MINI-CONTACTORS - BA series Low Voltage Motor Control BA16 / BA251 8 4 3 7 7 5 1 6 1 2 3 4 5 6 7 8 -Compact contactor BA16 -Compact contactor BA25 -Auxiliary contact block HAXT - front mounting -Mechanical interlock block HA1NT -Easy connection busbars -Surge supressor blocks HSSRC (RC), HSSVR (varistor), HSSDO (diode) -Electronic timers HATMN, HATMF and HATMS -Block module for printed circuit board HAPCBK BA16 / BA25 2 3 3 6 6 7 IEC/EN 60947-5-1 Symbol Mechanically Linked Contacts IEC/EN 60947-4-1 Symbol Mirror Contacts Main Features Developed according to international standards IEC/EN 60947 (CE) and UL 508 (USA), they meet the requirements of a wide range of applications around the world. Ideal for applications where conventional contactors are too large for the space available and where streamlined projects are necessary. Although small, they are able to switch loads up to 690 V. They present high performance in electrical switching operations, reaching over one million operations. Positive Guided Contacts & Auxiliaries In order to meet the requirements of the safest and most demanding machine and equipment applications, the contactors were developed according to IEC/EN 60947-4-1 - Annex F, about “Mirror Contacts), and IEC/EN 60947-5-1 - Annex L, about “Mechanically Linked Contacts". Overview Low DC Coil Power Consumption L ow-consumption, direct current coils (4.0 W) enable the direct drive of the contactors via PLCs, inverter outputs or soft-starter, without using relay interfaces. Low-consumption coils allow to reduce power supplies, ensuring better use of the energy resources and lower costs on your electrical panel.AC coil - 50/60 Hz Coil voltage codesGACDEFH VAC - 50/60 Hz24120208/230347/380480600277 To Complete the Reference Code, Replace “♦” with the Appropriate Coil Voltage Code 2) Rated operational current I e AC-3 (U e ≤ 440 V) Conv. thermal current I th = I e AC-1 Max. rated operational power of single-phase motors 50/60 Hz Max. rated operational power of three-phase motors 50/60 Hz Auxiliary contacts per contactor 120 V HP 230 V HP 208 V HP 230 V HP 480 V HP 575 V HP 4 3 2 1 Part # AANONC 162212351010 10BA16-310-♦ 01 BA16-301-♦ 22321.5357.5151500BA25-300- ♦ Power Poles 4 3 2 1 NONC 162212351010 40BA16-400-♦ 22BA16-2200-♦ List $ Part #List $ Rated operational current I e AC-3 (U e ≤ 440 V) Max. rated operational power of single-phase motors 50/60 Hz Max. rated operational power of three-phase motors 50/60 Hz Conv. thermal current I th = I e AC-1 120 V HP 230 V HP 208 V HP 230 V HP 480 V HP 575 V HP BA16 / BA25 Contactors with screw terminals for AC-3 operation up to 22 A Compact contactor 16 A with the same size both for AC and DC coils Rated insulation voltage 690 V Significantly less consumption and heat dissipation, allowing PLC direct operation withoutcoupling relay Wide range of accessories, compact and fast mounting Designed according to the standards IEC 60947, UL 508 & CSA 22.2 #14 Power and auxiliary contacts comply with IEC 60947-4-1 (mirror contacts) and IEC 60947-5-1 (mechanically linked contacts) Terminalseasy to access and protected against accidental touch (IP20)Mounting through screws or DIN rail 35 mm Mini Contactors Rated operational current I e AC-3 (U e ≤ 440 V) Conv. thermal current I th = I e AC-1 Max. rated operational power of single-phase motors 