Supply Voltage [Q5]: Supply Voltage [B5]: Fuse Protection: Supply Current | Power Consumption: Analog Output Signals [Q5 Only]: Maximum Load Impedance: Communication Protocols: Communication Baud Rates [Q5]: B5 Communication Baud Rates [B5]: Factory Calibration Range: Display: Keypad: Relays | Contact Type | Relay Contact Ratings: Relay Life Expectancy: Status LEDs: Buzzer: Sensor Warm Up Time: Sensor Type: Sensor Gas Types: Coverage Area | Mounting Height: Sensor Life Expectancy: Unit Shelf Life: Replacement Sensor Modules: Recommended Maintenance: Enclosure Specications (Material Type, Flammability, NEMA/IP Rating: Enclosure Knockouts: Operating Temperature | Humidity: Operating Atmospheric Pressure¹: Recommended Storage Temperature/Humidity: Wiring Connections | Wire Size: Communications Cable: Terminal Block Torque Rating: Automation Components, Inc. GAS | Q5 / B5 SERIES GAS | ## Call: 1-888-967-5224 | Web: www.workaci.com Q5 / B5 SERIES Toxic/Combustible Gas Transmitter The B5/Q5 Toxic/Combustible Gas Detectors use various sensing technologies to detect a wide assortment of gases. These units are housed in a NEMA 4X rated plastic enclosure that will meet the most stringent applications. All models feature an internal clock, LCD Display for displaying gas concentrations and setup, LED Status Indication, integral buzzer with three user congurable relays and a number of dierent communication protocols for use with one of our gas controllers or your building management system. Factory calibrated sensor module replacements are available and are easily replaced in the eld by removing two screws on the previous module. All units should be checked for proper functionality and calibration once the replacement sensor module is reinstalled and has had a chance to warm up. A user selectable password can be used to protect the system integrity. The Q5 can be used as a standalone gas detector or in conjunction with the Q4C, M-Controller or Q-Controllers using the proprietary RS-485 Optomux communication protocol. The B5 uses BACnet™ MSTP (RS485) protocol to communicate directly with a BAS. Calibration gases and a 0.2 to 1 liter/minute ow limiting gas regulator are not available through ACI. These should be purchased through your local gas supply company or on-line companies such as Portagas® (Praxair®, Inc.) or Mesa Specialty Gases®. ACI also oers a full line of horns and strobes that can be used with the Gas detectors or building management system to alert building occupants of an alarm condition. Refer to all applicable Federal, State, Provincial and Local Health and Safety laws and regulations before using these products. The Q5/B5-GENL can be ordered to monitor specic combustible gases such as Gasoline, Ethanol, Diesel or Jet fuel. Contact ACI for specic gases. Applications: Mechanical Rooms, Warehouses, Refrigeration Plants, Industrial Plants, Process Monitoring, Leak Detection, Parking Garages, Auto/Truck Maintenance Facilities, Oil and Gas Industry The Q5/B5 Series Gas Transmitters are covered by ACI's Two (2) Year Limited Warranty against defects in material and workmanship from the date of shipment with the exception of the Sensor Modules (Electrochemical/Toxic: Six Months and Catalytic/Combustible: One Year). The warranty can be found in the front of ACI's Sensors & Transmitters catalog, as well as on ACI's