈”8¾”3¼”3”8¼”1¹⁄₈”5 ¹¹⁄₁₆”6 ⁵⁄₈”⁷⁄₈”8¾”3¼”4”10”1¼”6 ¹⁵⁄₁₆”7 ⁷⁄₈”⁷⁄₈”8¾”3¾”5”11”1 ³⁄₈”8 ⁵⁄₁₆”9 ¼”⁷⁄₈”8¾”4”6”12½”1⁷⁄₁₆”9 ¹¹⁄₁₆”10 ⁵⁄₈”⁷⁄₈”12¾”4”7WGVL/G6/G7 Linkage with EV and RV Series ActuatorsInstallation Instructions5m m1124AABBAABAAB171 2 54233125mm2!3!68Adaption121225 Nm5 NmSignal Direction8WGVL/G6/G7 Linkage with EV Series ActuatorsWiring DiagramsBLKBlackNegroNoirPretoREDRedRojoRougeVermelhoWHTWhiteBlancoBlancBrancoPNKPinkRosadoRosaCor-de rosORGOrangeAnaranjadoOrangeAlaranjadoBLUBlueAzulBleuAzulBRNBrownMarronBrunMarromNon-Spring Return Actuator with -3Non-Spring Return Actuator with -SR24 VAC TransformerBlk (1) - CommonRed (2) +Wht (3) +LineVolts2318Blk (1) CommonRed (2) + Wht (3) +LineVolts24 VAC Transformer2318Blk (1) CommonRed (2) + HotWht (3) Y1 Input, 2 to 10 VOrg (5) U Output, 2 to 10 V(–)(+)LineVolts24 VAC TransformerControl SignalVDC/mA31875001/4 WOn/OffFloating PointVDC / 4 to 20 mA100 to 240 VACBlu (1) CommonBrn (2) + Wht (3) +N L1H L2–LineHotA2Blk (1) CommonBrn (2) + Wht (3) +A2Line N L1Hot H L2100 to 240 VACSignalDirectionOn/OffFloating PointSelector SwitchesComLineVoltsHotController24 VAC Transformer (AC only)–Blk (1) CommonRed (2) + HotWht (3) Y1 Input224 VAC Transformer (AC only)LineVoltsHotControllerCom–Blk (1) CommonRed (2) + HotWht (3) Y1 Input2Triac SinkTriac SourceNon-Spring Return Actuator with MFTBlk (1) CommonRed (2) Hot Wht (3) Y InputOrg (5) U Output LineVolts24 VAC Transformer2 to 10 VDCFeedback Signal(+)(–)318LineVolts (–) (+)24 VAC TransformerBlk (1) – CommonRed (2) + HotWht (3) Y1 InputPnk (4) Y2 InputOrg (5) U OutputABABDirection of rotation switchABFeedback Signal 2 to 10 VDC21889Notes:On/OffFloating PointBlk (1) CommonRed (2) + HotWht (3) Y1 Input, 2 to 10 VOrg (5) U Output, 2 to 10 V(–)(+)LineVolts24 VAC TransformerControl SignalVDC/mA31875001/4 WFunctions0%50%100%Control mode acc. to YMinMidMaxNormalabc500Blk (1) CommonRed (2) + HotOrg (5)Wht (3) Y1 Input, 2 to 10 V(–)(+)LineVolts24 VAC Transformer (AC Only)BCA1/4 WVDC/mAControl Signal187VDC / 4 to 20 mAOverride Control Min, Mid, Max PositionsMeets cULus requirements without the need of an electrical ground connection.AActuators with appliance cables are numbered.2Actuators may be connected in parallel. Power consumption and input impedance must be observed.3Actuators may also be powered by 24 VDC.5Only connect common to neg. (-) leg of control circuits.7A 500 Ω resistor converts the 4 to 20 mA control signal to 2 to 10 VDC.8Control signal may be pulsed from either the Hot (Source) or Common (Sink) 24 VAC line.9Contact closures A & B also can be triacs. A & B should both be closed for the triac source and open for triac sink.10For triac sink the Common connection from the actuator must be connected to the Hot connection of the controller. Position feedback cannot be used with a triac sink controller. The actuator internal common reference is not compatible.12IN4004 or IN4007 diode. (IN4007 supplied, Belimo Part number 40155).18Actuators with plenum rated cable do not have numbers on wires; use color codes instead.9tomelhoanco-de rosoeranjadoulrromWGVL/G6/G7 Linkage with RV Series ActuatorsWiring DiagramsNon-Spring Return Actuator with -3 LineVolts24 VAC Transformer–Blk (1) CommonRed (2) + HotWht (3) Y1 Input21018812LineVolts24 VAC TransformerBlk (1) Common Red (2) Hot +Wht (3) Y1 InputABABDirection of rotation switchAB2101818188912SignalDirectionOn/OffFloating PointSelector SwitchesNon-Spring Return Actuator with MFTBlk (1) CommonRed (2) Hot Wht (3) Y InputOrg (5) U Output LineVolts24 VAC Transformer2 to 10 VDCFeedback Signal(+)(–)318LineVolts (–) (+)24 VAC TransformerBlk (1) – CommonRed (2) + HotWht (3) Y1 InputPnk (4) Y2 InputOrg (5) U OutputABABDirection of rotation switchABFeedback Signal 2 to 10 VDC21889Notes:On/OffFloating PointBlk (1) CommonRed (2) + HotWht (3) Y1 Input, 2 to 10 VOrg (5) U Output, 2 to 10 V(–)(+)LineVolts24 VAC TransformerControl SignalVDC/mA31875001/4 WFunctions0%50%100%Control mode acc. to YMinMidMaxNormalabc500Blk (1) CommonRed (2) + HotOrg (5)Wht (3) Y1 Input, 2 to 10 V(–)(+)LineVolts24 VAC Transformer (AC Only)BCA1/4 WVDC/mAControl Signal187VDC / 4 to 20 mAOverride Control Min, Mid, Max PositionsMeets cULus requirements without the need of an electrical ground connection.AActuators with appliance cables are numbered.2Actuators may be connected in parallel. Power consumption and input impedance must be observed.3Actuators may also be powered by 24 VDC.5Only connect common to neg. (-) leg of control circuits.7A 500 Ω resistor converts the 4 to 20 mA control signal to 2 to 10 VDC.8Control signal may be pulsed from either the Hot (Source) or Common (Sink) 24 VAC line.9Contact closures A & B also can be triacs. A & B should both be closed for the triac source and open for triac sink.10For triac sink the Common connection from the actuator must be connected to the Hot connection of the controller. Position feedback cannot be used with a triac sink controller. The actuator internal common reference is not compatible.12IN4004 or IN4007 diode. (IN4007 supplied, Belimo Part number 40155).18Actuators with plenum rated cable do not have numbers on wires; use color codes instead.BLKBlackNegroNoirPretoREDRedRojoRougeVermelhoWHTWhiteBlancoBlancBrancoPNKPinkRosadoRosaCor-de rosORGOrangeAnaranjadoOrangeAlaranjadoBLUBlueAzulBleuAzulBRNBrownMarronBrunMarromNext >