171908-00001.FQUICK MOUNT VISUAL INSTRUCTION MANUALPR and PKR Actuators with Butterfly Valves1i90°90°90°90°10 ... 15°09010 ... 15°10 ... 15°= 2 Way HD/L series shown2 Way HD/L series shownNear Field Communication (NFC) allows fast programming, commissioning and troubleshooting – even when the actuator is not powered it can be programmedBelimo Assistant AppSubject to change. © Belimo Aircontrols (USA), Inc.271908-00001.FQUICK MOUNT VISUAL INSTRUCTION MANUALPR and PKR Actuators with Butterfly Valves221343 09010132 x225 in-lb3 14202 Way HD/L seriesshown. Retrofitlinkages may vary.Subject to change. © Belimo Aircontrols (USA), Inc.71908-00001.F3QUICK MOUNT VISUAL INSTRUCTION MANUALPR and PKR Actuators with Butterfly Valves6№221 45 in-lb*2* Note: Use brass knockout toremove plastic if included with glandset. 3145 in-lb*2* Note: Use brass knockout toremove plastic if included with glandset. max. 3 ft-lbsO-ringPG11 Metric Thread1/2” NPT347654 - 6mm6 - 8mm8 - 10mm42134NEMA 4X 9 in-lb5№ 2123Subject to change. © Belimo Aircontrols (USA), Inc.471908-00001.FWIRING DIAGRAMSFloating PointPR and PKR Actuators End SwitchesTemp SensorVDC / 4 to 20 mABACnet24 to 240 VACor24 to 125 VDCN L Y1Y2 NComD +D -Com Bacnet D + D -Notes:0˚ to 90˚ default 85˚41!Meets cULus requirements without the need of an electrical ground connection. 5Only connect common to neg. (-) leg of control circuits.1Provide overload protection and disconnect as required.46Actuators may be controlled in parallel. Current draw and input impedance must be observed. 4Two built-in auxiliary switches (2x SPDT), for end position indication, interlock control, fan startup, etc.Universal Power Supply (UP) models can be suppliedwith 24 VAC up to 240 VAC, or 24 VDC up to 125 VDC. Optional: end switch adjustmentOn/OffN L Y1Y2 1UP46!Common + Hot Input CCW (open)Input CW (close)24 to 240 VAC or 24 to 125 VDCN L Y1Y2 1UP46!Common + Hot Input CCW (open)Input CW (close)24 to 240 VAC or 24 to 125 VDCN L Y1Y2 Common + Hot Input CCW (open)Input CW (close)24 to 240 VAC or 24 to 125 VDC1UP461!On/OffN L Y1Y2 N5UP4624 to 240 VACor 24 to 125 VDC-+ Y3U5Com -24 VDC Out Y3 0 - 10 VDC**U5/MP 0 - 10 VDC1**Control type, Direction and Fail position changes can be made via Belimo Assistant App, i.e. Floating or 4-20mA.!During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. PowerStatus56Push-buttons and displayBA123openopenS2S3S1S5S6S4S5S6S410°S2S3S5S6S4S5S6S4S1S2S3S4S5S64Disconnect power. 1 Gear disengagementOpen the manual override cover and insert the hand crank.Manual override is possible. Manual override2 Turn the hand crank until indicates the desired switching position and then remove the crank.AB3Auxiliary switchOpen the auxiliary switch adjustment cover and properly seat the hand crank into the actuator. Turn the crank until the arrow points to the vertical line.4 TerminalsConnect continuity tester to S4 + S5 or to S4 + S6.If the auxiliary switch should switch in the opposite direction, rotate the hand crank by 180˚.5 LED Display Green6 LED Display Yellow Off: No power supply or malfunction, On: In operation Press button: Triggers test run, followed by standard mode.6 LED Display YellowOff: Standard mode, On: Test run active.73 NEMA 4X12 in-lb21PowerWire separator4№ 2QUICK MOUNT VISUAL INSTRUCTION MANUALPR and PKR Actuators with Butterfly ValvesNext >