website, www.workaci.com. PRODUCT SPECIFICATIONS VDC Supply Voltage: 24 VDC nominal (+18 to 30 VDC) (AC Power must not be grounded) VAC Supply Voltage: 24 VAC nominal (+15 to 24 VAC, AC Power must not be grounded) VDC Supply Voltage: 24 VDC nominal (+18 to 30 VDC) (AC Power can be grounded or non-grounded) VAC Supply Voltage: 24 VAC nominal (+15 to 24 VAC, AC Power must not be grounded) 0.750A Polyswitch; (Resets after fault is cleared & power to circuit is removed) 0.3A maximum | 8.4 VA Analog: 4-20 mA, 1 to 5 VDC or 2 to 10 VDC (All Analog Output Signals require 4-Wires) 4-20 mA Output: 600 Ohms maximum | 1-5 VDC or 2-10 VDC: 3000 Ohms minimum Q5 Communication Protocols: RS-485 Modbus RTU / OptoMux (Proprietary QEL Controller Protocol) B5 Communication Protocols: RS-485 Serial BACnet MS/TP (Master and Slave; Default: Master) 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 76800 Bits/Second (Default: 4800) 9600, 19200, 38400, 76800 Bits/Second (Default: 38400) See Gas Sensor Selection & Specication Table on back of data sheet LCD Graphic Display with backlight (Displays: TWA, STEL and Concentration) Three Capacitive Touch sensing keys Three | SPDT (Form C) Dry Contacts | 1.0A max. @ 30 VDC or 0.3A max. @ 125 VAC (Resistive Loads) Mechanical: 50,000,000 operations minimum @ 36,000 operations/hour Electrical: 200,000 operations minimum @ rated load Two Green LEDs (Tx/Rx Communication Status); Three Red LEDs (Relays 1, 2, & 3) 80 dB at 3.94” (10 cm), 2700 Hz (3 Programmable Tones) 24 Hours (Allow 24 hours before calibrating sensor after installation) See Sensor Technology Type in Table on back of Product Data Sheet Combustible, Toxic Gases/Oxygen Sensor & Infrared See Gas Sensor Selection & Specication Table on back of data sheet Toxic/Electrochemical Sensors: 2 to 3 Years, typical; Oxygen/Hydrogen Sensors: 18 months, typical Combustible/Catalytic: 3 to 5 years, typical; CO 7 years, typical Electrochemical (Toxic) Sensors: 6 months from date of purchase Catalytic (Combustible) Sensors: 1 year from date of purchase See additional on-line Product Literature or Contact ACI Combustible Sensors: Accuracy & Bump test every 3 months or as required by Code Toxic Sensors: Accuracy & Bump test every 6 months or as required by Code Plastic Enclosure; Polycarbonate Lexan; UL94 V-0, NEMA 4, 4X, 12 and 13 (IP66) ¾” Knockouts (accepts ½” Conduit Fittings) See Sensor Selection & Specication Table on back of data sheet | 5 to 95% RH, non-condensing 14.696 psi (1.0132 bar) +/- 10% 32 to 68ºF (0 to 20ºC) | 5 to 95% RH, Non-Condensing De-pluggable Screw Terminal Blocks | 16 to 24 AWG (0.2047 to 1.301 mm) Shielded Twisted Pair Belden 9841 or Equivalent, 120 Ohms Input Impedance 0.37 ft-lb (0.502 Nm) Nominal Note: When installed @ > 3000’ above sea level, the gas transmitters must be veried for accuracy & re-calibrated as needed after installation Q5 B5Automation Components, Inc. GAS | Q5 / B5 SERIES GAS | ## Call: 1-888-967-5224 | Web: www.workaci.com PRODUCT SPECIFICATIONS continued RoHS, cETL Listed, Safety requirement for Electrical Equipment for Measurement, Control & Laboratory Use Part 1: CAN/CSA-22.2 No. 61010-1 Third Edition, Dated May 11, 2012; General Requirements UL 61010-1 Third Edition, Dated May 11, 2012 Q5C-CO & B5C-CO only: UL 2075 Gas & Vapor Detectors & Sensors (ETL Control# 4010204) 1.00 lbs. (0.454 kg) 5.91” (150 mm) x 3.54” (90 