AcuRev 1310 DIN Rail Power and Energy Meter | Datasheet | 1 Acuvim II |DatasheetDESCRIPTION AcuRev 1310 DIN Rail Power and Energy Meter Datasheet FEATURES +Utility Revenue Grade Accuracy: IEC 62053-22 0.5s Class / ANSI C12.20 0.5 Class +Integrated DIN rail channel for easy installation on standard, TS35 (35mm) DIN rail +10-690Vac direct voltage input accommodates all voltage rating systems with a single model + 4 channels of current input to capture neutral current measurements available in AcuRev 1314 model +Available compatibility with multiple CT output options including 5A, mA, RCT (Rogowski), or 333mV +Built-in RS-485 port with field-configurable Modbus RTU or BACnet MS/TP protocols for integration into most serial systems + Certified for revenue applications, the AcuRev 1310's tamper proof design is Measurement Canada approved. The AcuRev 1310 DIN Rail meter is engineered for high performance and easy integration into industrial or commercial facilities. Designed for cost-effective power and energy monitoring, it features a built-in LCD to simplify setup and provide quick access to metered data. Modbus-RTU and pulse output communications allow for seamless integration with data acquisition systems. C12.20 .5 CLASSKEY FEATURES Revenue Grade Certification + Meeting ANSI C12.20 Class 0.5 & IEC 62053-22 Class 0.5s accuracy standards, the AcuRev 1310 delivers revenue grade, high-precision data collection in building management systems and other metering applications. RMS measurements of voltage, current, power, frequency, and power factor are collected in real time. Measurement Canada Approved + The AcuRev 1310 meets stringent Measurement Canada requirements and its tamper-proof design is ideal for revenue applications. BTL Listed + The AcuRev 1310 is BTL Listed for Smart Sensor (B-SS) by the BACnet Testing Laboratory to ensure standard compliance, reliability, and interoperability in multi- vendor building automation and control systems. Universal Rating + Compatible with most voltage services without the need for a potential transformer (PT), the AcuRev 1310 can monitor a variety of electrical systems including three- phase three-wire, three-phase four-wire, single-phase, and more. Its four current input channels include neutral current measurement while Auto Phase-Check verifies installation integrity. SunSpec Compliance + To save installation time and cost within solar PV or energy storage applications, the AcuRev 1310 Modbus register list includes standard SunSpec registers to help ensure easy integration and plug-and-play system interoperability. APPLICATIONS + Energy Management Systems + Large Commercial Complexes + Industrial Environments + Hospitality & Hotels + Multi-Tenant Commercial or Residential + Schools & Universities + Smart Distribution CabinetsAcuRev 1310 DIN Rail Power and Energy Meter | Datasheet | 3 Acuvim II |DatasheetSPECIFICATIONS Metering PARAMETERSACCURACYRESOLUTIONRANGE Active Energy0.5% 1Wh0-999999999 Reactive Energy0.5% 1varh0-999999999 Apparent Energy0.5%1VAh0-999999999 Voltage0.5%0.110V-1000KV Current0.5%0.001A10mA-50000A Active Power0.5% 1W-99-99MW Reactive Power0.5% 1var-99-99Mvar Apparent Power0.5%1VA0-99MVA Power Factor0.5%0.001-1.000-1.000 Frequency0.2%0.01Hz45-65Hz Power Demand0.5% 1W/var/VA99MW/Mvar/MVA Current Demand0.5% 0.001A10mA-5000A Input CURRENT INPUTS (EACH CHANNEL) Nominal Current Options5A/1A Pickup Current10mA Accuracy0.50% VOLTAGE INPUTS (EACH CHANNEL) Nominal Full Scale400Vac L-N, 690Vac L-L Input Impedance2MΩ/Phase Metering Frequency50/60Hz Accuracy0.5% Full Scale ENERGY ACCURACY Active Class 0.5s (According to IEC 62053-22) Class 0.5 (According to ANSI C12.20) ReactiveClass 2 (According to IEC 62053-23) Communications RS-485 2-Wire Shielded Twisted Pair Connection 1200 to 34800bps PROTOCOLS Modbus-RTU BACnet-MS/TP INFRARED COMMUNICATION Non-contact infrared INFRARED BAUD RATE 1200ms I/O Options PULSE OUTPUT Isolation Voltage2500Vac Load Voltage0~250Vac Load Current100mA (max) RELAY OUTPUT (RO) Load Voltage Range250Vac, 30Vdc Load Current5A (Resistant Load) Opening Time10ms Isolation Voltage2000Vac for 1 minute Mechanical Life20 million times Electrical Life >50,000 times (5A, 250Vac, Resistant Load) Control Power AC/DC Control Power Operating Range100~415Vac, 50/60Hz, 100~300Vdc Power Consumption<2W Operating Environment Operating Temperature -25°C to 70°C -13°F to 158°F