AcuSplitCT Series 075R Split Core Current Transformers The Accuenergy split core CTs are compact and low- cost current transformers with high accuracy. The CTs are ideal for quick and easy installation without disconnecting cables during installation. Multiple installation mechanisms provide stable and durable current measurement. DIMENSIONSSPECIFICATIONS Rated Primary CurrentUp to 150A Rated Output80mA, 100mA, 200mA, 333mV Withstand Voltage5,000Vac Operating Amb. Temperature-15°C to 65°C AccuracyIEC 60044-1 0.5s class Lead8 ft(2.5m) UL 1015 22AWG ConstructionUL enclosure rated to 135°C Certifications UL listed UL2808, 61010-1 and CSA 22.2 FEATURES n Multiple output including 80mA,100mA, 200mA, 333mV n Simple hinged installation n Can be installaed on cable, bus and panel n Standard Window size from 0.75 to 5 by 7 inch n Listed to UL2808, 61010-1 and CSA 22.2 SIZE CHART Dimensions (inch/mm) ABCDE 2.3/58.02.3/58.00.9/22.00.75/19.50.75/19.5 ORDERING INFORMATION Rated InputRated Output Ordering Number Ordering ExampleAcuCT-075R-50-333mV 50: 50A333mV 100: 100A80mA 150: 150A100mA 200mA Note: For any other size and ratio, please contact Accuenergy Corp. -- AcuCT-075R Accuenergy Corp. Los Angeles - Toronto - Beijing - Pretoria North America Toll Free: 1-877-721-8908 Web: www.accuenergy.com Email: marketing@accuenergy.com MAKE ENERGY USAGE SMARTER [ENERGY-MONITORING CT]AcuSplitCT Series 100R Split Core Current Transformers The Accuenergy split core CTs are compact and low- cost current transformers with high accuracy. The CTs are ideal for quick and easy installation without disconnecting cables during installation. Multiple installation mechanisms provide stable and durable current measurement. DIMENSIONSSPECIFICATIONS Rated Primary CurrentUp to 250A Rated Output1A, 80mA, 100mA, 200mA, 333mV Withstand Voltage5,000Vac Operating Amb. Temperature-15°C to 65°C AccuracyIEC 60044-1 0.5s class Lead8 ft(2.5m) UL 1015 22AWG ConstructionUL enclosure rated to 135°C Certifications UL listed UL2808, 61010-1 and CSA 22.2 FEATURES n Multiple output including 1A, 80mA,100mA, 200mA, 333mV n Simple hinged installation n Can be installaed on cable, bus and panel n Standard Window size from 0.75 to 5 by 7 inch n Listed to UL2808, 61010-1 and CSA 22.2 SIZE CHART Dimensions (inch/mm) ABCDE 2.6/65.02.6/65.00.9/22.01.0/25.01.0/25.0 ORDERING INFORMATION Rated InputRated Output Ordering Number Ordering Example AcuCT-100R-100-333mV 100: 100A1A 200: 200A333mV 250: 250A80mA 100mA 200mA Note: For any other size and ratio, please contact Accuenergy Corp. -- AcuCT-100R Accuenergy Corp. Los Angeles - Toronto - Beijing - Pretoria North America Toll Free: 1-877-721-8908 Web: www.accuenergy.com Email: marketing@accuenergy.com MAKE ENERGY USAGE SMARTER [ENERGY-MONITORING CT]AcuSplitCT Series 125R Split Core Current Transformers The Accuenergy split core CTs are compact and low- cost current transformers with high accuracy. The CTs are ideal for quick and easy installation without disconnecting cables during installation. Multiple installation mechanisms provide stable and durable current measurement. DIMENSIONSSPECIFICATIONS Rated Primary CurrentUp to 400A Rated Output1A, 80mA, 100mA, 200mA, 333mV Withstand Voltage5,000Vac Operating Amb. Temperature-15°C to 65°C AccuracyIEC 60044-1 0.5s class Lead8 