Automation Components, Inc.ACCESSORIES | FREEZE STATSACCESSORIES | ## Call: 1-888-967-5224 | Web: www.workaci.com FREEZE STATSManual & Automatic with Relay(s)The FS Series are low limit controllers, also known as "Freeze Stats". These devices were designed for use on HVAC equipment that require low-temperature cutout protection to prevent cooling coils from freezing. They should be mounted between the heating and cooling coils on the supply side of the fan unit and respond to the lowest temperature sensed along any one foot section of the sensing element. The FS Series has manual and automatic reset versions, as well as, models that feature one or two sets of SPDT contacts. Numerous capillary lengths are also available.The ACI Freeze Stat is covered by ACI's Two (2) Year Limited Warranty. The warranty can be found in the front of ACI's Sensors & Transmitters catalog, as well as on ACI's website, www.workaci.com.PRODUCT SPECIFICATIONSThermostat Type:Sensing Element:Sensing Media: Sensing Temperature Operating Range: Sensing Capillary Overload Temperature:Sensing Response:Sensing Capillary Material: Sensing Capillary Installation: Sensing Capillary Length:Sensing Capillary Diameter:Type of Control: Low-Level Setpoint (Factory Set):Low-Level Setpoint Visual Range:Low-Level Setpoint Adjustment:Contact Form:# of Relays:Maximum Contact Switching Voltage:Maximum Contact Switching Current:Switching Dierential:Enclosure Operating Temperature Range:Operating Humidity Range:Storage Temperature Range: Enclosure Base Material: Enclosure Cover Material: Enclosure Color: Enclosure NEMA Rating:Cable Entry:Wire Connections:Maximum Wire Size:Agency Approvals:Product Weight:Enclosure Product Dimensions (L x W x H): Self-contained, electromechanicalVapor-lled capillaryTemperature in air14°F to 54°F (-10°C to 12°C)392°F (200°C), maximum 60 minutesTo lowest temperature sensed by any 1 ft section of the capillary elementCopperDuct and across coil mountedSee Ordering Grid on Back of Data SheetØ0.08 in. (2 mm) (6’ Length models have a larger bulb at the end)ON/OFF, low-level single-stage or cut-out control, with One (1) microswitch outputAt 39°F (4°C), and safety-lock secured14°F to 54°FOver full operating range, via screwdriver slotForm 1C (SPDT Contact)See Ordering Grid on Back of Data Sheet250 VAC15 (8) A1.8°F (1°K), auto- or manual reset14°F to 131°F (-10°C to 55°C)0 to 95% RH, non-condensing14°F to 158°F (-10°C to 70°C)Steel, galvanizedABS, re retardantSilver / Light GrayNEMA 1 (IP40)One (1) M20 compression tting, removable, hole ts 1/2 in. conduit connectorTerminal with wire-retaining screws14 AWG (2.5 mm²)CE 1.6 lbs (0.7 kg)4.1” (105 mm) x 3.3” (83 mm) x 2.1” (53 mm) Front ViewRight ViewTop ViewAutomation Components, Inc.ACCESSORIES | FREEZE STATSDIMENSIONAL DRAWINGACCESSORIES | ## Call: 1-888-967-5224 | Web: www.workaci.com 4.53”(115.01mm)Available with 6’, 10’, 20’ & 50’ Capillary Lengths4.53”(115.01mm)Ø0.375”(9.53mm)3.65”(92.71mm)4.35” (110.49mm)4.35” (110.49mm)2.18”(55.25mm)2.18”(55.25mm)STANDARD ORDERINGModel #FS-1FS-1AFS-2FS-2AFS-3FS-3AFS-4FS-4AFS-5FS-5AFS-6FS-6AFS-50FS-50AItem #102482102483102484105904106291106292106293106294106295106296106297106298142963142962Capillary Length20’ (6m)20’ (6m)20’ (6m)20’ (6m)10’ (3m)10’ (3m)10’ (3m)10’ (3m)6’ (1.8m)6’ (1.8m)6’ (1.8m)6’ (1.8m)50’ (16m)50’ (16m)# of Relays11221122112222Contact FormForm 1C (SPDT Contact)Form 1C (SPDT Contact)Form 1C (SPDT Contact)Form 1C (SPDT Contact)Form 1C (SPDT Contact)Form 1C (SPDT Contact)Form 1C (SPDT Contact)Form 1C (SPDT Contact)Form 1C (SPDT Contact)Form 1C (SPDT Contact)Form 1C (SPDT Contact)Form 1C (SPDT Contact)Form 1C (SPDT Contact)Form 1C (SPDT Contact)ResetManualAutoManualAutoManualAutoManualAutoManualAutoManualAutoManualAuto-OR-Model # Example:142962FS-50A ACCESSORIES ORDERINGModel #DBZ-05Item #108759DescriptionCapillary Mounting Clips (Set of 6)-OR-Model # Example:108759DBZ-05FS-1 FS-2FS-3FS-4 FS-50FS-5 FS-6Next >