Technical Data 1919 Fluidchilled or hot water, up to 60% glycol, steam Flow characteristicmodified equal percentage, unidirectional Controllable flow rangequarter turn, mechanically limited Valve Size [mm]2” [50] Pipe connectionASME/ANSI class 150 flange HousingCarbon steel full lug (ASME B16.34) Stem17-4 PH stainless steel SeatRPTFE Bearingglass backed PTFE Disc316 stainless steel Body Pressure RatingANSI Class 150 ANSI Class150 Number of Bolt Holes4 Lug threads5/8-11 UNC Maximum Inlet Pressure (Steam)50 psi Close-off pressure ∆ps285 psi Maximum Velocity32 FPS Cv102 Weight9.9 lb [4.5 kg] Fluid Temp Range (water)-22...400°F [-30...204°C] Leakage rate0% Servicingmaintenance-free Close-off pressures are variable and actuator dependent, consult Select Pro and/or Price Guide for specifics. Flow/Mounting Details 0 10 201030504060807090 20 30 40 60 50 70 80 100 90 100 % OF MA XI MU M FL OW % OF VALVE OPENING Application These valves are designed to meet the needs of HVAC and commercial applications requiring bubble tight shut-off for liquids. Typical applications include chiller isolation, cooling tower isolation, change-over systems, large air handler coil control, bypass and process control applications. The large Cv values provide for an economical control valve solution for larger flow applications. Product Features Double Dead End Service: Utilises larger retainer-ring setscrews to allow the valve to be placed at the end of the line without a down-stream flange in either flow direction at full pressure. The High Performance Butterfly Valve features a double offset (or, double eccentric) shaft design to minimize seat abrasion and lower torque. This double offset design allows the disc to lift off and come away from the seat as it rotates open. The face-to-face dimensions are API 609 & MSS-SP-68 compliant and are designed to be installed between ASME/ANSI B16.5 flanges. Every valve has a metal identification tag attached to the valve body. Information includes the figure number, the size and pressure class, the materials of construction, and the operating pressures and temperatures. Jobsite Note Valve assembly should be stored in a weather protected area prior to installation. Reference the butterfly valve installation instruction for additional information. Flow/Cv Cv 10°Cv 20°Cv 30°Cv 40°Cv 50°Cv 60°Cv 70°Cv 80°Cv 90° 1.5 6.1 14 26 39 56 77 99 102 Suitable Actuators Non-SpringSpringElectronic fail-safe F650-150SHPPRB(X), GMB(X)(2*AFB(X))PKRB(X), GKRB(X) Dimensions (Inches [mm]) 2*AF ABCDEF 17.6” [448]1.8” [45]17.2” [438]14.3” [363]2.9” [73] Safety Notes WARNING: This product can expose you to lead which is known to the State of California to cause cancer and reproductive harm. For more information go to www.p65warnings.ca.gov F650-150SHP Technical Data Sheet Reinforced Teflon Seat, 316 Stainless Steel 800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEAN Date created, 02/27/2020 - Subject to change. © Belimo Aircontrols (USA), Inc.Dimensions (Inches [mm]) GKB(X) ABCDEF 10.9” [277]1.8” [45]17.2” [438]12.5” [318]4.9” [124]4.9” [125] Dimensions (Inches [mm]) PKRB(X) ABCDEF 12.0” [304]1.8” [45]21.4” [544]16.8” [426]4.9” [124]4.9” [125] Dimensions (Inches [mm]) GMB(X) ABCDEF 9.1” [231]1.8” [45]13.0” [330]9.2” [234]3.9” [100] Dimensions (Inches [mm]) PRB(X) ABCDEF 12.0” [304]1.8” [45]17.4” [443]14.5” [368]2.9” [73] F650-150SHP Technical Data Sheet Reinforced Teflon Seat, 316 Stainless Steel 800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEAN Date created, 02/27/2020 - Subject to change. © Belimo Aircontrols (USA), Inc.Dimensions (Inches [mm]) GMB(X) N4 ABCDEF 14.1” [358]1.8” [45]19.0” [483]13.8” [350]5.2” [133] F650-150SHP Technical Data Sheet Reinforced Teflon Seat, 316 Stainless Steel 800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEAN Date created, 02/27/2020 - Subject to change. © Belimo Aircontrols (USA), Inc.Technical Data 2196 Power Supply24 VAC, ±20%, 50/60 Hz, 24 VDC, ±10% Power consumption in operation4.5 W Power consumption in rest position 1.5 W Transformer sizing7 VA (class 2 power source) Electrical Connection18 GA plenum cable, 3 ft [1 m], with 1/2” conduit connector (10 ft [3 m] and 15 ft [5 m] available) Overload Protectionelectronic throughout 0...95° rotation Operating Range2...10 V (default), 4...20 mA w/ ZG-R01 (500 Ω , 1/4 W resistor), variable (VDC, on/off, floating point) Operating range Y variableStart point 0.5...30 V End point 2.5...32 V Input Impedance100 k Ω for 2...10 V (0.1 mA), 500 Ω for 4...20 mA, 1500 Ω for PWM, On/Off and Floating point Position Feedback2...10 V, Max. 0.5 mA, VDC variable Angle of rotationMax. 