800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEAN16F6 Series 2-Way, Victaulic Butterfl y ValveTechnical DataServicechilled, hot water, 60% glycolFlow characteristicmodified equal percentageControllable flow range82°Sizes2” to 12”Type of end fittinggrooved ANSI/AWWA (C606)Valve materials*BodyBody finishDiscSeatShaftBearingductile iron ASTM A536, grade 65-45-12black alkyd enamelelectroless nickel coated ductile ironEPDM416 stainless steelfi berglass with TFE liningBody pressure rating300 psi Media temperature range-30°F to 250°F [-34°C to 120°C]Rangeability100:1Maximum close-off pressure200 psiMaximum velocity20 FPS*VIC®300 Masterseal™ as manufactured by Victaulic Company• 200 psi (2” to 12”) bubble tight shut-off• Long stem design allows for 2” insulation• Completely assembled and tested, ready for installationApplicationThese valves are designed to meet the needs of HVAC and commercial applications requiring bubble tight shut-off for liquids. Typical applicationsinclude chiller isolation, cooling tower isolation, change-over systems, largeair handler coil control, bypass and process control applications. The large values provide for an economical control valve solution for larger fl ow applications.Jobsite NoteValves should be stored in a weather protected area prior to construction.ValveSizeCv30°40°50°60°70°90°F650VIC2”115714236115F665VIC2-1/2”26016358140260F680VIC3”44026509140230440F6100VIC4”82051001625043820F6125VIC51200701402403706201200F6150VIC6”18001102203605609401800F6200VIC8”3400200410670105017703400F6250VIC10”5803570011501803020580F6300VIC12”9005401080178027904689002-waySuitable ActuatorsValveNominal SizeTypeSpring ReturnNon-Spring ReturnCv 90°Cv 60°INDN [mm]2-way11532”5F650VICAF SeriesAM SeriesSY Series2682½”6F665VICGM Series4401403”80F680VIC8202504100F6100VIC12003705”125F6125VIC18005606150F6150VIC3401050820F6200VIC5800180010”250F6250VIC9000279012”300F6300VIC50904 - 02/12 - Subject to change. © Belimo Aircontrols (USA), Inc.800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEAN17F6 Series 2-Way, Victaulic Butterfl y ValveMaximum Dimensions (Inches)ValveSizeCv 90°A(Max)B (Max)C (Max)D(Max)ActuatorClose-Off (PSI)F650VIC2”1153.212.008.6014.00AF…200pringeturnF665VIC2½”2603.772.008.6014.5050F665VIC2½”2603.778.608.6018.702*AF…200F680VIC34403.778.608.6018.7050F650VIC2”1153.214.708.0013.20AM...200Non-Spring ReturnF665VIC2½”2603.774.708.0013.6050F665VIC2½”2603.777.008.0014.00GM...200F680VIC34403.777.008.0014.305F6100VIC4”8204.638.608.0019.602*GM200F650VIC2”1153.213.202.4015.70SY1...200F665VIC2½”2603.773.202.4016.20200F680VIC34403.773.202.4016.4050F680VIC34403.774.609.2026.00SY2...200F6100VIC4”8204.634.609.2026.70200F6125VIC512005.884.609.2027.70SY2…/ SY3…50/200F6150VIC618005.884.609.2028.2050/200F6200VIC8”34005.337.3010.9033.30SY4…200F6250VIC10”58006.407.3010.9035.00SY4…/ SY5…50/200F6300VIC12”90006.507.3010.9036.00SY6…200†SY6 and larger available in 110/220 VAC versions only.SY... maximum actuator ambient temperature is 150°F.Application Notes1. Valves are rated at 200 psi differential pressure in the closed position2. 2-way assemblies are furnished assembled and tested, ready for installation.3. Dimension “D” allows for actuator removal without the need to remove thevalve from the pipe.4. Belimo SY Series actuators are NEMA 4X rated.5. Provide support for the actuator if it is mounted at any angle other than 90° vertical.6. Installer is to use rigid type couplings for connecting the valve to the piping.Pressure Drop - psi101010010001000010.10.012”/60.3 mm2 1/2”/73.0 mm & 76.1 mm3”/88.9 mm4”/114.3 mm & 108.0 mm5”/141.3 mm, 133.0 mm & 139.7 mm6”/168.3 mm &165.1 mm & 159.0 mm8”/219.1 mm10”/273.0 mm12”/323.9 mmADCBADC[162.38]6.393B[47.05]1.852[101.6]4[217.25]8.553[97.99]3.858Flow Rate (GPM)Dimensions50904 - 02/12 - Subject to change. © Belimo Aircontrols (USA), Inc.800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEAN64Dimensions with 2-Way ValveBHCAF Actuators, Multi-Function TechnologyModelsAFX24-MFT-X1AFX24-MFT-S-X1 w/built-in Aux. Switches2*AFX24-MFT-X12*AFX24-MFT-S-X1Dimensions (Inches)Fail Safe (psi)ValveSizeD(Max)BHCA2*AFF650HD2”1.659.009.0019.504.75200F650HDU2”1.659.009.0019.504.7550F665HD2½1.769.009.0020.005.5020F665HDU2½”1.769.009.0020.005.505F680HD31.789.009.0020.506.0050F680HDU31.789.009.0020.506.0050F6100HDU42.059.009.0021.007.5050F6125HDU5”2.149.009.0022.008.5050F650-150SHP2”1.759.009.0019.504.75150F665-150SHP2½”1.889.009.0020.005.50150F680-150SHP31.929.009.0020.506.00150F6100-150SHP2.139.009.0021.007.50150F650-300SHP2”1.759.009.0019.505.00150F665-300SHP2½”1.889.009.0020.005.88150F680-300SHP31.929.009.0020.506.63150F6100-300SHP42.139.009.0021.007.88150F665VIC2½”3.778.608.6018.70-200F680VIC33.778.608.6018.7050Dimensions with 3-Way ValveDABCDimensions (Inches)Fail Safe (psi)ValveSizeABD(Max)BHCA2*AFF750HD4.506.156.1515.504.75200F750HDU24.506.156.1515.504.7550F765HD½”5.006.766.7616.005.50200F765HDU2½”5.006.766.7616.005.5050F780HDU35.507.287.2816.256.0050 DWGP11Technical DataPower supply24 VAC, +/- 20%, 50/60 Hz24 VDC, +20% / -10%Powerrunning7.5 Wconsumptionholding3 WTransformer sizing10 VA (Class 2 power source)Electrical connectionft [1m] default, 10 ft [3m] or 16 ft [5m] 18 GA appliance or plenum cables, with or without 1/2” conduitconnector-S models: two 3ft [1m] default, 10 ft [3m] or 16 ft [5m] appliance cables with or without 1/2" conduitconnectorsOverload protectionelectronic throughout 0 to 95° rotationOperating range Y*2 to 10 VDC, 4 to 20 mA (default)variable (VDC, PWM, floating point, on/off)Input impedance100 kΩ for 2 to 10 VDC (0.1 mA)500Ωfor 4 to 20 mA 1500Ω for PWM, floating point and on/off controlFeedback output U*2 to 10 VDC, 0.5 mA maxTorqueminimum 180 in-lb (20 Nm)Direction ofspringreversible with cw/ccw mountingrotation*motorreversible with built-in switchMechanicalangle of rotation*95° (adjustable with mechanical end stop, 35° to 95°)Running timespring<20 sec @ -4°F to 122°F [-20° C to 50° C];<60 sec @ -22°F [-30° C]motor*150 seconds (default), variable (70 to 220 seconds)Angle of rotationadaptationoff (default)Override control*min position = 0%mid. position = 50%max. position = 100%Position indicationvisual indicator, 0° to 95°(0° is spring return position)Manual override5 mm hex crank (³⁄₁₆" Allen), suppliedHumiditymax. 95% RH, non-condensingAmbient temperature-22 to 122° F (-30 to 50° C)Storage temperature-40 to 176° F (-40 to 80° C)Housing NEMA 2, IP54, Enclosure Type 2Housing materialzinc coated metal and plastic casingNoise level40dB(A) motor @ 150 seconds, run time dependent62dB(A) spring returnAgency listings cULus acc. to UL60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EC & 2006/95/ECQuality standardISO 9001Servicingmaintenance freeWeight4.6 lbs. (1.9 kg), 4.9 lbs. (2 kg) with switch* Variable when configured with MFT options† Rated Impulse Voltage 800V, Type of action 1.AA (1.AA.B for -S version), Control Pollution Degree 3. Programmed for 70 sec motor run time. At 150 sec motor run time, transformer sizingis 8.5 VA and power consumption is 6 W running / 3 W holdingAFX24-MFT-S-X1Auxiliary switches2 x SPDT 3A (0.5A) @ 250 VAC, UL approvedone set at +10°, one adjustable 10° to 90°50904 - 02/12 - Subject to change. © Belimo Aircontrols (USA), Inc.800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEAN65Wiring DiagramsActuators may also be powered by 24 VDC.IN4004 or IN4007 diode (IN4007 supplied, Belimo part number 40155).Triac A and B can also be contact closures.Control signal may be pulsed from either the Hot (Source) orCommon (Sink) 24 VAC line.Position feedback cannot be used with Triac sink controller.The actuators internal common reference is not compatible.The ZG-R01 500 Ω resistor converts the 4 to 20 mA control signal to2 to 10 VDC, up to 2 actuators may be connected in parallel.Meets cULus or UL and CSA requirements without theneed of an electrical ground connection.WARNINGLive Electrical Components!During installation, testing, servicing and troubleshooting of this product, it maybe necessary to work with live electrical components. Have a qualifi ed licensed electricianor other individual who has been properly trained in handling live electrical componentsperform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury.AF Actuators, Multi-Function Technology399_ButterflyVDC/4-20 mA399_ButterflyPW399_ButterflyOn/Off controW399_ButterflyFloating Point controlAFB24-MFT-SAFX24-MFT-SAuxiliary Switches for AFX24-MFT-S-X1600_AFB_AFXAFX24-MFT-S-XBlk (1) CommonRed (2) + HotWht (3) Y Input, 2 to 10 VOrg (5) U Output 2 to 10 VCCW CWMasterCCW CWSlave24 VAC TransformerLine VoltsControl Signal 2 to 10 VDC (–)(+)35Blk (1) CommonRed (2) + HotWht (3) Y Input, 2 to 10 VOrg (5) U 5Master_SlaveMaster/Slave50904 - 02/12 - Subject to change. © Belimo Aircontrols (USA), Inc.Next >