ft(2.5m) UL 1015 22AWG ConstructionUL enclosure rated to 135°C Certifications UL listed UL2808, 61010-1 and CSA 22.2 FEATURES n Multiple output including 1A, 80mA,100mA, 200mA, 333mV n Simple hinged installation n Can be installaed on cable, bus and panel n Standard Window size from 0.75 to 5 by 7 inch n Listed to UL2808, 61010-1 and CSA 22.2 SIZE CHART Dimensions (inch/mm) ABCDE 3.2/82.03.2/82.00.9/22.01.25/32.01.25/32.0 ORDERING INFORMATION Rated InputRated Output Ordering Number Ordering Example AcuCT-125R-200-333mV 100: 100A1A 200: 200A333mV 300: 300A80mA 400: 400A100mA 200mA Note: For any other size and ratio, please contact Accuenergy Corp. -- AcuCT-125R Accuenergy Corp. Los Angeles - Toronto - Beijing - Pretoria North America Toll Free: 1-877-721-8908 Web: www.accuenergy.com Email: marketing@accuenergy.com MAKE ENERGY USAGE SMARTER [ENERGY-MONITORING CT]AcuSplitCT Series 200R Split Core Current Transformers The Accuenergy split core CTs are compact and low- cost current transformers with high accuracy. The CTs are ideal for quick and easy installation without disconnecting cables during installation. Multiple installation mechanisms provide stable and durable current measurement. DIMENSIONSSPECIFICATIONS Rated Primary CurrentUp to 1000A Rated Output1A, 80mA, 100mA, 200mA, 333mV Withstand Voltage5,000Vac Operating Amb. Temperature-15°C to 65°C AccuracyIEC 60044-1 0.5s class Lead8 ft(2.5m) UL 1015 22AWG ConstructionUL enclosure rated to 135°C Certifications UL listed UL2808, 61010-1 and CSA 22.2 FEATURES n Multiple output including 1A, 80mA,100mA, 200mA, 333mV n Simple hinged installation n Can be installaed on cable, bus and panel n Standard Window size from 0.75 to 5 by 7 inch n Listed to UL2808, 61010-1 and CSA 22.2 SIZE CHART Dimensions (inch/mm) ABCDE 4.4/111.04.4/111.01.25/32.02.0/51.02.0/51.0 ORDERING INFORMATION Rated InputRated Output Ordering Number Ordering Example AcuCT-200R-400-333mV 400: 400A1A 600: 600A333mV 800: 800A80mA 1000: 1000A100mA 200mA Note: For any other size and ratio, please contact Accuenergy Corp. -- AcuCT-200R Accuenergy Corp. Los Angeles - Toronto - Beijing - Pretoria North America Toll Free: 1-877-721-8908 Web: www.accuenergy.com Email: marketing@accuenergy.com MAKE ENERGY USAGE SMARTER [ENERGY-MONITORING CT]AcuSplitCT Series 3135R Split Core Current Transformers The Accuenergy split core CTs are compact and low- cost current transformers with high accuracy. The CTs are ideal for quick and easy installation without disconnecting cables during installation. Multiple installation mechanisms provide stable and durable current measurement. DIMENSIONSSPECIFICATIONS Rated Primary CurrentUp to 1500A Rated Output 5A, 1A, 80mA, 100mA, 200mA, 333mV Withstand Voltage5,000Vac Operating Amb. Temperature-15°C to 65°C AccuracyIEC 60044-1 0.5s class Lead8 ft(2.5m) UL 1015 22AWG ConstructionUL enclosure rated to 135°C Certifications UL listed UL2808, 61010-1 and CSA 22.2 FEATURES n Multiple output including 5A, 1A, 80mA, 100mA, 200mA, 333mV n Simple hinged installation n Can be installaed on cable, bus and panel n Standard Window size from 0.75 to 5 by 7 inch n Listed to UL2808, 61010-1 and CSA 22.2 SIZE CHART Dimensions (inch/mm) ABCDE 7/144.06.1/154.01.25/32.03.1/80.03.5/90.0 ORDERING INFORMATION Rated InputRated Output Ordering