50/60 Hz Max. rated operational power of three-phase motors 50/60 Hz1) Auxiliary contacts per contactor 120 V HP 230 V HP 208 V HP 230 V HP 480 V HP 575 V HP 4 3 2 1 AANONC 162212351010 10RBA16-310-♦ 01 RBA16-301-♦ Part #List $ $ 46 AC DC $ 46 $ 58NA $ 56 $ 56 $ 104 AC DC $ 104 $ 124 $ 124 $ 50 AC DC $ 50 $ 60 $ 60 Notes: 1) No reversing wires provided, see accessories page. Notes: 2) Other voltages available; DC coil - (BA16 Only) Coil voltage codesMNOPRI VDC122448110/12522072Normally Open Normally Closed Part # List 13 31 04 22 40 HAXT13 HAXT31 HAXT04 HAXT22 HAXT40 $ 26 $ 26 $ 26 $ 26 $ 26 Auxiliary Contact Blocks Top Mounted 10A Surge Suppressors ListPart Number 12 - 250 VDC 24 - 48 VAC 130 - 250 VAC Voltage Both On Delay, and Off delay timers available. Contact factory for part numbers and pricing Timers 400 - 510 VAC HSSD-250V HSSRC-48V HSSRC-250V HSSRC-510V $17 $17 $17 $17 HATM...$ 50 24 - 240V AC/DC ListPart NumberVoltage BA16 / BA25 Accessories Description Part # List HA1NT$ 18 Mechanical Interlock (BA16 only) •Front Mounting •Works with both AC and DC Coil Contactors •Can be mounted with the following Accessories Auxiliary Contact Blocks Surge Suppressor Timers Mechanical Interlock • 10A rated • Meets positive guided safety circuit standards 60947-5-1, and 60947-4-1 Used With BA16 BA25 22HAX5T22$ 26 Description Part # List HARKB16$ Reversing Wiring Kit (BA16 only) •One kit covers both Line and Load side. Reversing Wiring Kit Printed Circuit Board Kit •Allows mounting the BA16 contactor with screw terminals onto a printed circuit board. •Connectors made with metallic terminals with special coating for better adherence of the weld DescriptionListPart Number Kit includes two pieces, Line & Load side. HAPCBK $ 26Dimensions (mm) HAXT HSSRC HSSVR H SSDC HATMN HATMF HATMS HARKB16 HA1NT HAXT HSSRC HSSVR HSSDC DIN 35 mm 58 58 HATMN HATMF HATMS HSSRC H SSVR HSSDC HAX5T DIN 35 mm BA16 / BA25 10xØ2.3 Dimensions HAXT HSSRC HSSVR HSSDC DIN 35 mmGeneral Data Reference codeBA16BA25 StandardsIEC 60947 / UL 508 / CSA 22.2 #14 Rated insulation voltage U i (pollution degree 3) IEC/EN 60947-4-1, VDE 0660(V)690 UL, CSA(V)600 Rated impuse withstand voltage U imp (IEC/EN 60947-1) (kV)4 Rated operational frequency (Hz)25...400 Mechanical lifespan AC coill ps x 10 ”6” 103 DC coill ps x 10 ”6” 12- Electrical lifespan I e AC-33 ps x 10 ”6” 1.10.6 Degree of protection (VDE 0160) Main circuitsIP20 Control circuits and auxiliary contacts IP20 Mounting Screw or DIN rail 35 mm Coil terminals 2 Vibration resistance Contactor open(g)2 Contactor closed(g)4 Mechanical shock resistance (½ sinusoid = 11ms) Contactor open(g)6 Contactor closed (g)10 Ambient temperature Operation-25 °C ...+55 °C Storage-55 °C ... +80 °C Normal values Up to 3,000 m Altitude 90% I e / 80% U e 3,000 to 4,000 m 80% I e / 75% U e 4,000 to 5,000 m Control Circuit - Alternating Current (AC) Reference codeBA16BA25 Rated insulation voltage U i (pollution degree 3) IEC/EN 60947-4-1, VDE 0660(V)1,0001,000 UL, CSA(V)600600 Coils rated voltage 50 Hz (V)10...55010...550 Coils rated voltage 60 Hz (V) 12...66012...660 Coils rated voltage 50/60 Hz (V)12...66012...660 Coils rated voltage Coil operating limits (xUs)0.85...1.1 Coil 60 Hz Pick up(xUs)0.4...0.760.4...0.76 Drop out(xUs)0.25...0.650.25...0.65 Coil 50/60 Hz Pick up(xUs)0.5...0.80.5...0.8 