Z203391-0D PAGE 1 ©2012 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com 05121Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris ‘V’ logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.TMRELAYSINSTALLATION GUIDE10A SPST Enclosed Relay With HOA SwitchInstaller’s SpecificationsOperating Temperature -40° to 55°C (-40° to 131°F)Operating Humidity 10-90% RH, non-condensingExpected Relay Life Electrical (@ rated current) 100,000 cycles; Mechanical (unpowered) 10,000,000 cyclesRelay Status LED ON=energizedWire Specifications: Lead Length 14” (356mm) min. Gauge UL1015; Coil: 18AWG; Contacts: 16AWGInsulation Class 600VAC RMSAgency Approvals UL508 enclosed device listing, pollution degree 2V101V101DIMENSIONSNOTICE• This product is not intended for life or safety applications.• Do not install this product in hazardous or classified locations.• The installer is responsible for conformance to all applicable codes.• Mount this product inside a suitable fire and electrical enclosure.INSTALLATIONDisconnect and lock out all power sources before beginning the installation.1. Using the threaded nipple, connect the relay to the desired enclosure through a knock out hole.2. Secure with the conduit nut provided.3. Connect coil wires:• Choose the coil common lead (white with yellow stripe) and connect it to the common (-) source termination point.• Choose either the low voltage (10-30VAC/DC, white with blue stripe) or high voltage (120VAC, white with black stripe) lead, depending on the application requirements, and connect it to the (+) source termination point.*NOTE: When connecting the control side of this device (#18 wires) to power line circuits, provide current limiting at 7 amps max.4. Connect relay contacts:• Choose the two orange wires (N.O. contact) and connect to the switched load.5. Secure the enclosure and reconnect power.* Isolate or insulate all non-terminated wires according to local electrical code requirements, i.e. wire nut.2.0"(52 mm)2.5"(64 mm)3/4" NPT Nipple2.3"(59 mm)4.0"(103 mm)3.8"(97 mm)HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH• Follow safe electrical work practices. See NFPA 70E in the USA, or applicable local codes.• This equipment must only be installed and serviced by qualified electrical personnel.• Read, understand and follow the instructions before installing this product.• Turn off all power supplying equipment before working on or inside the equipment.• Use a properly rated voltage sensing device to confirm power is off. DO NOT DEPEND ON THIS PRODUCT FOR VOLTAGE INDICATIONFailure to follow these instructions will result in death or serious injury.DANGER Z203391-0D PAGE 2 ©2012 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com 05121Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris ‘V’ logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.TMV101INSTALLATION GUIDEHOA POSITIONSWIRING EXAMPLENipple mount directly to a panelNipple mount to a 2x or 4x electrical boxTo LoadTo ControlsCOILCONTACTSTo LoadTo ControlsWire NutCOIL CONTACTSWIRING COLOR CODESCONTACT AND COIL SPECIFICATIONSPull in Voltage AC DC10-30V..................................... 8 9120V........................................ 78Drop Out Voltage AC DC10-30V..................................... 2 3120V........................................ 18Voltage Coil Current AC DC10V.......................................... 25mA 14mA24V.......................................... 31mA 16mA30V.......................................... 39mA 18mA120V........................................ 22mA -TYPICAL COIL PERFORMANCECONTACT RATINGSResistive.............. 10A@250VACMotor.................... 1/3HP@120VACGold Flash............. Yes10-30VAC/DC120VACLOWwht/blueCOMMwht/yellowHIwht/blackCONTACT OUTPUTCONTROL SYSTEM INPUTCommonHANDOFFAUTOUp position: contacts are closed.Middle position: contacts are open.Down position: control system actuates the contacts.Next >