Number Ordering Example AcuCT-3135R-600-333mV 600: 600A1A 800: 800A5A 1000: 1000A333mV 1200: 1200A80mA 1500: 1500A100mA 200mA Note: For any other size and ratio, please contact Accuenergy Corp. -- AcuCT-3135R Accuenergy Corp. Los Angeles - Toronto - Beijing - Pretoria North America Toll Free: 1-877-721-8908 Web: www.accuenergy.com Email: marketing@accuenergy.com MAKE ENERGY USAGE SMARTER [ENERGY-MONITORING CT]AcuSplitCT Series 4161R Split Core Current Transformers The Accuenergy split core CTs are compact and low- cost current transformers with high accuracy. The CTs are ideal for quick and easy installation without disconnecting cables during installation. Multiple installation mechanisms provide stable and durable current measurement. DIMENSIONSSPECIFICATIONS Rated Primary CurrentUp to 5000A Rated Output 5A, 1A, 80mA, 100mA, 200mA, 333mV Withstand Voltage5,000Vac Operating Amb. Temperature-15°C to 65°C AccuracyIEC 60044-1 0.5s class Lead8 ft(2.5m) UL 1015 22AWG ConstructionUL enclosure rated to 135°C Certifications UL listed UL2808, 61010-1 and CSA 22.2 FEATURES n Multiple output including 5A, 1A, 80mA, 100mA, 200mA, 333mV n Simple hinged installation n Can be installaed on cable, bus and panel n Standard Window size from 0.75 to 5 by 7 inch n Listed to UL2808, 61010-1 and CSA 22.2 SIZE CHART Dimensions (inch/mm) ABCDE 7.3/185.09.3/235.01.8/45.04.1/105.06.1/155.0 Accuenergy Corp. Los Angeles - Toronto - Beijing - Pretoria North America Toll Free: 1-877-721-8908 Web: www.accuenergy.com Email: marketing@accuenergy.com MAKE ENERGY USAGE SMARTER ORDERING INFORMATION Rated InputRated Output Ordering Number Ordering Example AcuCT-4161R-1200-333mV 1200: 1200A1A 1600: 1600A5A 2000: 2000A333mV 3000: 3000A80mA 4000: 4000A100mA 5000: 5000A200mA Note: For any other size and ratio, please contact Accuenergy Corp. -- AcuCT-4161R [ENERGY-MONITORING CT]The Accuenergy split core CTs are compact and low- cost current transformers with high accuracy. The CTs are ideal for quick and easy installation without disconnecting cables during installation. Multiple installation mechanisms provide stable and durable current measurement. DIMENSIONSSPECIFICATIONS Rated Primary CurrentUp to 5000A Rated Output 5A, 1A, 80mA, 100mA, 200mA, 333mV Withstand Voltage5,000Vac Operating Amb. Temperature-15°C to 65°C AccuracyIEC 60044-1 0.5s class Lead8 ft(2.5m) UL 1015 22AWG ConstructionUL enclosure rated to 135°C Certifications UL listed UL2808, 61010-1 and CSA 22.2 SIZE CHART Dimensions (inch/mm) ABCDE 8.3/210.010.2/260.01.8/45.05.1/130.07.0/180.0 Accuenergy Corp. Los Angeles - Toronto - Beijing - Pretoria North America Toll Free: 1-877-721-8908 Web: www.accuenergy.com Email: marketing@accuenergy.com MAKE ENERGY USAGE SMARTER AcuSplitCT Series 5170R Split Core Current Transformers ORDERING INFORMATION Rated InputRated Output Ordering Number Ordering ExampleAcuCT-5170R-2000-333mV 2000: 2000A1A 3000: 3000A5A 4000: 4000A333mV 5000: 5000A80mA 100mA 200mA Note: For any other size and ratio, please contact Accuenergy Corp. -- AcuCT-5170R [ENERGY-MONITORING CT] FEATURES n Multiple output including 5A, 1A, 80mA, 100mA, 200mA, 333mV n Simple hinged installation n Can be installaed on cable, bus and panel n Standard Window size from 0.75 to 5 by 7 inch n Listed to UL2808, 61010-1 and CSA 22.2Next >