Drop out(xUs)0.2...0.60.2...0.6 Average consumption 1.0 x Us coil cold state Coil 60 Hz Magnetic circuit closed(VA) 2.5...3.510.8....13.2 Power factor(cos ϕ )0.280.32 Power dissipation per pole(W)2.6- Magnetic circuit closing(VA)3572 Power factor(cos ϕ )0.850.93 Coil 50/60 Hz Magnetic circuit closed(VA)2...34.56...5.8 Magnetic circuit closing(VA)3058 Average time Closing NO contacts(ms)8...2013...16 Opening NO contacts (ms)6...1313.5...17 Reference code BA16 (3 pole) Coil type Conventional Rated insulation voltage U i (pollution degree 3) IEC/EN 60947-4-1, VDE 0660(V)1,000 UL, CSA(V)600 Standard voltages (V) 12...440 Coil operating limits (xUs)0.85...1.1 Pick up(xUs)0.4...0.7 Drop out(xUs)0.15...0.4 Power consumption 1.0 x Us coil cold state Magnetic circuit closed(W)2.6...3.7 Magnetic circuit closing(W)2.6...3.7 Operation time Closing NO contacts(ms)35...45 Opening NO contacts (ms)7...12 Control Circuit - Direct Current (DC) BA16 / BA25 Technical Data BA16 (4 pole) 2.9...4.0 2.9...4.0Power Circuit Reference code BA16BA25 Rated operational current I e AC-3 (U e ≤ 440 V) (A)1622 AC-4 (U e ≤ 440 V) (A)59 AC-1 ( θ ≤ 55 °C, U e ≤ 690 V) (A)2232 Rated operational voltage U e IEC/EN 60947-4-1, VDE 0660(V)690 UL, CSA1)(V)600 Rated thermal current I th (θ ≤ 55 °C) (A)2232 Making capacity - IEC/EN 60947 (A)160250 Breaking capacity IEC/EN 60947 (U e ≤400 V) (A)128200 (U e =500 V) (A)128200 (U e =690 V) (A)96150 Short-time current (no current flowing during recovery time of 10 min and θ ≤ 40 °C) 1 seg(A)250- 5 seg(A)125- 10 seg(A) 95- 30 seg(A)70- 1 min(A)50- 3 min(A)40- Protection against short-circuits with fuses (gL/gG) @600 V - UL/CSA 1) (kA)5 Coordination type 1(A)3550 Coordination type 2(A)2535 Average impedance per pole (mΩ)56 Average power dissipation per pole AC-1(W)2.46.1 AC-3(W)1.33.8 Utilization category Rated operational current I e ( θ ≤ 55 °C) U e ≤ 440 V (A)1622 U e ≤ 500 V (A) 1316 U e ≤ 690 V (A)1013 U e ≤ 1,000 V (A)Not available Rated operational power 220 / 230 V (kW)3.75.5 (cv)57.5 380 / V (kW)7.511 (cv)1015 400 / 415 V (kW)7.511 (cv)1015 440 V (kW)7.511 (cv) 1015 500 V (kW)7.511 (cv)1015 660 / 690 V (kW)7.511 (cv)1015 Max. electrical operational per hour 600 ops./h(%)100100 1,200 ops./h(%)7575 3,000 ops./h(%)5050 Utilization category AC-4 Rated operational current I e AC-4 (U e ≤ 440 V) (A)59 Rated operational power 1) (200,000 operations) 220 / 230 V (kW)1.12.2 (cv) 1.52.9 380 / 400 V (kW)2.24 (cv)2.95.4 415 V (kW)2.24.5 (cv)2.96 440 V (kW)2.24.5 (cv)2.96 500 V (kW)2.24.5 (cv)2.96 660 / 690 V (kW) 2.24.5 (cv)2.96 BA16 / BA25 Technical DataPower Circuit Reference code BA16BA25 Utilization category AC-1 3P (NO) or 4P (4NO)3P (NO) Rated thermal current I th (θ ≤ 55 °C)(A)2232 Maximum operational current (up to 690 V) θ ≤ 40 °C(A)2232 θ ≤ 55 °C(A)2232 θ ≤ 70 °C(A)17.625.6 Maximum operational power θ ≤ 55 °C 3-phase resistors 220 / 230 V(kW) 8.312 380 / 400 V(kW)14.521 415 / 440 V(kW)1623 500 V(kW)1826 660 / 690 V(kW)2536 Current values for connection of 2 poles in parallelI e x 1.7 3 poles in parallelI e x 2.4 4 poles in parallelI e x 3.2 Percentage of the max. operational current at 600 ops./h (%) 1001,200 ops./h (%) 3,000 ops./h (%) 2P (NO/NC) or 4P (2NO + 2NC)2P (NO/NC) Maximum operational power θ ≤ 55 °C (resistive load) 220 / 230 V(kW)4.86.6 380 / 400 V(kW)8.411.4 415 / 440 V(kW)9.212.5 500 V(kW) 10.514.5 660 / 690 V(kW)14.419.5 Built-In Auxiliary Contacts UL/CSA Power Ratings Reference code BA16 Standards IEC 60947-5-1, IEC 60947-4-1, UL 508, CSA 22.2 #14 Rated insulation voltage U i (pollution degree 3) IEC, VDE 0660(V) 690 UL, CSA(V) 600 Rated operational voltage U e IEC, VDE 0660(V)690 UL, CSA(V)600 Rated thermal current I th ( θ ≤ 55 °C)(A) 10 AC-15 (IEC 60947-5-1) U e ≤ 240 V(A)10 380-400 V(A) 6 415-440 V(A) 5 500 V(A)4 660-690 V(A)2 UL, CSAA600 DC-13 (IEC 60947-5-1) 24 V(A) 6 48 V(A) 4 110 V(A) 2 220 V(A) 0.7 UL, CSAQ600 Making capacity (rms)U e ≤ 400 V 50/60 Hz - AC-15(A) 10 x I e (AC-15) Breaking capacity (rms)U e ≤ 400 V 50/60 Hz - AC-15(A)10 x I e (AC-15) Control circuit reliability(V / mA) 17 / 5 Electrical endurance(millions operations) 1 Mechanical endurance(millions operations)10 Reference codeBA16BA25 General purpose current(600 V)2230 1-phase 110 / 120 V1 1 1/2 208 V2 3 220 / 240 V 2 3 3-phase 110 / 120 V2 3 200 V3 5 220 / 240 V5 7 1/2 440 / 480 V10 15 550 / 600 V10 15 BA16 / BA25 Technical Data (A) (HP) (HP) (HP) (HP) (HP) (HP) (HP) (HP)Reference code BA16 BA25 Screw typeM3x 8 Flat / Phillips M3.5x 9 Flat / Phillips Power terminal and built-in auxiliary terminal 1) Finely stranded with end sleeve Stranded and finely stranded without end sleeve Solid Finely stranded with end sleeve Stranded and finely stranded without end sleeve Solid mm² 1x 0.5...2.5 2x 0.5...1.5 1x 0.75...2.5 2x 0.75...2.5 1x 0.5...2.5 2x 0.5...2.5 1x 1...6 2x 1...2.5 2x 2.5...4 1x 1...6 2x 1...2.5 2x 2.5...6 1x 1...6 2x 1...2.5 2x 2.5...6 AWG (UL/CSA) 18...1218...10 Tightening torque (N.m)1.11.5 Tightening torque (lb.in) (UL/CSA) 1013 Reference codeBA09...BA16 / LH05 Screw type M3.5x 8 Flat / Phillips Coil terminals Finely stranded with end sleeveStranded , finely stranded without end sleeveSolid mm² 1x 0.5...2.5 2x 0.5...1.5 1x 0.75...2.5 2x 0.75...2.5 1x 0.5...2.5 2x 0.5...2.5 AWG (UL/CSA) 22...12 Tightening torque (N.m) 1.1 Tightening torque (lb.in) (UL/CSA) 10 Terminal Capacity and Tightening Torque - Power and Built-In Auxiliary Terminals Terminal Capacity and Tightening Torque - Coil Terminals Reference code StandardsIEC 60947-5-1, IEC 60947-4-1, UL 508, CSA 22.2 #14 Rated insulation voltage U i (pollution degree 3) IEC, VDE 0660(V)1,000 UL, CSA1)(V)600 Rated operational voltage U e IEC, VDE 0660(V)690 UL, CSA1)(V)600 Rated thermal current I th ( θ ≤ 55 °C) (A)10 Rated operational current I e AC-15 (IEC 60947-5-1) U e ≤ 240 V(A) 10 380-400 V(A)6 415-440 V(A) 6 500 V(A) 4 660-690 V(A)- UL, CSA1) A600 DC-13 (IEC 60947-5-1) 24 V(A)1.5 60 V(A)0.5 110 V(A)0.4 220-240 V(A)0.4 UL, CSA 1) Q600 Making capacity (rms) U e ≤ 400 V 50/60 Hz - AC-15(A)30 Breaking capacity (rms)U e ≤ 400 V 50/60 Hz - AC-15(A)3 Max.fuse class gL-gG without welding (short-circuit protection) (A)10 Control circuit reliability (V / mA)17 / 5 Electrical endurance (millions operations) 1 Mechanical endurance (millions operations)10 Screw type Auxiliary contact block Finely stranded with end sleeve Solid mm² 1x 0.5...2.5 2x 0.5...1.5 1x 0.5...4 2x 0.5...2.5 AWG (UL/CSA) Stranded and finely stranded without end sleeve 1x 0.75...4 2x 0.75...2.5 22...14 Tightening torque (N.m) 1.1 Tightening torque (lb.in) (UL/CSA) 10 Auxiliary Contact Blocks M3.5x9 Flat / Phillips BA16 / BA25 HAXT / HAX5TNext >