95°, adjustable with mechanical stop Torque motor360 in-lb [40 Nm] Direction of motion motorselectable with switch 0/1 Position indicationMechanically, 30...65 mm stroke Manual overrideexternal push button Running Time (Motor)default 150 s, variable 90...150 s Ambient humiditymax. 95% r.H., non-condensing Ambient temperature-22...122°F [-30...50°C] Storage temperature-40...176°F [-40...80°C] Degree of ProtectionIP54, NEMA 2 Agency ListingcULus acc. to UL60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2014/30/EU and 2014/35/EU Noise level, motor45 dB(A) Servicingmaintenance-free Quality StandardISO 9001 Weight4.9 lb [2.2 kg] †Rated Impulse Voltage 800V, Type action 1, Control Pollution Degree 3. GMX24-MFT-X1 Technical Data Sheet Modulating, Non-Spring Return, 24 V, Multi-Function Technology® 800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEAN Date created, 04/03/2020 - Subject to change. © Belimo Aircontrols (USA), Inc.Wiring Diagrams INSTALLATION NOTES A Actuators with appliance cables are numbered. Provide overload protection and disconnect as required. Actuators may also be powered by 24 VDC. Only connect common to negative (-) leg of control circuits. A 500 Ω resistor (ZG-R01) converts the 4 to 20 mA control signal to 2 to 10 VDC. Control signal may be pulsed from either the Hot (Source) or Common (Sink) 24 VAC line. For triac sink the Common connection from the actuator must be connected to the Hot connection of the controller. Position feedback cannot be used with a triac sink controller; the actuator internal common reference is not compatible. IN4004 or IN4007 diode. (IN4007 supplied, Belimo part number 40155). 46 Actuators may be controlled in parallel. Current draw and input impedance must be observed. 47 Master-Slave wiring required for piggy-back applications. Feedback from Master to control input(s) of Slave(s). Meets cULus requirements without the need of an electrical ground connection. ! WARNING! LIVE ELECTRICAL COMPONENTS! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Blk (1) Red (2) Pnk (4) Wht (3) Org (5) Line Volts 24 VAC Transformer Position Feedback VDC (+) (–) Common + Hot Y 2 Input Y 1 Input U Output A 134647 On/Off 24 VAC Transformer (AC Only) Blk (1) Common Red (2) + Hot Wht (3) Y 1 Input Org (5) U Output Pnk (4) Y 2 Input Line Volts (–) (+) Position Feedback VDC 1104647 Floating Point Blk (1) Common Red (2) + Hot Pnk (4) Y 2 Input Wht (3) Y 1 Input Org (5) U Output (–) (+) Line Volts 24 VAC Transformer 500 1/4 watt Control Signal VDC / mA A 1354647 7 (+) Feedback VDC/mA Control Blk (1) Common Red (2) + Hot Wht (3) Y 1 Input Pnk (4) Y 2 Input Org (5) U Output Line Volts 24 VAC Transformer (AC only) (–) (+) Position Feedback VDC A 184647 PWM Control GMX24-MFT-X1 Technical Data Sheet Modulating, Non-Spring Return, 24 V, Multi-Function Technology® 800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEAN Date created, 04/03/2020 - Subject to change. © Belimo Aircontrols (USA), Inc. Functions 0% 50% 100% Control mode acc. to Y 1 Min Mid Max Normal abc Org (5) 24 VAC Transformer (AC Only) U Output 15 Blk (1) Common Red (2) + Hot Pnk (4) Wht (3) (–) (+) Line Volts B C A VDC / mA Control Signal Y 2 Input Y 1 Input 12 7 182 Override Control Blk (1) Common Red (2) + Hot Wht (3) Y 1 Input Org (5) U Output Master 24 VAC Transformer Line Volts Control Signal (–) (+) Blk (1) Common Red (2) + Hot Wht (3) Y 1 Input Org (5) U Output 154647 7 Slave 1 Master - Slave GMX24-MFT-X1 Technical Data Sheet Modulating, Non-Spring Return, 24 V, Multi-Function Technology® 800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEAN Date created, 04/03/2020 - Subject to change. © Belimo Aircontrols (USA), Inc.Next >