PRODUCT SPECIFICATIONSRelay Type:Nominal Relay Coil Voltage | Rated Current:Contact Form:Relay Contact Rating:Maximum Contact Switching Voltage:Maximum Contact Switching Current:Status LED Indication :Electrical Life (Relay):Mechanical Life (Relay):Din Rail Size:Operating Temperature Range:Operating Humidity Range:Storage Temperature | Humidity Range:Enclosure Material | Flammability Rating:Wiring Connections:Conductor Size:Terminal Block Torque Rating:Agency Approvals:Product Weight:Product Dimensions (L x W x H):Electromechanical RelayA/CR-DC-5A: 23 to 31.2 VDC, 17 mA @ 24 VDC, 60 HzA/CR-DC-12A: 20 to 31.2 VDC, 17 mA @ 24 VDC, 60 HzA/CR-12DC-12A: 10 to 15.6 VDC, 33.33 mA @ 12 VDC, 60 HzA/CR-24AC-10A: 16 to 26.4 VAC, 28.30 mA @ 24 VAC, 60 Hz or 31.30 mA @ 24 VAC, 50 HzA/CR-115AC-8A: 80 to 132 VAC, 5.35 mA @ 115 VAC, 60 Hz or 5.85 mA @ 115 VAC, 50 HzA/CR-230AC-8A: 165 to 264 VAC, 2.76 mA @ 230 VAC, 60 Hz or 3.00 mA @ 230 VAC, 50 HzForm 1C (SPDT Contact)See Ordering Grid on Back of Data SheetSee Ordering Grid on Back of Data SheetSee Ordering Grid on Back of Data SheetRed LED “On”: Relay Energized “COM to N/O” | Red LED “O”: Relay De-Energized “Com to N/C” > 30,000 Cycles, typical > 10,000,000 Cycles, typical35 mm (U.S. Patent No. 7,416,421)5 to 104ºF (-15 to 40ºC)0 to 95%, non-condensing32 to 104°F (0 to 40°C) | 20% to 85% RH, non-condensingPC/ABS (Polycarbonate/ABS Blend) | UL94-V0Screw Terminal Blocks Relay Coil: 18 to 24 AWG (2.5 mm to 0.20 mm) Copper Wires onlyRelay Contacts: 12 to 16 AWG (4.0 mm to 020 mm) Copper Wires only4.43 to 5.31 in-lbs. (0.5 to 0.6 Nm)UL/CUL US Listed (UL 508) Ind. Control Equipment (File # E179139), CE, RoHS2, WEEEA/CR-DC-5A: 0.135 lbs. (0.061 kg) | A/CR-12DC-12A & A/CR-24AC-10A: 0.150 lbs. (0.068 kg)A/CR-DC-12A, A/CR-115AC-8A & A/CR-230AC-8A: 0.145 lbs. (0.066 kg) 3.283” (83.39 mm) x 1.305” (33.15 mm) x 1.565” (39.75 mm)Automation Components, Inc.CURRENT | COMMAND RELAYCOMMAND RELAYCR SeriesThe Command Relay Series brings control (start/stop) functionality to your load trending and fan/pump/motor status monitoring and control applications. Each unit has a Form 1C - SPDT relay which provides both a Normally-Open “N/O” and a Normally-Closed “N/C” contact in a single device. The patented 35mm Din-Rail mounting ange will allow you to use the A/CR Series with any ACI current sensor or switch that incorporates the 35 mm din rail mounting ange. The stacking feature allows you to reduce the required panel space, since up to two devices may be stacked together during installation and saves cost since two devices can be installed as a single component. An added benet of the A/CR Series command relays separate from the current sensor or switch is that it allows you to mix and match any command relay model with any current sensor or switch model reducing the number of SKU’s needed. All of the command relays can also be used in panel mount applications in place of a typical general purpose relay, since they have been tested to meet the UL 508 Industrial Equipment requirements. Please contact ACI for more information regarding the Command Relays or to discuss your application in further detail.Applications: Start/Stop/Status, Motors, Pumps, Fans, Compressors, Din Rail Mountable Control Relay, Industrial EquipmentThe Command Relays are covered by ACI's Five (5) Year Limited Warranty. The warranty can be found in the front of ACI's Sensors & Transmitters catalog, as well as on ACI's website, www.workaci.com.Note: The LED should not be used to determine if current is presentCURRENT | ## Call: 1-888-967-5224 | Web: www.workaci.com DIMENSIONAL DRAWINGFront ViewRight ViewTop ViewAutomation Components, Inc.CURRENT | COMMAND RELAY2.36” (59.94mm)3.29” (83.56mm)1.61” (40.95mm)2.88” (73.26mm)STANDARD ORDERINGModel #A/CR-DC-5AA/CR-DC-12AA/CR-12DC-12AA/CR-24AC-10AA/CR-115AC-8AA/CR-230AC-8AItem #126773128210129176128214128215128216Nom. Coil Voltage24 VDC24 VDC12 VDC24 VAC115 VAC230 VACMax. Switch Voltage250 VAC, 30 VDC 250 VAC, 30 VDC 250 VAC, 30 VDC 250 VAC, 30 VDC250 VAC, 30 VDC 250 VAC, 30 VDC Max. Switch Current5A (N/O) / 3A (N/C12 Amps12 Amps10 Amps8 Amps8 AmpsContact Rating5A @ 250 VAC* | 5A @ 125 VAC**5A @ 30 VDC** | ¼ HP, 120/250/277 VAC12A @ 250 VAC* | 12A @ 250 VAC** | 12A @ 30 VDC** | 1 HP, 120/240/480 VAC (N/O) | ½ HP, 120/240/480 VAC (N/C)12A @ 250 VAC* | 12A @ 250 VAC** | 12A @ 30 VDC**1 HP, 120/240/480 VAC (N/O) | ½ HP, 120/240/480 VAC (N/C)10A @ 250 VAC* | 10A @ 250 VAC** | 10A @ 30 VDC**1 HP, 120/240/480 VAC (N/O) | ½ HP, 120/240/480 VAC (N/C)8A @ 250 VAC* | 8A @ 250 VAC** | 8A @ 30 VDC*1 HP, 120/240/480 VAC (N/O) | ½ HP, 120/240/480 VAC (N/C)8A @ 250 VAC* | 8A @ 250 VAC** | 8A @ 30 VDC**1 HP, 120/240/480 VAC (N/O) | ½ HP, 120/240/480 VAC (N/C)-OR-Model # Example:A/CR-DC-5A126773Note*: General Use | Note**: ResistiveCURRENT | ## Call: 1-888-967-5224 | Web: www.workaci.com Command Relays are not intended to be used in either Life / Safety Applications or Hazardous / Classied LocationsNext >