mm) x 2.56” (65 mm) SENSOR SELECTION AND SPECIFICATION Gas Span Code CH3CO-100L NH3-100P NH3-1000P ASH3-1P C6H6-100L C4H10-100L BUTAN-100L CO2-5000P CO2-5V CO2-20V CO2-100V CO-250P CO-1000P CL2-5P CLO2-2P B2H6-2P C2H4-100L ETO-20P GEH4-2P H2-1000P H2-2000P H2-100L HBR-30P HCL-30P HCN-50P H2S-25P H2S-100P CH4-100L CH3OH-100L NO-100P NO2-10P O2-25V O3-1P C5H12-100L PH3-1P PH3-5P C3H8-100L SiH4-50P SO2-6P GENL-100L Combustible • • • • • • • • • • • 100% LEL in % By Vol. 2.6 % N/A N/A N/A 1.3 % 1.8 % 1.9 % N/A N/A N/A N/A N/A N/A N/A N/A N/A 2.7 % N/A N/A N/A N/A 4.0 % N/A N/A N/A N/A N/A 5.0 % 6.7 % N/A N/A N/A N/A 1.4 % N/A N/A 2.1 % N/A N/A Toxic • • • • • • • • • • • • • • • • • • • • • • • • • Measurement Range 0 - 100% LEL 0 - 100 PPM 0 - 1000 PPM 0 - 1 PPM 0 - 100% LEL 0 - 100% LEL 0 - 100% LEL 0 - 5000 PPM 0 - 5% by Volume 0 - 20% Volume 0 - 100% Volume 0 - 250 PPM 0 - 1000 PPM 0 - 5 PPM 0 - 2 PPM 0 - 2 PPM 0 - 100% LEL 0 - 20 PPM 0 - 2 PPM 0 - 1000 PPM 0 - 2000 PPM 0 - 100% LEL 0 - 30 PPM 0 - 30 PPM 0 - 50 PPM 0 - 25 PPM 0 - 100 PPM 0 - 100% LEL 0 - 100% LEL 0 - 100 PPM 0 - 10 PPM 0 - 25% by Vol 0 - 1 PPM 0 - 100% LEL 0 - 1 PPM 0 - 5 PPM 0 – 100% LEL 0 - 50 PPM 0 - 6 PPM 0 - 100% LEL Square Feet ft (m) 5000 (464.5) 7500 (696.7) 7500 (696.7) 5000 (464.5) 5000 (464.5) 5000 (464.5) 5000 (464.5) 7500 (696.7) 7500 (696.7) 7500 (696.7) 7500 (696.7) 7500 (696.7) 7500 (696.7) 5000 (464.5) 5000 (464.5) 5000 (464.5) 5000 (464.5) 5000 (464.5) 5000 (464.5) 7500 (696.7) 7500 (696.7) 7500 (696.7) 5000 (464.5) 5000 (464.5) 5000 (464.5) 5000 (464.5) 5000 (464.5) 7500 (696.7 5000 (464.5) 7500 (696.7) 7500 (696.7) 7500 (696.7) 5000 (464.5) 5000 (464.5) 5000 (464.5) 5000 (464.5) 7500 (696.7) 5000 (464.5) 5000 (464.5) 5000 (464.5) Radius ft (m) 40 (12.2) 49 (14.9) 49 (14.9) 40 (12.2) 40 (12.2) 40 (12.2) 40 (12.2) 49 (14.9) 49 (14.9) 49 (14.9) 49 (14.9) 49 (14.9) 49 (14.9) 40 (12.2) 40 (12.2) 40 (12.2) 40 (12.2) 40 (12.2) 40 (12.2) 49 (14.9) 49 (14.9) 49 (14.9) 40 (12.2) 40 (12.2) 40 (12.2) 40 (12.2) 40 (12.2) 49 (14.9) 40 (12.2) 49 (14.9) 49 (14.9) 40 (12.2) 40 (12.2) 40 (12.2) 40 (12.2) 40 (12.2) 49 (14.9) 40 (12.2) 40 (12.2) 40 (12.2) Operating Temp ºF (ºC) 14 to 122 (-10 to 50) -22 to 122 (-30 to 50) -22 to 122 (-30 to 50) -4 to 104 (-20 to 40) 14 to 122 (-10 to 50) 14 to 122 (-10 to 50) 14 to 122 (-10 to 50) -4 to 122 (-20 to 50) -4 to 122 (-20 to 50) -4 to 122 (-20 to 50) -4 to 122 (-20 to 50) -4 to 122 (-20 to 50) -4 to 122 (-20 to 50) -4 to 122 (-20 to 50) -4 to 122 (-20 to 50) -4 to 104 (-20 to 40) 14 to 122 (-10 to 50) -4 to 122 (-20 to 50) -4 to 104 (-20 to 40) -4 to 122 (-20 to 50) -4 to 122 (-20 to 50) 14 to 122 (-10 to 50) -4 to 104 (-20 to 40) -4 to 122 (-20 to 50) -4 to 122 (-20 to 50) -4 to 122 (-20 to 50) 14 to 122 (-10 to 50) 14 to 122 (-10 to 50) 14 to 122 (-10 to 50) -4 to 122 (-20 to 50) -4 to 122 (-20 to 50) -22 to 122 (-30 to 50) -4 to 122 (-20 to 50) 14 to 122 (-10 to 50) -4 to 104 (-20 to 40) -4 to 104 (-20 to 40) 14 to 122 (-10 to 50) -4 to 104 (-20 to 40) -4 to 122 (-20 to 50) -40 to 122 (-40 to 50) Mounting Height Low High High Low Low Low Low Mid Mid Mid Mid Mid Mid Low Low Mid Mid Low Low High High High Low Mid Mid Low Low High Low Mid Low Mid High Low Low Low Low Mid Low Gas Dependent DIMENSIONAL DRAWING Front ViewRight ViewTop View Infrared Infrared Infrared Infrared Infrared Infrared Infrared