Technical Data 318003 Mediachilled or hot water and steam Applicable Valve Size1/2” [13], 3/4” [19], 1” [25], 1-1/4” [32], 1-1/2” [38], 2” [50] HardwareSS and Nickel plated steel Frame, plate, basealuminum CouplingGF Nylon supplied Stroke0.6” [15 mm] LV, 3/4” [20 mm] SV Mounting Position360° Weight1.1 lb [0.50 kg] Media Temp Range (water)Please Refer to Manufacturer’s Valve Specifications For close-off pressure reference Select Pro or Retrofit Technical Documentation. Application The BGVL kit is designed to easily attach LV and SV series actuators to Belimo Globe Valves. The tapered bonnet and notched stem design allow easy installation of the BGVL on ½” to 2” two-way or three-way valves in both normally open and normally closed configurations. Operation The BGVL linkage with actuator will provide 20 mm of linear travel to accommodate a wide range of valve sizes. Default/Configuration The default set up for a BGVL linkage will be factory installed along with a LV or SV series actuator. Included in the kit will be all the necessary hardware to facilitate mounting to the Belimo Globe Valve. Suitable Actuators Non-SpringElectronic fail-safe BGVLLVB(X), SVB(X)LVKB(X), SVKB(X) Dimensions (Inches [mm]) C A B LVB, LVX, SVB, SVX ABC 6” [152]3.8” [97]7.9” [201] BGVL Belimo Globe Valve Linkage For Use with LV and SV Series Actuators 800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEAN Date created, 05/15/2019 - Subject to change. © Belimo Aircontrols (USA), Inc.Dimensions (Inches [mm]) BC A ABC 6.7” [171]3.8” [97]8.1” [206] BGVL Belimo Globe Valve Linkage For Use with LV and SV Series Actuators 800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEAN Date created, 05/15/2019 - Subject to change. © Belimo Aircontrols (USA), Inc.Technical Data 148104 Power Supply100...240 VAC, ±20%, 50/60 Hz Power consumption in operation2.5 W Power consumption in rest position 1.5 W Transformer sizing6 VA (class 2 power source) Electrical Connection18 GA appliance cable with 1/2” conduit connector, 3 ft [1 m], degree of protection NEMA 2 / IP54 Overload Protectionelectronic throughout full stroke Electrical Protectionactuators are double insulated Input Impedance100 k Ω (0.1 mA), 500 Ω , 1000 Ω (on/off) Position FeedbackNo Feedback Stroke0.75” [19 mm] Actuating force motor115 lbf [500 N] Direction of rotation motorreversible with switch Direction of motion fail-safereversible with switch Position indicationMechanically, with pointer Manual override4 mm hex crank (shipped w/actuator) Running Time (Motor)default 90 s, variable 90 or 150 s Bridging time2 s delay before fail-safe activates Pre-charging time5...20 s Ambient humiditymax. 95% r.H., non-condensing Ambient temperature-22...122°F [-30...50°C] Storage temperature-40...176°F [-40...80°C] Degree of ProtectionIP54, NEMA 2, UL Enclosure Type 2 Housing materialDie cast aluminium and plastic casing Agency ListingcULus acc. to UL60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EC and 2006/95/EC Noise level, motor55 dB(A) Noise level, fail-safe60 dB(A) Maintenancemaintenance-free Quality StandardISO 9001 Weight3.53 lb [1.6 kg] † Use flexible metal conduit. Push the listed conduit fitting device over the actuator’s cable to butt against the enclosure. Screw in conduit connector. Jacket the actuators input wiring with listed flexible conduit. Properly terminate the conduit in a suitable junction box. Rated impulse Voltage 800V. Type of action 1. Control pollution degree 3. †Rated Impulse Voltage 800V, Type of action 1.AA, Control Pollution Degree 3 Safety Notes WARNING: For Belimo products sold in California: these products do or may contain chemicals which are known to the State of California to cause cancer and or birth defects or other reproductive harms. For more information see www.p65warnings.ca.gov. LVKX120-3 Technical Data Sheet On/Off, Floating Point, Electronic Fail-Safe, Linear, 120 V 800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEAN Date created, 09/11/2019 - Subject to change. © Belimo Aircontrols (USA), Inc.Wiring Diagrams INSTALLATION NOTES A Actuators with appliance cables are numbered. Actuators may be connected in parallel. Power consumption and input impedance must be observed. Meets cULus requirements without the need of an electrical ground connection. ! WARNING! LIVE ELECTRICAL COMPONENTS! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Blu (1) Brn (2) + Wht (3) + Wht (4) 100 to 240 VAC N L1 H L2 Line Hot A 2 On/Off A Line N L1 Hot H L2 100 to 240 VAC Blu (1) Brn (2) Wht (3) Wht (4) + + + 2 Floating Point LVKX120-3 Technical Data Sheet On/Off, Floating Point, Electronic Fail-Safe, Linear, 120 V 800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEAN Date created, 09/11/2019 - Subject to change. © Belimo Aircontrols (USA), Inc.Next >