PRODUCT SPECIFICATIONSRH Supply Voltage(Reverse Polarity Protected): RH Supply Current (VA): RH Output Load Resistance: RH Output Signal: RH Accuracy @ 77°F (25°C): RH Measurement Range:Operating RH Range: Operating Temperature Range:Storage Temperature Range: RH Stability | Repeatability | Sensitivity: RH Response Time (T63)RH Sensor Type: RH Transmitter Stabilization Time: RH Connections | Wire Size: RH Terminal Block Torque Rating: RH NIST Test Points: Platinum RTD (PTC) | Number Wires (Wire Colors): Platinum RTD Output @ 32°F (0°C): Platinum RTD Tolerance Class: Platinum RTD Din Standard:Temperature Coecient: Platinum RTD Stability:Lead Wire Length | Conductor Size:Insulation | Rating: Enclosure Specications (Material, Flammability, Temperature, NEMA/IP Rating): Sensing Tube Material | Filter Material: Sensing Tube Dimensions (Length x Diameter): Product Dimensions (L x W x D): Product Weight: Agency Approvals: 4-20 mA: 250 Ohm Load: 15 - 40 VDC / 18 - 28 VAC | 500 Ohm Load: 18 - 40 VDC / 18 - 28 VAC0-5 VDC: 12 - 40 VDC / 18 - 28 VAC | 0-10 VDC: 18 - 40 VDC / 18 - 28 VACVoltage Output: 8 mA maximum (0.32 VA) | Current Output: 24 mA maximum (0.83 VA) 4-20 mA: 700 Ohms maximum | 0-5 VDC or 0-10 VDC: 4K Ohms Minimum2-wire: 4 - 20 mA (Factory Default) | 3-wire: 0-5 or 0-10 VDC and 4 - 20 mA (Field Selectable)+/- 1% over 20% RH Range between 20 to 90% | +/- 2%, 3%, or 5% from 10 to 95%0-100%0 to 95% RH, non-condensing (Conformally Coated PCB’s)-40 to 140°F (-40 to 60°C)-40 to 149°F (-40 to 65°C)Less than 2% drift / 5 years | 0.5% RH | 0.1% RH20 Seconds TypicalCapacitive with Hydrophobic Filter30 Minutes (Recommended time before doing accuracy verication)Screw Terminal Blocks (Polarity Sensitive) | 16 (1.31 mm²) to 26 AWG (0.129 mm²)4.43 to 5.31 lb-in (0.5 to 0.6 Nm)Default Test Points: 3 Points (20%, 50% & 80%) or 5 Points (20%, 35%, 50%, 65% & 80%)1% NIST Test Points: 5 Points within selected 20% Range (ie. 30%-50% are 30, 35, 40, 45 & 50)RHx-100-2W Series: (Brown/Brown) & RHx-1K-2W Series: (Black/Black)RHx-100-3W Series: (Brown/Brown/Black) & RHx-1K-3W Series: (Black/Black/White)RHx-100-xW-D Series: 100 Ohms nominal | RHx-1K-xW-D Series: 1000 Ohms nominal+/-0.06% Class A | Tolerance Formula: +/-°C = (0.15°C + (0.002 * |t|) DIN EN 60751 (IEC 751)3850 ppm/ °C+/-0.03% after 1000 Hours @ 572°F (300°C)14” (35.6 cm) | 22 AWG (0.65 mm)Etched Teon (PTFE) Colored Leads | Mil Spec 16878/4 Type E“-EH” Enclosure: ABS Plastic; UL94-V0; -40 to 140°F (-40 to 60°C)“-4X” Enclosure: Polystyrene Plastic; UL94-V2; -40 to 158°F (-40 to 70°C); NEMA 4X (IP 66)“EH” Enclosure: 304 Series Stainless Steel | 304 Series Stainless Steel“-4X” Enclosure: Schedule 40 PVC (White) | Slotted PVC without lter“-EH” Models with Sintered Filters: 7.75” (196.85 mm) x 0.75” (19.05 mm)“-4X” Models: 7.20” (182.88 mm) x 0.840” (21.34 mm)See drawings on back of data sheetA/RHx-xx-xW-D Series: 1.22 lbs. (0.55 kg) | A/RHx-xx-xW-D-4X Series: 0.50 lbs. (0.227 kg)CE, RoHS2, WEEEAutomation Components, Inc.HUMIDITY | PLATINUM RTDS | RH DUCTRH DUCTRelative Humidity, Duct, Platinum RTDThe ACI Relative Humidity with Platinum RTD Duct Series utilizes