Infrared Approvals: Product Weight: Product Dimensions (L x W x H): 5.91” (150mm) 3.54” (90mm) Ø.93” (23.62mm) 1.63” (41.40mm) 2.56” (65mm) 2.41” (61.21mm) 1.20” (30.48mm) Q5 & B5 Acetaldehyde, Benzene, Carbon Disulde, Dioxane, Ethane, Ethanol, Ethylbenze, Gasoline, Heptane, Hexane, Ipa, Isopropanol, Jet Fuel, Kerosene, Naphtha, Styrene, Toluene, Voc’s, Xylenes Specify Gas Gas Type Acetone Ammonia Ammonia Arsine Benzene Iso-Butane Butanol, n-Butane Carbon Dioxide Carbon Dioxide Carbon Dioxide Carbon Dioxide Carbon Monoxide Carbon Monoxide Chlorine Chlorine Dioxide Diborane Ethylene Ethylene Oxide Germane Hydrogen Hydrogen Hydrogen Hydrogen Bromide Hydrogen Chloride Hydrogen Cyanide Hydrogen Sulphide Hydrogen Sulphide Methane Methanol Nitric Oxide Nitrogen Dioxide Oxygen Ozone Iso-Pentane Phosphine Phosphine Propane Silane Sulphur Dioxide Combustibles Note : Lower Explosive Limit (LEL) | Note : Low = 0.5 to 1.5’ (0.15 to 0.46m) above oor | Mid = 4.0 to 6.0’ (1.20 to 1.83m) above oor | High = 0.5 to 1.5’ (0.15 to 0.46m) below ceiling Note : Oxygen sensors monitor oxygen depletion caused by numerous gases including: Nitrous Oxide, Helium, Nitrogen, Sulfur hexauoride, Argon, Xenon, Neon.Q5 = Toxic/Combustible Gas Transmitter Series with Analog/Relay/Communicating Output Signals and Display (All gases except CO) Q5C = Carbon Monoxide Toxic Gas Transmitter (Certied to meet UL 2075 Requirements for Carbon Monoxide (CO) only) B5 = Toxic/Combustible MS/TP BACnet™ Gas Detection Transmitter with Relays and LCD Display (All gases except CO) B5C = Carbon Monoxide MS/TP BACnet™ Toxic Gas Transmitter (Certied to meet UL 2075 Requirements for Carbon Monoxide (CO) only) A. Sensor Series Select One (1) C. Enclosure No Selection Required X = Factory Provided O = Standard Wall Mount Enclosure D. Revision No Selection Required X O Enter a “Gas Span Code” from the Sensor Selection & Specication Table B. Gas Span Code CUSTOM ORDERINGMODEL # Automation Components, Inc. GAS | Q5 / B5 SERIES GAS | ## Call: 1-888-967-5224 | Web: www.workaci.com ACCESSORIES ORDERING | Q5, B5 Model # 85930-006-000 85930-007-000 85930-040-000 GSG-1 Item # 128901 130812 131510 141059 Description Calibration Adaptor Kit for Q5/B5, Q6/B6 Sensor Splash Guard Kit for Q5/B5, Q6/B6 Duct Mount Kit (Adaptor, Tubing, Pitot Tubes) for Q5/B5, Q6/B6 Gas Sensor Protective Guard (White) -OR-Model # Example: 85930-006-000128901 STANDARD ORDERING Model # Q5C-CO-250P-O-X B5C-CO-250P-O-X Item # 141036 140654 Description CO, 0-250 ppm, UL2075 Certied BACnet™ CO, 0-250 ppm, UL2075 Certied -OR-Model # Example:141036Q5C-CO-250P-O-X Note: See Strobe & Alarm Data Sheet if required ACCESSORIES ORDERING | HORN STROBE Model # FSIG-SLM500A FSIG-SLM500B FSIG-SLM500G FSIG-SLM500R Item # 136476 142976 143013 143132 Description Streamline Horn and Strobe (Amber) Streamline Horn and Strobe (Blue) Streamline Horn and Strobe (Green) Streamline Horn and Strobe (Red) -OR-Model # Example: 136476FSIG-SLM500A ACCESSORIES ORDERING | MOUNTING BASE Model # FSIG-SLMBD-012-024GY FSIG-SLMBW-012-024GY Item # 142977 136477 Description Deep Base for FSIG-SLM500 Series; Gray Wall Mount Base for FSIG-SLM500 Series; Gray -OR-Model # Example:136477FSIG-SLMBW-012-024GY E. For GENL Sensors Enter a “Gas Type” from the Sensor Selection & Specication Table (See Combustibles) Model # Example: X D. O C. CO-250P B. B5C A.E.Next >