Automation Components, Inc. MISC. DEVICES | SL - 2000 SMOKE DETECTOR MISC. DEVICES | ## Call: 1-888-967-5224 | Web: www.workaci.com SMOKE DETECTOR SL-2000 The SL-2000 series duct smoke detectors will provide early detection of smoke and products of combustion present in the air moving through HVAC ducts in any commercial, industrial, or residential application. These devices are designed for the prevention of smoke re-circulation by the air handling systems, fans, and blowers. The SL-2000 is designed and built to meet all local requirements, as well as the NFPA regulations, regarding duct smoke detectors. Output terminals are provided for remote accessories such as horns, strobes, remote status indicators, and test/reset key switches or pushbuttons. The Ionization and Photoelectric detector heads are interchangeable and air sampling is accomplished via two tubes that protrude into the duct. An exhaust tube with a standard length of 7" is supplied in the installation kit with the unit. Once the duct size is determined, a sampling tube should be ordered. Four standard sizes including a 1', 2.5', 5', and 10' lengths can be ordered and cut to the correct size of the duct. The SL-2000 provides two sets of 10A form "C" and one set of a 2A form "A" alarm contacts, along with one set of 10A form "C" trouble contacts for monitoring head removal and supply voltage failure. The ACI remote accessories are designed to be used with the ACI Duct Smoke detectors to provide audible and visual indication as well as remote test/rest functions. These devices mount to a standard single or double gang electrical backbox. Remote accessories are usually required by the AHJ (Inspector) for installation. If a duct smoke detector is not wired to a re system or a remote test station, when the unit goes into alarm, the end user would have to climb up to the duct to manually reset the unit. ACI oers two series of remote accessories, The MS Series and the MSR-50R Series. Applications: Smoke Detection in HVAC Ducts in Commercial, Industrial & Residential Applications The SL-2000 Series is covered by ACI's Two (2) Year Limited Warranty, which is located in the front of ACI's Sensors & Transmitters catalog or can be found on ACI's website, which is: www.workaci.com. PRODUCT SPECIFICATIONS Supply Voltage: Maximum Operating Current (Standby): Maximum Operating Current (Alarm): Alarm Relay Contacts: Trouble Relay Contacts: Detection Head Type: Air Velocity: Wiring Connections: Conductor Size: Operating Temperature (SL-2000-N): Operating Temperature (SL-2000-P): Maximum Operating Humidity Range: Enclosure Material: NEMA Rating: Hardware Included: Enclosure Product Dimensions: Product Weights: Agency Approvals: Radioactive Element: 24 VAC/VDC, 115 VAC, 230 VAC 24 VDC: 14 mA | 24 VAC: 55 mA | 115 VAC: 22 mA | 230 VAC: 12 mA 24 VDC: 68 mA | 24 VAC: 190 mA | 115 VAC: 32 mA | 230 VAC: 18 mA Resistive Load: 2 sets form “C” rated at 10 Amps @ 115 VAC Resistive Load: 1 set form “A” rated at 2 Amps Resistive Load: 1 set form “C” rated at 10 Amps @ 115 VAC Photoelectric or Ionization: See Ordering Grid on Back of Data Sheet 100 to 4,000 ft / minute Screw Terminal Blocks Solid or Stranded: #12 to #22 AWG 32ºF to 158ºF (0ºC to 70ºC) 32ºF to 140ºF (0ºC to 60ºC) 85 ±5 % RH (@32 ±2°C; 86 ±3.6°F) Non-Condensing / Non-Freezing Grey plastic backbox, clear plastic cover (Makrolon 94V-0) NEMA 1 7” exhaust tube, sampling tube end cap, mounting template, test magnet, & mounting hardware (L) 13.5” (342.9 mm) x (W) 4.5” (114.3 mm) x (H) 2.25” (57.15 mm) 2.5 lbs (1.13 kg) UL & CUL Listed (UL268A, UROX, UROX7) File # S2829 CSFM Listed (3240-1004:105) MEA Accepted (73-92-E; VOL. 27) For SL-2000-N (Ionization) Americium 241; 0.9 Micro-Curie | Do not expose to corrosive atmospheresAutomation Components, Inc. MISC. DEVICES | SL - 2000 SMOKE DETECTOR DIMENSIONAL DRAWING Front & Top ViewsRight View MISC. DEVICES | ## Call: 1-888-967-5224 | Web: www.workaci.com 14.05” (356.87mm) 13.60” (345.44mm) 14.60” (370.84mm) 4.60” (116.84mm) 2.31” (58.67mm) 3.41” (86.61mm) STANDARD ORDERING Model # SL-2000-N SL-2000-P Item # 105791 105792 Smoke Detector Type Ionization Photoelectric -OR-Model # Example:105791SL-2000-N SAMPLING TUBE ORDERING Model # FAST TUBE STN-1.0 STN-2.5 STN-5.0 STN-10.0 Item # 131201 111653 105793 105794 105795 Description Package of (3) 24" Sections | Sectional sampling tube, quickly assembled to length & UL Sampling Tube for 12” or less duct width Sampling Tube for 6” to 2.5’ duct width Sampling Tube for 2.5’ to 5.0’ duct width Sampling Tube for 5.0’ to 10.0’ duct width -OR-Model # Example:131201FAST TUBE ACCESSORIES ORDERING Model # WP-2000 ENCLOSURE 55000-225APO 55000-328APO TG-2000 Item # 106505 110913 131873 128407 Description Weatherproof Enclosure, NEMA type 3R Replacement Ionization Detector Head Replacement Photoelectric Detector Head Aerosol Test Gas -OR-Model # Example:11091355000-225APO Note*: See MS & MSR Series Data Sheets for Remote Wall Plate Accessories (usually required)Next >