Technical Data2087Servicechilled, hot water, up to 60% glycolFlow Characteristicequal percentageControllable Flow Range75°Size [mm]1.5” [40]End FittingNPT female endsBodyforged brass, nickel platedBallstainless steelStemstainless steelStem PackingEPDM (lubricated)SeatTeflon® PTFESeat O-ringEPDM (lubricated)Characterized DiscNo Disc (full flow)Body Pressure Rating [psi]400Media Temperature Range (Water)0°F to 250°F [-18°C to 120°C]Max Differential Pressure (Water)50 psi (345 kPa)Close-Off Pressure200 psiCv37 Weight2 lb [0.9 kg]Leakage0% for A to ABServicingmaintenance freeFlow PatternApplicationThis valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some other common applications include Unit Ventilators, VAV box re-heat coils and bypass loops. This valve is suitable for use in a hydronic system with variable flow.Suitable Actuators Non-SpringSpringB240ARB(X), NRQB(X)AFRB(X)Dimensions (Inches [mm])BACDH2EFH1ARB, ARXABCDEFH1H211” [279]3.88” [99]6.43” [163]5.28” [134]1.73” [44]1.18” [30]0.5” [15]B240, 2-Way, Characterized Control ValveStainless Steel Ball and Stem800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEANDate created, 10/27/2017 - Subject to change. © Belimo Aircontrols (USA), Inc.Dimensions (Inches [mm])BACDH2EFH1ARB, ARX 120-3, 120-SR, MFTABCDEFH1H211” [279]3.88” [99]6.43” [163]5.28” [134]1.73” [44]1.18” [30]0.5” [15]Dimensions (Inches [mm])B ACDEFAFRB N4, AFRX N4ABCDEF12.98” [330]3.88” [99]10.29” [261]8.55” [217]3.39” [86]Dimensions (Inches [mm])DH2CBAEFH1NRQB, NRQXABCDEFH1H211” [279]3.88” [99]7.12” [181]5.97” 152]1.73” [44]1.39” [34]0.5” [15]Dimensions (Inches [mm])B ACDEFARB N4, ARX N4, NRB N4, NRX N4ABCDEF11.36” [289]3.88” [99]8.47” [215]7.32” [186]3.15” [80]Dimensions (Inches [mm])BACDEFAFRB, AFRXABCDEF10.77” [274]3.88” [99]8.96” [228]7.81” [198]2.02” [51]B240, 2-Way, Characterized Control ValveStainless Steel Ball and Stem800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEANDate created, 10/27/2017 - Subject to change. © Belimo Aircontrols (USA), Inc.Technical Data2524Power Supply24 VAC, ±20%, 50/60 Hz, 24 VDC, ±10%Power Consumption Running3.5 WPower Consumption Holding1.3 WTransformer Sizing6 VA (class 2 power source)Electrical Connectionterminal blockOverload Protectionelectronic thoughout 0° to 90° rotationOperating Range Y2 to 10 VDC, 4 to 20 mA w/ ZG-R01 (500 Ω, 1/4 W resistor), variable (VDC, floating point, on/off)Input Impedance100 k Ω for 2 to 10 VDC (0.1 mA), 500 Ω for 4 to 20 mA, 1500 Ω for PWM, floating point and On/OffFeedback Output U2 to 10 VDC, 0.5 mA max, VDC variableAngle of Rotation90°Direction of Rotation (Motor)reversible with built-in switchPosition IndicationpointerManual Overrideunder coverRunning Time (Motor)150 secAmbient Temperature Range-22°F to 122°F [-30°C to 50°C]Storage Temperature Range-40°F to 176°F [-40°C to 80°C]HousingNEMA 4X, IP66/67, UL Enclosure Type 4Agency Listings†cULus acc. to UL60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/ECNoise Level (Motor)<45 dB (A) Servicingmaintenance freeQuality StandardISO 9001†Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 4.ARX24-MFT-T N4NEMA 4, Modulating Control, Non-Spring Return, Direct Coupled, 24 V, Multi-Function Technology®800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEANDate created, 11/30/2017 - Subject to change. © Belimo Aircontrols (USA), Inc.Wiring DiagramsINSTALLATION NOTESProvide overload protection and disconnect as required.Actuators may be connected in parallel. Power consumption and input impedance must be observed.Actuators may also be powered by 24 VDC.Only connect common to negative (-) leg of control circuits.A 500 Ω resistor (ZG-R01) converts the 4 to 20 mA control signal to 2 to 10 VDC.For triac sink the Common connection from the actuator must be connected to the Hot connection of the controller. Position feedback cannot be used with a triac sink controller; the actuator internal common reference is not compatible.IN4004 or IN4007 diode. (IN4007 supplied, Belimo part number 40155).16Actuators are provided with a numbered screw terminal strip instead of a cable.Meets cULus requirements without the need of an electrical ground connection.!WARNING! LIVE ELECTRICAL COMPONENTS!During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. (1) Common(2) + Hot (3) Y Input(5) U Output LineVoltsPositionFeedback VDC(+)(–)12163On/Off 24 VAC Transformer LineVolts (–) (+) (1) Common (2) + Hot (3) Y Input (5) U Output Position Feedback VDC 12121016Floating Point 24 VAC Transformer (AC Only) (1) Common (2) + Hot (3) Y1 Input (5) U Output(–)(+)LineVolts5001/4 wattControl SignalVDC/mAPositionFeedback VDC1235167VDC/mA Control 24 VAC Transformer Functions0%50%100%Control mode acc. to Y1MinMidMaxNormalabcOrg (5) 24 VAC Transformer (AC Only) U Output15Blk (1) CommonRed (2) + Hot Pnk (4) Wht (3) (–)(+)LineVoltsBCAVDC / mAControl Signal Y2 Input Y1 Input127162Override ControlARX24-MFT-T N4NEMA 4, Modulating Control, Non-Spring Return, Direct Coupled, 24 V, Multi-Function Technology®800-543-9038 USA866-805-7089 CANADA203-791-8396 LATIN AMERICA / CARIBBEANDate created, 11/30/2017 - Subject to change. © Belimo Aircontrols (USA), Inc.Next >