Technical Data148079Servicechilled, hot water, up to 60% glycolFlow Characteristicmodified linearControllable Flow Range75°Size [mm]2” [50]End FittingNPT female endsBodyforged brass, nickel platedBallchrome plated brassStemnickel plated brassSeatTeflon® PTFEBody Pressure Rating [psi]400Media Temperature Range (Water)0°F to 250°F [-18°C to 120°C]Max Differential Pressure (Water)50 psi (345 kPa)Close-Off Pressure200 psiCv87 Weight5.7 lb [2.6 kg]LeakageANSI Class VIServicingmaintenance freeFlow Pattern ApplicationThis valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some other common applications include Unit Ventilators, VAV box re-heat coils and bypass loops. This valve is suitable for use in a hydronic system with variable or constant flow.Suitable Actuators Non-SpringSpringB350LARB(X)AFRB(X)Dimensions (Inches [mm])H1EFBADCH2LRB, LRXABCDEFH1H29.91” [252]4.90” [124.5]7.7” [196]5.95” [152]1.73” [44]2.6” [66]0.75” [20]0.25” [12]B350L, 3-Way, Diverting Ball ValveChrome Plated Brass Ball and Nickel Plated Brass Stem800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEANDate created, 09/01/2016 - Subject to change. © Belimo Aircontrols (USA), Inc.Dimensions (Inches [mm])DBACEFAFRB, AFRXABCDEF11.27” [286]4.90” [124.5]8.36” [212]6.38” [162]2.6” [66]B350L, 3-Way, Diverting Ball ValveChrome Plated Brass Ball and Nickel Plated Brass Stem800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEANDate created, 09/01/2016 - Subject to change. © Belimo Aircontrols (USA), Inc.Technical Data100533Power Supply24...240 VAC +10% / -20%, 50/60 Hz, 24...125 VDC ±10%Power Consumption Running7 W Power Consumption Holding3.5 W Transformer Sizing7 VA @ 24 VAC (class 2 power source), 8.5 VA @ 120 VAC, 18 VA @ 240 VAC / heater 25 VA @ 120 VACElectrical Connection(2) 3ft [1m], 18 GA appliance cables with 1/2” conduit connectorsOverload Protectionelectronic throughout 0° to 95° rotationOperating Range Yon/offAngle of Rotation90°Direction of Rotation (Motor)reversible with CW/CCW mountingDirection of Rotation (Fail-Safe)reversible with CW/CCW mountingPosition Indicationvisual indicator, 0° to 95° (0° is full spring return position)Manual Override5 mm hex crank (3/16” Allen), suppliedRunning Time (Motor)<75 secRunning Time (Fail-Safe)<20 secAmbient Temperature Range-22°F to 122°F [-30°C to 50°C]Storage Temperature Range-40°F to 176°F [-40°C to 80°C]HousingNEMA 4, IP66, UL enclosure type 4Agency Listings†cULus acc. to UL60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EC and 2006/95/ECNoise Level (Motor)<45 dB (A) Noise Level (Fail-Safe)<62 dB (A) Servicingmaintenance freeQuality StandardISO 9001Auxiliary Switch2 x SPDT, 3A resistive (0.5A inductive) @ 250 VAC, one set at +10°, one adjustable 10° to 90°†Rated Impulse Voltage 800V, Type of action 1.AA, Control Pollution Degree 3AFRXUP-S N4NEMA 4, On/Off, Spring Return, 24 to 240 VAC800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEANDate created, 01/26/2017 - Subject to change. © Belimo Aircontrols (USA), Inc.Wiring DiagramsINSTALLATION NOTESAActuators with appliance cables are numbered.UPUniversal Power Supply (UP) models can be supplied with 24 VAC up to 240 VAC, or 24 VDC up to 125 VDC.Provide overload protection and disconnect as required.Two built-in auxiliary switches (2x SPDT), for end position indication, interlock control, fan startup, etc.45Actuators may be powered in parallel. Power consumption must be observed. 48Parallel wiring required for piggy-back applications.Apply only AC line voltage or only UL-Class 2 voltage to the terminals of auxiliary switches. Mixed or combined operation of line voltage/safety extra low voltage is not allowed.Meets cULus requirements without the need of an electrical ground connection.!WARNING! LIVE ELECTRICAL COMPONENTS!During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Wht (1)Blk (2)Wht NBlk LLine VoltsAUP14548NeutralLoad24 to 240 VACOn/Off 9041Auxiliary SwitchesAFRXUP-S N4NEMA 4, On/Off, Spring Return, 24 to 240 VAC800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEANDate created, 01/26/2017 - Subject to change. © Belimo Aircontrols (USA), Inc.Next >