Storage Temperature -40°C to 85°C -40°F to 176°F Relative Humidity5% to 95% Non-Condensing Standard Compliance & Certifications Measurement Standard IEC 62053-22 0.5s class, ANSI C12.20 0.5 class Environmental StandardCE, RoHS Safety StandardIEC 61010-1, UL 61010-1 BTL BTL Listed for B-SS (AcuRev 1312, 1313, 1314)AcuRev 1310 DIN Rail Power and Energy Meter | Datasheet | 4 Acuvim II |DatasheetFUNCTION LIST Function1311131213131314 Feature Bi-Directional Energy Measurement Active Energy Reactive Energy Apparent Energy Time-of-Use Power Demand Peak Power Demand Predictive Demand Current Demand Peak Current Demand Voltage Current Neutral CurrentCalculatedCalculatedCalculated Residual CurrentCalculated Active Power Reactive Power Apparent Power Power Factor Frequency Clock Running Time Energy Pulse Output Relay Output (Alarm or Control) RS485 Modbus-RTU RS485 BACnet-MSTP Wiring Check Temperature (Internal) SunSpec Current Transformer (CT) Input 5A / 1A: Field-Configurable CT Input 333mV: CT Input RCT: Flexible Rogowski Coil CT Input 80/100/200mA: Field-Configurable CT Input I/O Options:One relay output for alarm and remote control Function; Option; Blank NA DIMENSIONS 3.54" (90.0mm) 1.40" (35.5mm)1.79" (45.4mm) 4.25" (108.0mm) 2.46" (62.5mm) 0.69" (17.5mm) 0.28" (7.0mm) 0.59" (15.0mm) Side ViewFront ViewAcuvim II |DatasheetWIRING DIAGRAMS Typical wiring for 5A/1A Current Input Typical Wiring for RCT/mV/mA Current Input 3LN, 3CT * 1A FUSE LOAD V N V3 V2 V1 AcuRev 1310 ABCN LINE 1191210 I11 I12 I21 I22 I31 I32 I41 I42 1 4 2 5 7 3 6 8 Terminal Block 1LL, 2CT LOAD LINE V N V3 V2 V1 AcuRev 1310 1191210 I11 I12 I21 I22 I31 I32 I41 I42 1 4 2 5 7 3 6 8 ANB1A FUSE 2LL, 2CT LOAD LINE V N V3 V2 V1 AcuRev 1310 1191210 I11 I12 I21 I22 I31 I32 I41 I42 1 4 2 5 7 3 6 8 ABC 1A FUSE 1LN, 1CT* 1A FUSE LOAD AN LINE V N V3 V2 V1 AcuRev 1310 1191210 I11 I12 I21 I22 I31 I32 I41 I42 1 4 2 5 7 3 6 8 Relay Output 220Vac R1 V+ LN com G R2 Relay Output Auxiliary Power Supply Auxiliary Power + Pulse + RS485 + – Va ux SS Pulse- Output (DO) Auxiliary Power RS485 L A N B /- S P1P2 Pulse Output100~415Vac, 50/60Hz 100~300Vdc AcuRev 1310 3LN, 3CT3LN, 3CT * 2LL, 3CT LINE LINE ABC ABC V N V3 V2 V1 AcuRev 1310 1191210 I11 I12 I21 I22 I31 I32 I41 I42 1 4 2 5 7 3 6 8 V N V3 V2 V1 AcuRev 1310 1191210 I11 I12 I21 I22 I31 I32 I41 I42 1 4 2 5 7 3 6 8 V N V3 V2 V1 AcuRev 1310 1191210 I11 I12 I21 I22 I31 I32 I41 I42 1 4 2 5 7 3 6 8 1A FUSE1A FUSE 1A FUSE ABCN LINE LOADLOADLOAD Terminal Block 1LL, 2CT* 1LN, 1CT * LINE ANB 1A FUSE LOAD V N V3 V2 V1 AcuRev 1310 1191210 I11 I12 I21 I22 I31 I32 I41 I42 1 4 2 5 7 3 6 8 LINE AN 1A FUSE LOAD V N V3 V2 V1 AcuRev 1310 1191210 I11 I12 I21 I22 I31 I32 I41 I42 1 4 2 5 7 3 6 8 Direct Connection, without PT’s Delta Connection *Neutral CT is optionalAcuRev 1310 DIN Rail Power and Energy Meter | Datasheet | 6 Acuvim II |DatasheetACCESSORIES USB RS485 Converter This professional-grade, plug-and-play USB to Serial RS485 Converter is compliant with both USB 1.1 and 2.0 standards and is designed to provide a convenient, reliable USB connection to the AcuRev 1310 Series meters and other serial devices. It requires no external power supply and provides both surge and static electricity protection. NEMA4X Wall-Mount Enclosure The AcuRev 1310 enclosure offers a mounting option for AcuRev 1310 Series energy meters that helps protect from tampering and the elements. The enclosure is NEMA4X rated to ensure durability and is equipped with DIN rail mounting hardware for easy meter installation. ORDERING INFORMATION Accessories (Optional) USB-RS485:RS485 to USB converter for connecting meter with computer, maximum distance 1200 meters. AcuRev 1310-ENC:NEMA 4X Enclosure Ordering Example: USB-RS485 + + Meter Model - Current Input - I/O AcuRev 13115A/1A: 5A/1A InputX0: No Additional I/O AcuRev 1312333: 333mV Input CTX1: 1 Relay Output AcuRev 1313RCT: AcuCT Flex Series Rogowski Coil Input AcuRev 1314mA: 80ma/100mA/200mA Ordering Example: AcuRev 1312-333-X1 Note: AcuRev 1314 does not support Rogowski coil input for neutral current. Consult Accuenergy Engineering Support for correct configuration. Accuenergy (Canada) Inc. Los Angeles - Toronto - Beijing - Pretoria North America Toll Free: 1-877-721-8908 Web: www.accuenergy.com Email: marketing@accuenergy.com Revision Date: May 2022 Version: 1.0.2 Specs Subject To Change Without Notice. ISO9001 CertifiedNext >