a thermoset polymer capacitive sensing element with a factory tted hydrophobic lter to improve its moisture resistance. The sensing elements multilayer construction also provides excellent resistance in applications where dust, dirt, oils and common environmental chemicals are found. The RH duct sensors include on board DIP switches which allow the user to select the desired output signal and can be powered by AC or DC power sources. Each unit also contains 0%, 50%, and 100% test options to verify that the transmitter is both working and wired properly. Field calibration can be performed by using the increment and decrement calibration DIP switches without the need to replace the sensing element. These enhancements provide increased exibility and outstanding long-term reliability without the need to replace the sensors in the eld. Duct congurations feature a weatherproof Euro style enclosure with a gasketed cover and conformally coated circuit boards for increased moisture resistance in high humidity environments. The sensor is protected by a stainless-steel sintered lter. Three and Five-point NIST Calibration Certicates are available and must be ordered separately when placing your order.Applications: Humidication, Dehumidication, Supply / Discharge / Return Air, Economizers, Clean Rooms, Data Centers, Process Control, Schools, Hospitals, Oce BuildingsThe ACI RH Platinum RTDs Duct is covered by ACI's Five (5) Year Limited Warranty. The warranty can be found in the front of ACI's Sensors & Transmitters catalog, as well as on ACI's website, www.workaci.com.HUMIDITY | ## Call: 1-888-967-5224 | Web: www.workaci.com 4XEHAutomation Components, Inc.HUMIDITY | PLATINUM RTDS | RH DUCTDIMENSIONAL DRAWINGFront ViewRight ViewTop View4.30”(109.22mm)2.12” (53.72mm)7.94” (201.60mm)3.70” (93.98mm)2.55”(64.77mm)2.23” (56.71mm)7.19” (182.56Ø1.08”(27.50mm)Euro Enclosure [EH]NEMA 4X Enclosure [4X]A/CUSTOM ORDERINGA. Sensor Series No Selection RequiredB. Accuracy Select One (1)MODEL #A/D = Duct (Euro Enclosure) | D-4X (NEMA 4X Enclosure)---- = 4 to 20 mA (Default) | 010 = 0 to 10 VDC | 05 = 0 to 5 VDCE. Conguration Select One (1)F. Output Signal Select One (1)Model # Example:DE.2WD.1KC.RH2B.A/A.010F.NISTG.Note: Outputs are eld selectable between 4-20 mA, 0-5 VDC & 0-10 VDCRH1 = +/-1% (Specify a 20% Range between 20 to 90% RH)RH2 = +/-2% | RH3 = +/-3% | RH5 = +/-5%HUMIDITY | ## Call: 1-888-967-5224 | Web: www.workaci.com 100 = 100 Ohm Platinum RTD | 1K = 1K Ohm Platinum RTDC. Model Series Select One (1)2W = Two Wires | 3W = Three WiresD. Number of Wires Select One (1)---- = No NIST Certicate | NIST = NIST Certicate (Must Specify 1, 3 or 5 Points)G. NIST (Temperature) Select One (1)ACCESSORIES ORDERING [NIST]Model #NIST RH CERTDescriptionRH Calibration Certicate (Specify 3 Point or 5 Point NIST)Model # Example:NIST RH CERTNote: When ordering NIST certicates, please add an additional line item under the corresponding A/RHx-xx-D Model NumberACCESSORIES ORDERING Model #A/SINTERED FILTERDescription3/8” Sintered Filter for RH Duct/Stainless Plate/Remote ProbeModel # Example:A/SINTERED FILTERItem #143433Ø0.75”(19.05mm)Next >