PRODUCT SPECIFICATIONSMonitored Current Type:Maximum AC Voltage:Operating Frequency Range:Core Style:Sensor Power:Amperage Range:Isolation Voltage:Trip Point Style | Adjustable Trip Point Range:Contact Type: “Status” Contact Rating:“Status” Contact “On” Resistance | “O” Resistance:Response Time: Aperture Size (Diameter):Operating Temperature Range:Operating Humidity Range:Recommended Storage Temperature | RH Range:Enclosure Material | Flammability Rating:Wiring Connections:Wire Size:Terminal Block Torque Rating:Minimum Mounting Distance:Agency Approvals:Product Weight:Product Dimensions (L x W x H):AC Current600 VAC 50/60 HzSolid-Core and Split-Core Versions available (See Ordering Grid)Induced from the Monitored Conductor (Insulated Conductors only) See Ordering Grid2200 VACFixed Trip Point | See Ordering Grid Normally-Open “N/O” 0.5A Continuous @ 36 VAC/VDC < 0.5 Ohms (tripped) | > 1 Meg Ohms (Open)A/MCS: < 50 mS typical | A/MSCS: < 40 mS typical0.53” (13.46 mm) -22 to 140ºF (-30 to 60ºC)0 to 95%, non-condensing41 to 95°F (5 to 35°C) | 40 to 85% RH, non-condensingPC/ABS (Polycarbonate/ABS Blend) | UL94-V02 Position Screw Terminal Block (Not Polarity Sensitive)16 to 22 AWG (1.31 mm to 0.33 mm) Copper Wires only4.43 to 5.31 in-lbs. (0.5 to 0.6 Nm)1” (2.6 cm) between current switch (Relays, Contactors, Transformers)UL/CUL US Listed (UL 916) Energy Management Equipment (File # E334792), CE, RoHS2, WEEEA/MCS: 0.15 lbs. (0.068 kg) | A/MSCS: 0.20 lbs. (0.091 kg)A/MCS (Solid-Core): 2.510” (63.82 mm) x 0.940” (23.94 mm) x 2.000” (50.80 mm)A/MSCS (Split-Core): 2.650” (67.19 mm) x 0.940” (23.94 mm) x 2.380” (60.49 mm)Automation Components, Inc.CURRENT | MINIATURE FIXED STATUSNote: Maximum wire length not to exceed 98.4 Feet (30 meters) in order to meet the CE RequirementsMINI FIXED STATUSMCS & MSCS SeriesThe Miniature Fixed Current Status” Switches are designed for use in any AC current monitoring application in which you are looking for a xed trip point to monitor the “Go/No Go” (On/O) ”Status” for a particular piece of equipment. The xed current switches should be installed on the line side of the power to the motor, pump, compressor or other equipment. All of the miniature current switches are available in both solid and split-core versions in a smaller enclosure style than that of the A/CS2 and A/SCS2 Series xed current switches rated for higher operating currents. The solid-core versions are a great choice for new installations or OEM applications in which cost sensitivity, lower trip points and environmental issues may be of concern. The split-core version of the current switches work great in retrot applications and for use in service vehicles since one part will work in most applications and can be installed without disconnecting any wires. Fixed status switches can also be used to determine the run time of your equipment when logging the contact closures on your building management system or PLC. Applications: On/O “Status” Indication, Local Alarms such as Strobes/Audible Alarms, Pumps, Fans, Compressors, Lighting Status and Usage Information, Ovens, Process Control, Industrial Equipment, OEM OpportunitiesThe Miniature Fixed Current “Status” Switches are covered by ACI's Five (5) Year Limited Warranty. The warranty can be found in the front of ACI's Sensors & Transmitters catalog, as well as on ACI's website, www.workaci.com.Split-CoreSolid-CoreCURRENT | ## Call: 1-888-967-5224 | Web: www.workaci.com DIMENSIONAL DRAWINGFront ViewRight ViewBottom ViewRevision C0000001 | Rev 1.0Automation Components, Inc.CURRENT | MINIATURE FIXED STATUS2.51” (63.82mm)1.99” (50.48mm)2.01” (51.05mm).99” (25.06mm)1.82” (46.14mm)2.38” (60.49mm)2.65” (67.19mm)2.15” (54.49mm).99” (25.06mm)Solid-CoreSplit-CoreSTANDARD ORDERINGModel #A/MCSA/MSCSItem #117852117853Trip Point TypeFixed Trip PointFixed Trip PointN/O••Solid-Core•Split-Core•Amp Range0 to 150A0 to 150ATrip Point0.20A or less0.55A or lessContact Rating1A @ 36 VAC/VDC1A @ 36 VAC/VDC-OR-Model # Example:117852CURRENT | ## Call: 1-888-967-5224 | Web: www.workaci.com A/MCSNote: The Miniature Fixed Current Switches are not intended to be used in Life / Safety Applications or in Hazardous / Classied LocationsNext >