Automation Components, Inc. MISC. DEVICES | SM - 501 SMOKE DETECTOR MISC. DEVICES | ## Call: 1-888-967-5224 | Web: www.workaci.com SMOKE DETECTOR SM-501 The SM-501 series duct smoke detectors will provide early detection of smoke and products of combustion present in the air moving through a duct in any commercial, industrial, or residential application. These devices are designed for the prevention of smoke re-circulation by the air handling systems, fans, and blowers. The SM-501 is designed and built to meet all local requirements, as well as the NFPA regulations regarding duct smoke detectors. Output terminals are provided for remote accessories such as horns, strobes, remote status indicators, and test/reset key switches or pushbuttons. Air sampling is accomplished via two tubes that protrude into the duct. An exhaust tube with a standard length of 7" is supplied in the installation kit with the unit. Once the duct size is determined, a sampling tube must be ordered. Four standard sizes including a 1', 2.5', 5', and 10' lengths can be ordered and cut to the correct size of the duct. The SM-501 provides (2) sets of 10A Form "C" alarm contacts, along with (1) set of 10A Form "C" trouble contacts for monitoring head removal and supply voltage failure. The green pilot and red alarm indicators provided on the front of the SM-501 signal the operating status of the device. A manual test/reset switch is located next to the LED indicators. (Use part number SM-501-N for ionization and SM501-P for photoelectric). The ACI remote accessories are designed to be used with the ACI Duct Smoke detectors to provide audible and visual indication as well as remote test/rest functions. These devices mount to a standard single or double gang electrical backbox. Remote accessories are usually required by the AHJ (Inspector) for installation. If a duct smoke detector is not wired to a re system or a remote test station, when the unit goes into alarm, the end user would have to climb up to the duct to manually reset the unit. ACI oers two series of remote accessories, The MS Series and the MSR-50R Series. Applications: Smoke Detection in HVAC Ducts in Commercial, Industrial & Residential Applications The SM-501 Series is covered by ACI's Two (2) Year Limited Warranty, which is located in the front of ACI's Sensors & Transmitters catalog or can be found on ACI's website, which is: www.workaci.com. PRODUCT SPECIFICATIONS Supply Voltage: Maximum Operating Current (Standby): Maximum Operating Current (Alarm): Contact Form: Maximum Contact Switching Voltage: Maximum Contact Switching Current: Alarm Relays: Trouble Relays: Detection Head Type: Air Velocity: Wiring Connections: Conductor Size: Operating Temperature (SM-501-N): Operating Temperature (SM-501-P): Maximum Operating Humidity Range: Enclosure Material: Enclosure Base Finish: NEMA Rating: Hardware Included: Enclosure Product Dimensions: Product Weights: Agency Approvals: Radioactive Element: 24 VAC/VDC, 115 VAC, 230 VAC 24 VDC: 15 mA | 24 VAC: 35 mA | 115 VAC: 25 mA | 230 VAC: 12 mA 24 VDC: 56 mA | 24 VAC: 74 mA | 115 VAC: 32 mA | 230 VAC: 16 mA Form 1C (SPDT Contact) 115 VAC 10 Amps (Resistive) Two (2) One (1) Photoelectric or Ionization: See Ordering Grid on Back of Data Sheet 500 to 4,000 ft / minute Screw Terminal Blocks Solid or Stranded: #12 to #22 AWG 32ºF to 158ºF (0ºC to 70ºC) 32ºF to 140ºF (0ºC to 60ºC) 85 ±5 % RH (@32 ±2°C; 86 ±3.6°F) Non-Condensing / Non-Freezing 18 ga. Steel backbox, clear plastic cover (Makrolon 94V-0) Grey NEMA 1 7” exhaust tube, sampling tube end cap, mounting template & mounting hardware (L) 9.125” (231.8 mm) x (W) 7.25” (184.15 mm) x (H) 2.25” (57.15 mm) 3.5 lbs (1.59 kg) UL & CUL Listed (UL268A, UROX, UROX7), File # S2829 CSFM Listed (3240-1004:108) MEA Accepted (73-92-E; VOL. 26) For SM-501-N (Ionization) Americium 241; 0.9 Micro-Curie | Do not expose to corrosive atmospheresAutomation Components, Inc. MISC. DEVICES | SM - 501 SMOKE DETECTOR DIMENSIONAL DRAWING Front ViewRight ViewTop View MISC. DEVICES | ## Call: 1-888-967-5224 | Web: www.workaci.com 9.125” (231.8mm) 3.81” (96.65mm) 2.25” (57.15mm) 0.72” (18.29mm) 6.25” (158.75mm) 7.25” (184.15mm) STANDARD ORDERING Model # SM-501-N SM-501-P Item # 102954 102955 Smoke Detector Type Ionization Photoelectric -OR-Model # Example: 102954SM-501-N SAMPLING TUBE ORDERING Model # FAST TUBE STS-2.5 STS-5.0 STS-10.0 Item # 131201 102961 102962 102960 Description Package of (3) 24" Sections | Sectional sampling tube, quickly assembled to length & UL Sampling Tube for 6” to 2.5’ duct width Sampling Tube for 2.5’ to 5.0’ duct width Sampling Tube for 5.0’ to 10.0’ duct width -OR- Model # Example: 131201FAST TUBE ACCESSORIES ORDERING Model # WP-1 55000-225APO 55000-328APO TG-1000 Item # 132840 110913 131873 144246 Description Weatherproof Enclosure, NEMA type 3R Replacement Ionization Detector Head Replacement Photoelectric Detector Head Aerosol Test Gas -OR-Model # Example:11091355000-225APO Note*: See MS & MSR Series Data Sheets for Remote Wall Plate Accessories (usually required)Next >