Automation Components, Inc. INTERFACE | EFP EFP Floating Point to Pneumatic Output The EFP converts a oating point signal into a proportional pneumatic signal ranging from 0-20 psig. The pneumatic output is proportional to the signal input. The EFP* has a manual override switch with terminal strip contacts to indicate its status and a potentiometer to vary the pneumatic output. Two LEDs indicate UP or DOWN excursions, with an additional one for power indication. The EFP oers four jumper selectable rates of change in the output pressure. Output pressure ranges are jumper shunt selectable for 0 to 10, 0 to 15 and 0 to 20 psig, and adjustable in all ranges. A 0-5 VDC feedback signal, indicating the resultant branch line pressure, is also provided. This signal varies linearly with the branch pressure range selected. It is designed with electrical terminals on one end and pneumatic connections on the other, allowing for maximum convenience in wiring and tubing installation when panel mounted. The EFP is a constant bleed interface with branch exhaust response time determined by the bleed orice size and pressure dierentials. If power fails to the EFP, it will continue to bleed through the bleed orice until branch pressure is zero psig. The EFP2 incorporates two valves (one controls exhaust) and does not bleed air at set point. Its branch exhaust ow and response time are not limited by an internal restrictor and are similar to its load rate. If power fails to the EFP2, branch line pressure remains constant if the branch line does not leak air. The EFP2FS is a two valve fail safe model. Its three-way branch exhaust valve allows exhaust of branch line air on a power failure. Custom calibration is available upon request for an additional charge. Applications: 3 Way Mixing Valve Control, Chiller Loading, Pilot Positioner Control, Pneumatic Valve and Damper Actuator Control, Fan Vane Control, Compressor Staging The EFP is covered by ACI's Two (2) Year Limited Warranty. The warranty can be found in the front of ACI's Sensors & Transmitters catalog, as well as on ACI's website, www.workaci.com. Supply Voltage: Supply Current: Digital Input Signal Source: Digital Input Signal Level (@ Impedance): Digital Input Rates of Change: Manual / Auto Override Switch: Manual / Auto Override Feedback Output: Feedback Output Signal Range: Air Supply Pressure: Air Supply Consumption: Output Pressure Range (Jumper Selectable): Output Pressure Accuracy: Air Flow: Filtering: Connections | Wire Size: Terminal Block Torque Rating: Connections | Pneumatic Tubing Size-Type: Pneumatic Fitting: Gauge Pressure Range (Gauge Models): Gauge Pressure Accuracy (Gauge Models): Operating Temperature Range: Operating Humidity Range: Storage Temperature: Snaptrack Material: Snaptrack Flammability Rating: Product Dimensions: Product Weight: Agency Approvals: 24 VAC (+/-10%), 50 or 60Hz, 24 VDC (+10%/- 5%) 50 mA, 150 mA (3.6 VA) on pressure excursions, 180 mA (4.3 VA) on pressure excursions (FS model) Relay Contact Closure, Transistor or Triac 9-24 VAC/VDC @ 750 See Ordering Grid MAN function = output can be varied | AUTO function = output is controlled from input signal 24 VDC/VAC @ 1A maximum, N.O. in AUTO operation (Optional: N.O. in MAN operation) 0-5 VDC = Output Span Maximum 28 psig (193.06 kPa), minimum 22 psig (151.69 kPa) 750 SCIM (12.29 liters) 0-10 psig (0-68.95 kPa), 0-15 psig (0-103.43 kPa) or 0-20 psig (137.9 kPa) 2% full scale at room temperature (above 1 psig or 6.895 kPa) 3% full scale across operating temperature range (above 1 psig) Supply valves @ 20 psig (138 kPa) main/15 psig (103 kPa) out, 750 scim. Branch Line requires 2 in or 33.78 cm (minimum) | Min. 25 ft of 1/4” O.D. poly branch tubing Furnished with integral-in-barb 80-100 micron lter (Part # PN004) Optional standard barb (PN002) with external 5 micron in-line lter (PN021) 90° Pluggable Screw Terminal Blocks | 16 (1.31 mm) to 26 AWG (0.129 mm) 0.5 Nm (Minimum); 0.6 Nm (Maximum) 1/4" O.D. nominal (1/8” I.D.) polyethylene Removeable brass ttings for Main & Branch in machined manifold, Plugged 1/8-27-FNPT gauge port 0-30 psig (0-200 kPa) ± 2.5% Midscale (± 3.5% Full Scale) 35 to 120°F (1.7 to 48.9°C) 10 to 95% non-condensing -20 to 150°F (-28.9 to 65.5°C) Polyvinyl Chloride (PVC) UL94 V-0 No Gauge: (L) 4.00” (W) 3.25” (H) 1.87” (101.60 x 82.55 x 47.50 mm) WIth Gauge: (L) 4.00” (W) 3.25” (H) 2.95” (101.60 x 82.55 x 74.97 mm) EFPG: 0.596 lbs. (0.2703 Kg) | EFP2G: 0.76 lbs. (0.3459 Kg) | EFP2GF: 0.70 lbs. (0.3175 Kg) RoHS2, WEEE PRODUCT SPECIFICATIONS INTERFACE | ## Call: 1-888-967-5224 | Web: www.workaci.com Automation Components, Inc. INTERFACE | EFP ACCESSORIES Model # A/DO008 A/DRC 2.7 X 3.25 A/PN002 A/PN004 A/PN021 A/PN028 Item # 142583 142624 136499 110831 112219 128307 Description Transient Voltage Suppressor, Bi-directional, 56 VAC/DC, 1500W DIN Rail Adapter Kit 10-32 X 1/8" ID, Barb Fitting 80-100 Micron Filter Media in Barb Fitting In Line 10 Micron Filter, Installs in-between air supply and main barb connection Replacement Gauge -OR-Model # Example:142583A/DO008 STANDARD ORDERING Model # EFP EFPG EFP2 EFP2G EFP2G VERSION #2 EFP2FS EFP2GFS Item # 106319 106320 106321 106322 129480 106324 106323 Firmware Version # 0186Y1A.HEX 0186Y1A.HEX 0186Y1A.HEX 0186Y1A.HEX 0206Y0B.HEX 0186Y1A.HEX 0186Y1A.HEX Exhaust 41 SCIM (0.6719 Liters) 750 SCIM (12.29 Liters) 750 SCIM (12.29 Liters) 750 SCIM (12.29 Liters) 750 SCIM (12.29 Liters) 750 SCIM (12.29 Liters) 750 SCIM (12.29 Liters) Input Pulse Range 45s, 90s, 1 min, 2 min 45s, 90s, 1 min, 2 min 45s, 90s, 1 min, 2 min 45s, 90s, 1 min, 2 min 30s, 3 min, 6 min, 8 min 45s, 90s, 1 min, 2 min 45s, 90s, 1 min, 2 min Gauge • • • • Additional Information 0.007” Bleed Orice 0.007” Bleed Orice Maintains Branch Pressure Maintains Branch Pressure Maintains Branch Pressure Exhausts on Power Failure Exhausts on Power Failure -OR-Model # Example:106319EFP INTERFACE | ## Call: 1-888-967-5224 | Web: www.workaci.com 2.95” (74.93mm) Ø1.64” (41.66mm) 0.70” (17.78mm) DIMENSIONAL DRAWING Board OnlySnap TrackSnap Track EFP Board with Snap TrackBoard with Snap TrackBoard with Snap Track EFP With Gauge 4.00” (101.60mm) 3.25” (82.55mm) 3.25” (82.55mm) 4.00” (101.60mm) 3.25” (82.55mm) 2.70” (68.58mm)Next >