Accessories for HVAC/R Building Automation Products, Inc. • 750 North Royal Avenue, Gays Mills, WI 54631 USA Tel: +1-608-735-4800 • Fax: +1-608-735-4804 • Email: sales@bapihvac.com • Web: www.bapihvac.com F8 Power: 24VAC ±10% (If VDC power is required, call your BAPI rep.), 5 Amp Relays: 4 Watt / 4 VA max Rectification: Half Wave Wiring: Screw Terminals: 2 to 4 pair of 12 to 22AWG (BAPI recommends 16 to 22AWG). Water Detection Sensor: 2 wires (provided), optional Flex Connector or Liquid Tight Fitting for strain relief Sensor: Attached Sensor: Sensor w/ adjustable depth screw from 0.063 to 0.84” (1.60 to 21.34mm) Remote Sensor: Sensor w/ adjustable depth screw from 0.062 to 0.5” (1.57 to 12.70mm) (Attached and Remote Sensors are designed to be mounted to flat surfaces or on the rims of drip pans.) Latching and Supervised Relay Options: Latching.............Relays stay in alarm until manually reset or power is cycled Non-Latching.....Relays automatically reset after water is removed (default) Unsupervised.....Relays energize on water detection Supervised.........Relays de-energize on water detection (default) Note: Relay de-energizes on loss of power Reset Action: If latching, local pushbutton or power interrupt Local Indication: One green power LED, one red alarm LED Alarm Relay Contacts: LDT4: Two SPDT, 5 Amp relay outputs Operating Environment Remote Sensor: -4 to 158ºF (-20 to 70ºC), 0 to 100%RH, condensing Detector in BAPI-Box: -4 to 158ºF (-20 to 70ºC), 0 to 95%RH, non-condensing Enclosure Material and Ratings: NEMA 4 (IP66), UV-resistant polycarbonate, UL94 V-0 Agency: RoHS, UL Warranty: 5 years Features & Options Water Leak Detector – 5 Amp Relays ●Detection Within 5 Seconds with Local LED Alarm Indication ●Alarm Output, Two 5 Amp Relays ●Attached Sensor or Remote Sensor ●Automatic or Manual Unit Reset The Water Leak Detector is designed to sense the presence of water and alert a central monitoring system of the potentially destructive situation. Upon water detection, the alarm output relays change state, and a local red LED illuminates. The sensors detect dirty and purified water, deionized water, distilled water and reverse osmosis (RO) water. Specifications Remote Sensor Attached Sensor Rev. 01/31/22 Flex Connector Liquid Tight FittingAccessories for HVAC/R Building Automation Products, Inc. • 750 North Royal Avenue, Gays Mills, WI 54631 USA Tel: +1-608-735-4800 • Fax: +1-608-735-4804 • Email: sales@bapihvac.com • Web: www.bapihvac.com F9 Water Leak Detector – 5 Amp Relays BA/ ( #1 ) - ( #2 ) - ( #3 ) #1: Leak Detector Transmitter (required) LDT4 ...................Water leak detector with two 5A relays, SPDT contacts #2: Probe Sensor (required) PS.......................Probe Sensor built into the enclosure RS5.....................Remote Spot Sensor with 5 foot FEP cable RS10...................Remote Spot Sensor with 10 foot FEP cable RS25...................Remote Spot Sensor with 25 foot FEP cable #3: Enclosure and Fitting Options (required) BB......................BAPI-Box enclosure, IP66 rated BB-LTF...............BAPI-Box enclosure, IP66 rated, with liquid tight itting BB-GFF..............BAPI-Box enclosure, IP66 rated, with lex connector Example Number:BA/ ( LDT4 ) - ( RS10) - ( BB ) Actual Number (with parenthesis removed): BA/LDT4-RS10-BB Description: Detector with Two 5A Relays, 10’ Remote Sensor and BAPI-Box Enclosure Water Leak Detector Option Selection Guide Your Number: BA/ Part NumberSensor Type BA/RS5...............Remote Spot Water Sensor with 5 foot FEP cable BA/RS10.............Remote Spot Water Sensor with 10 foot FEP cable BA/RS25.............Remote Spot Water Sensor wtih 25 foot FEP cable Replacement Remote Sensors (For updates to existing systems) Unit with Attached Sensor Unit with Remote Sensor DimensionsNext >