Technical Data 328371 Power Supply100...240 VAC, -15% / +10%, 50/60 Hz Power consumption in operation3 W Power consumption in rest position 0.5 W Transformer sizing7 VA (class 2 power source) Electrical Connection18 GA appliance cable, 3 ft [1 m], with 1/2” conduit connector Overload Protectionelectronic thoughout 0...90° rotation Angle of rotation90°, adjustable with mechanical stop Position indicationpointer Running Time (Motor)75 s Running time fail-safe<60 s Bridging time2 s delay before fail-safe activates Pre-charging time5...20 s Ambient humiditymax. 95% r.H., non-condensing Ambient temperature35...104°F [1.7...40°C] Storage temperature-40...176°F [-40...80°C] Degree of ProtectionIP40, NEMA 2 Housing materialUL94-5VA Agency ListingcULus acc. to UL60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2014/30/EU and 2014/35/EU Noise level, motor35 dB(A) Noise level, fail-safe35 dB(A) Servicingmaintenance-free Quality StandardISO 9001 Weight0.44 lb [0.20 kg] † Use flexible metal conduit. Push the listed conduit fitting device over the actuator’s cable to butt against the enclosure. Screw in conduit connector. Jacket the actuators input wiring with listed flexible conduit. Properly terminate the conduit in a suitable junction box. Rated impulse Voltage 800V. Type of action 1. Control pollution degree 3. Application Electronic Fail-Safe On/Off ZoneTight actuator. Valve selection should be done in accordance with the flow parameters and system specifications. The actuator is mounted directly to the valve without the need for tools or additional linkage. The actuator operates in response to AC 100...240 V. Angle of rotation is adjustable with the integrated mechanical stop. Safety Notes WARNING: This product can expose you to lead which is known to the State of California to cause cancer and reproductive harm. For more information go to www.p65warnings.ca.gov CQKBUP-RR Technical Data Sheet On/Off, Electronic Fail-Safe, AC 100...240 V 800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEAN Date created, 05/31/2020 - Subject to change. © Belimo Aircontrols (USA), Inc.Wiring Diagrams INSTALLATION NOTES A Actuators with appliance cables are numbered. Provide overload protection and disconnect as required. Actuators may be connected in parallel. Power consumption and input impedance must be observed. Meets cULus requirements without the need of an electrical ground connection. ! WARNING! LIVE ELECTRICAL COMPONENTS! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Blu (1) Neutral Brn (2) Load Blu N Brn L Line Volts 1 2 A 100 to 240 VAC FunctionsA 0% 100% 0%Fail PositionClose On/Off CQKBUP-RR Technical Data Sheet On/Off, Electronic Fail-Safe, AC 100...240 V 800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEAN Date created, 05/31/2020 - Subject to change. © Belimo Aircontrols (USA), Inc.Next >